{"id":1648,"date":"2026-08-03T10:25:40","date_gmt":"2026-08-03T02:25:40","guid":{"rendered":"https:\/\/www.zishengelectric.com\/?post_type=product&#038;p=1648"},"modified":"2026-08-03T10:25:41","modified_gmt":"2026-08-03T02:25:41","slug":"630kva-three-phase-oil-immersed-outdoor-substation-transformer-220v-to-380v-step-up-transformer","status":"publish","type":"product","link":"https:\/\/www.zishengelectric.com\/ar\/product\/630kva-three-phase-oil-immersed-outdoor-substation-transformer-220v-to-380v-step-up-transformer","title":{"rendered":"630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer | 220V to 380V Step-Up Transformer"},"content":{"rendered":"<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"mejz8x\" data-start=\"131\" data-end=\"152\">1. Product Overview<\/h1>\n<p data-start=\"154\" data-end=\"403\">ZISHENG <strong data-start=\"162\" data-end=\"228\">630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer<\/strong> is a high-performance power distribution transformer designed for outdoor substations, industrial power systems, renewable energy projects, and utility distribution networks.<\/p>\n<p data-start=\"405\" data-end=\"611\">With a rated capacity of <strong data-start=\"430\" data-end=\"440\">630kVA<\/strong>, this transformer is engineered to provide reliable voltage conversion between 220V and 380V systems, ensuring stable and efficient power supply for various applications.<\/p>\n<p data-start=\"613\" data-end=\"867\">The transformer adopts high-quality transformer oil as the insulation and cooling medium. The oil immersed design provides excellent heat dissipation, strong insulation capability, high overload resistance, and reliable operation in outdoor environments.<\/p>\n<p data-start=\"869\" data-end=\"1037\">Manufactured with advanced production technology, premium electrical materials, and strict quality control procedures, ZISHENG 630kVA Oil Immersed Transformer features:<\/p>\n<ul data-start=\"1039\" data-end=\"1222\">\n<li data-section-id=\"3boosz\" data-start=\"1039\" data-end=\"1063\">High energy efficiency<\/li>\n<li data-section-id=\"1rh0ffk\" data-start=\"1064\" data-end=\"1080\">Low power loss<\/li>\n<li data-section-id=\"1bn4qno\" data-start=\"1081\" data-end=\"1114\">Strong short-circuit resistance<\/li>\n<li data-section-id=\"1vea2vo\" data-start=\"1115\" data-end=\"1146\">Excellent overload capability<\/li>\n<li data-section-id=\"4eiwjk\" data-start=\"1147\" data-end=\"1202\">Stable operation under harsh environmental conditions<\/li>\n<li data-section-id=\"1wdzf4p\" data-start=\"1203\" data-end=\"1222\">Long service life<\/li>\n<\/ul>\n<p data-start=\"1224\" data-end=\"1248\">It is widely applied in:<\/p>\n<ul data-start=\"1250\" data-end=\"1427\">\n<li data-section-id=\"ll2ev1\" data-start=\"1250\" data-end=\"1271\">Outdoor substations<\/li>\n<li data-section-id=\"42f3ho\" data-start=\"1272\" data-end=\"1295\">Industrial facilities<\/li>\n<li data-section-id=\"lu0giz\" data-start=\"1296\" data-end=\"1325\">Solar photovoltaic