Each 2500kVA oil-immersed transformer is carefully inspected, protected and securely fixed before shipment to ensure safe delivery to the project site.
Before dispatch, the manufacturer checks:
Packing and loading photographs can be provided before shipment.
Depending on the transformer’s dimensions, weight, destination and site-access conditions, available transportation methods include:
For oversized units, bushings, radiators, conservators and other vulnerable accessories may be removed and packed separately to reduce transportation height and prevent damage.
The documentation package can include:
Unloading instructions, installation guidance, remote technical support and spare-parts services can also be provided after delivery.
Every 2500kVA oil-immersed transformer undergoes routine testing before shipment. Tests are conducted according to IEC 60076, IEEE C57 or the project’s approved technical specification.
| Routine Test | Purpose |
|---|---|
| Winding Resistance Measurement | Confirms winding continuity, connection quality and resistance balance between phases |
| Voltage-Ratio Measurement | Verifies the designed voltage ratio at every tap position |
| Vector-Group Verification | Confirms polarity, phase sequence and phase displacement |
| Short-Circuit Impedance Measurement | Verifies that the transformer impedance meets the approved design value |
| Load-Loss Measurement | Measures winding and stray losses at the specified reference temperature |
| No-Load Loss Measurement | Determines magnetic-core losses at rated voltage |
| No-Load Current Measurement | Evaluates excitation current and magnetic-core condition |
| Insulation Resistance Test | Checks insulation between HV, LV and earth |
| Applied Voltage Withstand Test | Verifies the main insulation strength between windings and earth |
| Induced Overvoltage Test | Checks inter-turn and inter-layer winding insulation |
| Tap-Changer Functional Test | Confirms correct operation and electrical connections at every tap |
| Transformer Oil Test | Verifies the dielectric strength and condition of the insulating oil |
| Tank Leakage Test | Checks the tank, radiators, valves, welds and gaskets for leakage |
| Accessory Functional Test | Verifies indicators, relays, cooling equipment and alarm contacts |
| Earthing Continuity Test | Confirms reliable transformer grounding connections |
| Visual and Dimensional Inspection | Checks dimensions, terminals, nameplate, paint finish and accessories |
A complete routine test report can be supplied before shipment. Type and special tests—including temperature-rise, lightning-impulse, sound-level and partial-discharge tests—are available when specified by the customer.
The 2500kVA oil-immersed transformer is designed for medium-voltage power distribution in utility, industrial, commercial and renewable energy systems. Its 2.5MVA capacity makes it suitable for large facilities with continuous, concentrated or fluctuating electrical loads.
Suitable for:
Provides stable power for:
The transformer can be customized for:
Special designs are available for harmonic loads, bidirectional power flow, voltage fluctuations and high ambient temperatures.
Suitable for:
Reinforced windings, enhanced cooling and heavy-duty corrosion protection can be provided for harsh operating environments.
Applicable to:
C4 or C5 anti-corrosion systems are available for coastal and chemically aggressive environments.
Provides reliable power distribution for:
Suitable for municipal facilities, water-treatment plants, ports, railway systems, transportation hubs and major construction projects.
The transformer can be engineered according to project-specific voltage ratios, vector groups, impedance, efficiency targets, installation environments and protection requirements.
Typical configurations include:
Other voltage combinations are available according to the local grid and project design.