projects<\/li>\n<li data-section-id=\"1cx3e7b\" data-start=\"1326\" data-end=\"1365\">Commercial power distribution systems<\/li>\n<li data-section-id=\"18del2g\" data-start=\"1366\" data-end=\"1402\">Mining and infrastructure projects<\/li>\n<li data-section-id=\"1xwmdbu\" data-start=\"1403\" data-end=\"1427\">Utility power networks<\/li>\n<\/ul>\n<hr data-start=\"1429\" data-end=\"1432\" \/>\n<h1 data-section-id=\"1c1ddwf\" data-start=\"1434\" data-end=\"1461\">2. Product Specifications<\/h1>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1463\" data-end=\"2285\">\n<thead data-start=\"1463\" data-end=\"1492\">\n<tr data-start=\"1463\" data-end=\"1492\">\n<th class=\"last:pe-10\" data-start=\"1463\" data-end=\"1475\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"1475\" data-end=\"1492\" data-col-size=\"md\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1503\" data-end=\"2285\">\n<tr data-start=\"1503\" data-end=\"1584\">\n<td data-start=\"1503\" data-end=\"1518\" data-col-size=\"sm\">Product Name<\/td>\n<td data-start=\"1518\" data-end=\"1584\" data-col-size=\"md\">630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer<\/td>\n<\/tr>\n<tr data-start=\"1585\" data-end=\"1612\">\n<td data-start=\"1585\" data-end=\"1602\" data-col-size=\"sm\">Rated Capacity<\/td>\n<td data-start=\"1602\" data-end=\"1612\" data-col-size=\"md\">630kVA<\/td>\n<\/tr>\n<tr data-start=\"1613\" data-end=\"1673\">\n<td data-start=\"1613\" data-end=\"1632\" data-col-size=\"sm\">Transformer Type<\/td>\n<td data-start=\"1632\" data-end=\"1673\" data-col-size=\"md\">Oil Immersed Distribution Transformer<\/td>\n<\/tr>\n<tr data-start=\"1674\" data-end=\"1697\">\n<td data-start=\"1674\" data-end=\"1682\" data-col-size=\"sm\">Phase<\/td>\n<td data-start=\"1682\" data-end=\"1697\" data-col-size=\"md\">Three Phase<\/td>\n<\/tr>\n<tr data-start=\"1698\" data-end=\"1755\">\n<td data-start=\"1698\" data-end=\"1712\" data-col-size=\"sm\">Application<\/td>\n<td data-start=\"1712\" data-end=\"1755\" data-col-size=\"md\">Outdoor Substation \/ Power Distribution<\/td>\n<\/tr>\n<tr data-start=\"1756\" data-end=\"1800\">\n<td data-start=\"1756\" data-end=\"1772\" data-col-size=\"sm\">Voltage Ratio<\/td>\n<td data-start=\"1772\" data-end=\"1800\" data-col-size=\"md\">220V \/ 380V (Customized)<\/td>\n<\/tr>\n<tr data-start=\"1801\" data-end=\"1828\">\n<td data-start=\"1801\" data-end=\"1813\" data-col-size=\"sm\">Frequency<\/td>\n<td data-start=\"1813\" data-end=\"1828\" data-col-size=\"md\">50Hz \/ 60Hz<\/td>\n<\/tr>\n<tr data-start=\"1829\" data-end=\"1863\">\n<td data-start=\"1829\" data-end=\"1849\" data-col-size=\"sm\">High Voltage Side<\/td>\n<td data-start=\"1849\" data-end=\"1863\" data-col-size=\"md\">Customized<\/td>\n<\/tr>\n<tr data-start=\"1864\" data-end=\"1897\">\n<td data-start=\"1864\" data-end=\"1883\" data-col-size=\"sm\">Low Voltage Side<\/td>\n<td data-start=\"1883\" data-end=\"1897\" data-col-size=\"md\">Customized<\/td>\n<\/tr>\n<tr data-start=\"1898\" data-end=\"1949\">\n<td data-start=\"1898\" data-end=\"1915\" data-col-size=\"sm\">Cooling Method<\/td>\n<td data-start=\"1915\" data-end=\"1949\" data-col-size=\"md\">ONAN (Oil Natural Air Natural)<\/td>\n<\/tr>\n<tr data-start=\"1950\" data-end=\"1990\">\n<td data-start=\"1950\" data-end=\"1969\" data-col-size=\"sm\">Winding Material<\/td>\n<td data-start=\"1969\" data-end=\"1990\" data-col-size=\"md\">Copper \/ Aluminum<\/td>\n<\/tr>\n<tr data-start=\"1991\" data-end=\"2039\">\n<td data-start=\"1991\" data-end=\"2007\" data-col-size=\"sm\">Core Material<\/td>\n<td data-start=\"2007\" data-end=\"2039\" data-col-size=\"md\">Grain-Oriented Silicon Steel<\/td>\n<\/tr>\n<tr data-start=\"2040\" data-end=\"2079\">\n<td data-start=\"2040\" data-end=\"2060\" data-col-size=\"sm\">Insulation Medium<\/td>\n<td data-start=\"2060\" data-end=\"2079\" data-col-size=\"md\">Transformer Oil<\/td>\n<\/tr>\n<tr data-start=\"2080\" data-end=\"2111\">\n<td data-start=\"2080\" data-end=\"2100\" data-col-size=\"sm\">Installation Type<\/td>\n<td data-start=\"2100\" data-end=\"2111\" data-col-size=\"md\">Outdoor<\/td>\n<\/tr>\n<tr data-start=\"2112\" data-end=\"2153\">\n<td data-start=\"2112\" data-end=\"2126\" data-col-size=\"sm\">Tap Changer<\/td>\n<td data-start=\"2126\" data-end=\"2153\" data-col-size=\"md\">Off-Circuit Tap Changer<\/td>\n<\/tr>\n<tr data-start=\"2154\" data-end=\"2200\">\n<td data-start=\"2154\" data-end=\"2166\" data-col-size=\"sm\">Tank Type<\/td>\n<td data-start=\"2166\" data-end=\"2200\" data-col-size=\"md\">Sealed Tank \/ Conservator Type<\/td>\n<\/tr>\n<tr data-start=\"2201\" data-end=\"2234\">\n<td data-start=\"2201\" data-end=\"2220\" data-col-size=\"sm\">Protection Level<\/td>\n<td data-start=\"2220\" data-end=\"2234\" data-col-size=\"md\">Customized<\/td>\n<\/tr>\n<tr data-start=\"2235\" data-end=\"2285\">\n<td data-start=\"2235\" data-end=\"2247\" data-col-size=\"sm\">Standards<\/td>\n<td data-start=\"2247\" data-end=\"2285\" data-col-size=\"md\">IEC \/ ANSI \/ Customer Requirements<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"2287\" data-end=\"2290\" \/>\n<h1 data-section-id=\"15sho5z\" data-start=\"2292\" data-end=\"2318\">3. Main Structure Design<\/h1>\n<h2 data-section-id=\"144kq1c\" data-start=\"2320\" data-end=\"2361\">3.1 High-Efficiency Silicon Steel Core<\/h2>\n<p data-start=\"2363\" data-end=\"2479\">The 630kVA transformer uses high-quality grain-oriented silicon steel sheets with optimized magnetic circuit design.<\/p>\n<h3 data-section-id=\"11jdyw4\" data-start=\"2481\" data-end=\"2496\">Advantages:<\/h3>\n<ul data-start=\"2498\" data-end=\"2659\">\n<li data-section-id=\"1mc7dlh\" data-start=\"2498\" data-end=\"2516\">Low no-load loss<\/li>\n<li data-section-id=\"1uqoc6z\" data-start=\"2517\" data-end=\"2545\">Reduced excitation current<\/li>\n<li data-section-id=\"1kh8air\" data-start=\"2546\" data-end=\"2574\">Improved energy efficiency<\/li>\n<li data-section-id=\"1mgzs9m\" data-start=\"2575\" data-end=\"2604\">Lower operating temperature<\/li>\n<li data-section-id=\"1dy14x6\" data-start=\"2605\" data-end=\"2636\">Reduced electromagnetic noise<\/li>\n<li data-section-id=\"65tuqe\" data-start=\"2637\" data-end=\"2659\">Enhanced reliability<\/li>\n<\/ul>\n<p data-start=\"2661\" data-end=\"2788\">The advanced core structure reduces energy consumption during long-term operation and improves overall transformer performance.<\/p>\n<hr data-start=\"2790\" data-end=\"2793\" \/>\n<h1 data-section-id=\"1qcvz3m\" data-start=\"2795\" data-end=\"2841\">3.2 High-Strength Three-Phase Winding System<\/h1>\n<p data-start=\"2843\" data-end=\"2964\">The transformer adopts high-quality copper or aluminum windings designed for three-phase power distribution applications.<\/p>\n<h3 data-section-id=\"q4c1cr\" data-start=\"2966\" data-end=\"2979\">Features:<\/h3>\n<ul data-start=\"2981\" data-end=\"3148\">\n<li data-section-id=\"1kf79r1\" data-start=\"2981\" data-end=\"3016\">Excellent electrical conductivity<\/li>\n<li data-section-id=\"5kwhp1\" data-start=\"3017\" data-end=\"3045\">Strong mechanical strength<\/li>\n<li data-section-id=\"1jhpe4o\" data-start=\"3046\" data-end=\"3070\">High thermal stability<\/li>\n<li data-section-id=\"1s3mqhk\" data-start=\"3071\" data-end=\"3104\">Reliable insulation performance<\/li>\n<li data-section-id=\"1nuwa3t\" data-start=\"3105\" data-end=\"3148\">Strong short-circuit withstand capability<\/li>\n<\/ul>\n<p data-start=\"3150\" data-end=\"3249\">The optimized winding structure ensures stable operation under normal and abnormal load conditions.<\/p>\n<hr data-start=\"3251\" data-end=\"3254\" \/>\n<h1 data-section-id=\"hst25v\" data-start=\"3256\" data-end=\"3292\">3.3 Transformer Oil Cooling System<\/h1>\n<p data-start=\"3294\" data-end=\"3380\">The transformer uses high-quality insulating oil as the cooling and insulation medium.<\/p>\n<h3 data-section-id=\"39hpnx\" data-start=\"3382\" data-end=\"3396\">Functions:<\/h3>\n<ul data-start=\"3398\" data-end=\"3565\">\n<li data-section-id=\"1gu9yf9\" data-start=\"3398\" data-end=\"3439\">Transfers heat from internal components<\/li>\n<li data-section-id=\"1rwqrbq\" data-start=\"3440\" data-end=\"3472\">Provides electrical insulation<\/li>\n<li data-section-id=\"13so5m2\" data-start=\"3473\" data-end=\"3504\">Reduces operating temperature<\/li>\n<li data-section-id=\"wu9e0p\" data-start=\"3505\" data-end=\"3535\">Improves overload capability<\/li>\n<li data-section-id=\"3sibvr\" data-start=\"3536\" data-end=\"3565\">Extends insulation lifespan<\/li>\n<\/ul>\n<p data-start=\"3567\" data-end=\"3655\">The ONAN cooling system enables reliable operation without additional cooling equipment.<\/p>\n<hr data-start=\"3657\" data-end=\"3660\" \/>\n<h1 data-section-id=\"zaq09d\" data-start=\"3662\" data-end=\"3702\">3.4 Durable Outdoor Oil Tank Structure<\/h1>\n<p data-start=\"3704\" data-end=\"3814\">The transformer tank is designed for outdoor installation and manufactured with high-strength steel materials.<\/p>\n<h3 data-section-id=\"q4c1cr\" data-start=\"3816\" data-end=\"3829\">Features:<\/h3>\n<ul data-start=\"3831\" data-end=\"3951\">\n<li data-section-id=\"6nir7i\" data-start=\"3831\" data-end=\"3857\">Weather-resistant design<\/li>\n<li data-section-id=\"1u5w4v5\" data-start=\"3858\" data-end=\"3880\">Reliable oil sealing<\/li>\n<li data-section-id=\"1g9fqrp\" data-start=\"3881\" data-end=\"3902\">Moisture protection<\/li>\n<li data-section-id=\"1hdrbrx\" data-start=\"3903\" data-end=\"3920\">Dust resistance<\/li>\n<li data-section-id=\"akizqp\" data-start=\"3921\" data-end=\"3951\">Strong mechanical durability<\/li>\n<\/ul>\n<p data-start=\"3953\" data-end=\"3980\">It can operate reliably in:<\/p>\n<ul data-start=\"3982\" data-end=\"4079\">\n<li data-section-id=\"ofhcwx\" data-start=\"3982\" data-end=\"4013\">High-temperature environments<\/li>\n<li data-section-id=\"evncri\" data-start=\"4014\" data-end=\"4033\">Tropical climates<\/li>\n<li data-section-id=\"9sbtfd\" data-start=\"4034\" data-end=\"4057\">High-humidity regions<\/li>\n<li data-section-id=\"ll2ev1\" data-start=\"4058\" data-end=\"4079\">Outdoor substations<\/li>\n<\/ul>\n<hr data-start=\"4081\" data-end=\"4084\" \/>\n<h1 data-section-id=\"9j231r\" data-start=\"4086\" data-end=\"4109\">4. Product Advantages<\/h1>\n<h2 data-section-id=\"1i2qvvn\" data-start=\"4111\" data-end=\"4153\">Reliable Outdoor Substation Performance<\/h2>\n<p data-start=\"4155\" data-end=\"4260\">The 630kVA Oil Immersed Transformer is specifically designed for outdoor power distribution applications.<\/p>\n<p data-start=\"4262\" data-end=\"4273\">Advantages:<\/p>\n<ul data-start=\"4275\" data-end=\"4395\">\n<li data-section-id=\"1nuufxb\" data-start=\"4275\" data-end=\"4302\">Stable voltage conversion<\/li>\n<li data-section-id=\"1fkg8uh\" data-start=\"4303\" data-end=\"4328\">Continuous power supply<\/li>\n<li data-section-id=\"1d06lnl\" data-start=\"4329\" data-end=\"4364\">Strong environmental adaptability<\/li>\n<li data-section-id=\"1a13qek\" data-start=\"4365\" data-end=\"4395\">Long-term reliable operation<\/li>\n<\/ul>\n<hr data-start=\"4397\" data-end=\"4400\" \/>\n<h2 data-section-id=\"1ial9zy\" data-start=\"4402\" data-end=\"4427\">High Energy Efficiency<\/h2>\n<p data-start=\"4429\" data-end=\"4506\">The transformer uses low-loss materials and optimized electromagnetic design.<\/p>\n<p data-start=\"4508\" data-end=\"4517\">Benefits:<\/p>\n<ul data-start=\"4519\" data-end=\"4626\">\n<li data-section-id=\"8jcomg\" data-start=\"4519\" data-end=\"4545\">Reduced electricity loss<\/li>\n<li data-section-id=\"df4632\" data-start=\"4546\" data-end=\"4569\">Lower operating costs<\/li>\n<li data-section-id=\"1gwqwny\" data-start=\"4570\" data-end=\"4599\">Improved energy utilization<\/li>\n<li data-section-id=\"16zs9z9\" data-start=\"4600\" data-end=\"4626\">Reduced carbon emissions<\/li>\n<\/ul>\n<hr data-start=\"4628\" data-end=\"4631\" \/>\n<h2 data-section-id=\"1c3kvqo\" data-start=\"4633\" data-end=\"4662\">Excellent Heat Dissipation<\/h2>\n<p data-start=\"4664\" data-end=\"4734\">The oil immersed cooling system effectively removes heat generated by:<\/p>\n<ul data-start=\"4736\" data-end=\"4791\">\n<li data-section-id=\"1hlb2fd\" data-start=\"4736\" data-end=\"4747\">Iron core<\/li>\n<li data-section-id=\"vlusrz\" data-start=\"4748\" data-end=\"4758\">Windings<\/li>\n<li data-section-id=\"100pqzh\" data-start=\"4759\" data-end=\"4791\">Internal electrical components<\/li>\n<\/ul>\n<p data-start=\"4793\" data-end=\"4802\">Benefits:<\/p>\n<ul data-start=\"4804\" data-end=\"4888\">\n<li data-section-id=\"182l81a\" data-start=\"4804\" data-end=\"4832\">Stable temperature control<\/li>\n<li data-section-id=\"23gszk\" data-start=\"4833\" data-end=\"4859\">Improved insulation life<\/li>\n<li data-section-id=\"svsork\" data-start=\"4860\" data-end=\"4888\">Better overload capability<\/li>\n<\/ul>\n<hr data-start=\"4890\" data-end=\"4893\" \/>\n<h2 data-section-id=\"kwluum\" data-start=\"4895\" data-end=\"4924\">Strong Overload Capability<\/h2>\n<p data-start=\"4926\" data-end=\"5045\">The reinforced structure and efficient cooling system allow the transformer to withstand temporary overload conditions.<\/p>\n<p data-start=\"5047\" data-end=\"5078\">Suitable for applications with:<\/p>\n<ul data-start=\"5080\" data-end=\"5168\">\n<li data-section-id=\"p2kd2y\" data-start=\"5080\" data-end=\"5110\">Industrial load fluctuations<\/li>\n<li data-section-id=\"1tjxdb\" data-start=\"5111\" data-end=\"5130\">Peak power demand<\/li>\n<li data-section-id=\"lnhwpk\" data-start=\"5131\" data-end=\"5168\">Renewable energy generation changes<\/li>\n<\/ul>\n<hr data-start=\"5170\" data-end=\"5173\" \/>\n<h2 data-section-id=\"1aujk67\" data-start=\"5175\" data-end=\"5211\">Superior Short-Circuit Resistance<\/h2>\n<p data-start=\"5213\" data-end=\"5317\">The reinforced winding structure improves resistance against mechanical forces caused by short circuits.<\/p>\n<p data-start=\"5319\" data-end=\"5328\">Benefits:<\/p>\n<ul data-start=\"5330\" data-end=\"5403\">\n<li data-section-id=\"sx3yga\" data-start=\"5330\" data-end=\"5347\">Improved safety<\/li>\n<li data-section-id=\"1hiwwdr\" data-start=\"5348\" data-end=\"5370\">Reduced failure risk<\/li>\n<li data-section-id=\"1gvfc49\" data-start=\"5371\" data-end=\"5403\">Higher operational reliability<\/li>\n<\/ul>\n<hr data-start=\"5405\" data-end=\"5408\" \/>\n<h1 data-section-id=\"194sy77\" data-start=\"5410\" data-end=\"5432\">5. Application Areas<\/h1>\n<h2 data-section-id=\"oamsmo\" data-start=\"5434\" data-end=\"5456\">Outdoor Substations<\/h2>\n<ul data-start=\"5458\" data-end=\"5532\">\n<li data-section-id=\"p1b3xh\" data-start=\"5458\" data-end=\"5479\">Utility substations<\/li>\n<li data-section-id=\"iknvhb\" data-start=\"5480\" data-end=\"5506\">Distribution substations<\/li>\n<li data-section-id=\"rcv2u2\" data-start=\"5507\" data-end=\"5532\">Medium voltage networks<\/li>\n<\/ul>\n<h2 data-section-id=\"k2nesr\" data-start=\"5534\" data-end=\"5561\">Industrial Power Systems<\/h2>\n<ul data-start=\"5563\" data-end=\"5652\">\n<li data-section-id=\"1wxr1zu\" data-start=\"5563\" data-end=\"5588\">Manufacturing factories<\/li>\n<li data-section-id=\"w4ylc4\" data-start=\"5589\" data-end=\"5608\">Mining operations<\/li>\n<li data-section-id=\"109rian\" data-start=\"5609\" data-end=\"5633\">Oil and gas facilities<\/li>\n<li data-section-id=\"19k8p10\" data-start=\"5634\" data-end=\"5652\">Industrial parks<\/li>\n<\/ul>\n<h2 data-section-id=\"lg5s3k\" data-start=\"5654\" data-end=\"5682\">Renewable Energy Projects<\/h2>\n<ul data-start=\"5684\" data-end=\"5747\">\n<li data-section-id=\"3sce6x\" data-start=\"5684\" data-end=\"5701\">Solar PV plants<\/li>\n<li data-section-id=\"elqwfr\" data-start=\"5702\" data-end=\"5714\">Wind farms<\/li>\n<li data-section-id=\"1j6rweg\" data-start=\"5715\" data-end=\"5747\">Battery energy storage systems<\/li>\n<\/ul>\n<h2 data-section-id=\"r8igu6\" data-start=\"5749\" data-end=\"5777\">Commercial Infrastructure<\/h2>\n<ul data-start=\"5779\" data-end=\"5868\">\n<li data-section-id=\"1k2bjz8\" data-start=\"5779\" data-end=\"5797\">Shopping centers<\/li>\n<li data-section-id=\"1xm3l8e\" data-start=\"5798\" data-end=\"5816\">Office complexes<\/li>\n<li data-section-id=\"19i90un\" data-start=\"5817\" data-end=\"5842\">Residential communities<\/li>\n<li data-section-id=\"nrp7g7\" data-start=\"5843\" data-end=\"5868\">Large public facilities<\/li>\n<\/ul>\n<h2 data-section-id=\"1tboisf\" data-start=\"5870\" data-end=\"5909\">Agricultural and Remote Power Supply<\/h2>\n<ul data-start=\"5911\" data-end=\"5986\">\n<li data-section-id=\"1dkif29\" data-start=\"5911\" data-end=\"5934\">Rural electrification<\/li>\n<li data-section-id=\"19l70vx\" data-start=\"5935\" data-end=\"5968\">Agricultural irrigation systems<\/li>\n<li data-section-id=\"1jskyf7\" data-start=\"5969\" data-end=\"5986\">Remote villages<\/li>\n<\/ul>\n<hr data-start=\"5988\" data-end=\"5991\" \/>\n<h1 data-section-id=\"1fzcoge\" data-start=\"5993\" data-end=\"6041\">6. 220V to 380V Voltage Conversion Application<\/h1>\n<p data-start=\"6043\" data-end=\"6155\">The 630kVA transformer can be configured for 220V to 380V voltage conversion according to customer requirements.<\/p>\n<h3 data-section-id=\"7gqqgf\" data-start=\"6157\" data-end=\"6182\">Typical Applications:<\/h3>\n<ul data-start=\"6184\" data-end=\"6322\">\n<li data-section-id=\"xi18v8\" data-start=\"6184\" data-end=\"6219\">Low-voltage distribution networks<\/li>\n<li data-section-id=\"1q051e1\" data-start=\"6220\" data-end=\"6255\">Industrial equipment power supply<\/li>\n<li data-section-id=\"7xuclo\" data-start=\"6256\" data-end=\"6287\">Commercial electrical systems<\/li>\n<li data-section-id=\"1hezcrl\" data-start=\"6288\" data-end=\"6322\">Rural power improvement projects<\/li>\n<\/ul>\n<h3 data-section-id=\"1iaul7c\" data-start=\"6324\" data-end=\"6337\">Benefits:<\/h3>\n<ul data-start=\"6339\" data-end=\"6461\">\n<li data-section-id=\"4tazo8\" data-start=\"6339\" data-end=\"6362\">Stable voltage output<\/li>\n<li data-section-id=\"ku0q9w\" data-start=\"6363\" data-end=\"6387\">Improved power quality<\/li>\n<li data-section-id=\"1xwof0\" data-start=\"6388\" data-end=\"6429\">Suitable for different electrical loads<\/li>\n<li data-section-id=\"21nb1t\" data-start=\"6430\" data-end=\"6461\">Flexible installation options<\/li>\n<\/ul>\n<hr data-start=\"6463\" data-end=\"6466\" \/>\n<h1 data-section-id=\"1xk0c42\" data-start=\"6468\" data-end=\"6494\">7. Customization Options<\/h1>\n<p data-start=\"6496\" data-end=\"6576\">ZISHENG provides customized transformer solutions based on project requirements.<\/p>\n<p data-start=\"6578\" data-end=\"6596\">Available options:<\/p>\n<ul data-start=\"6598\" data-end=\"6857\">\n<li data-section-id=\"17csz12\" data-start=\"6598\" data-end=\"6627\">Voltage ratio customization<\/li>\n<li data-section-id=\"q1lkw0\" data-start=\"6628\" data-end=\"6651\">50Hz \/ 60Hz frequency<\/li>\n<li data-section-id=\"12hyp68\" data-start=\"6652\" data-end=\"6680\">Copper or aluminum winding<\/li>\n<li data-section-id=\"h26f0u\" data-start=\"6681\" data-end=\"6705\">Vector group selection<\/li>\n<li data-section-id=\"7bge9n\" data-start=\"6706\" data-end=\"6728\">Impedance adjustment<\/li>\n<li data-section-id=\"1dsxl1l\" data-start=\"6729\" data-end=\"6756\">Tap changer configuration<\/li>\n<li data-section-id=\"1bfai1j\" data-start=\"6757\" data-end=\"6784\">Tank design customization<\/li>\n<li data-section-id=\"1n34aaa\" data-start=\"6785\" data-end=\"6819\">Special environmental protection<\/li>\n<li data-section-id=\"ods9p\" data-start=\"6820\" data-end=\"6857\">Different installation requirements<\/li>\n<\/ul>\n<p data-start=\"6859\" data-end=\"6880\">Optional accessories:<\/p>\n<ul data-start=\"6882\" data-end=\"7036\">\n<li data-section-id=\"1axeqkv\" data-start=\"6882\" data-end=\"6909\">Oil temperature indicator<\/li>\n<li data-section-id=\"1gthgs5\" data-start=\"6910\" data-end=\"6931\">Oil level indicator<\/li>\n<li data-section-id=\"muahk4\" data-start=\"6932\" data-end=\"6956\">Pressure relief device<\/li>\n<li data-section-id=\"1lhq24s\" data-start=\"6957\" data-end=\"6977\">Lightning arrester<\/li>\n<li data-section-id=\"fewx34\" data-start=\"6978\" data-end=\"6996\">Conservator tank<\/li>\n<li data-section-id=\"1embb6u\" data-start=\"6997\" data-end=\"7013\">Buchholz relay<\/li>\n<li data-section-id=\"j6qyn7\" data-start=\"7014\" data-end=\"7036\">Protective enclosure<\/li>\n<\/ul>\n<hr data-start=\"7038\" data-end=\"7041\" \/>\n<h1 data-section-id=\"6x7t4q\" data-start=\"7043\" data-end=\"7089\">8. Manufacturing Process and Quality Control<\/h1>\n<p data-start=\"7091\" data-end=\"7155\">ZISHENG follows strict quality management throughout production.<\/p>\n<h2 data-section-id=\"1hamono\" data-start=\"7157\" data-end=\"7183\">Raw Material Inspection<\/h2>\n<p data-start=\"7185\" data-end=\"7195\">Including:<\/p>\n<ul data-start=\"7197\" data-end=\"7320\">\n<li data-section-id=\"mebhu7\" data-start=\"7197\" data-end=\"7229\">Silicon steel sheet inspection<\/li>\n<li data-section-id=\"1h6cx7o\" data-start=\"7230\" data-end=\"7261\">Conductor material inspection<\/li>\n<li data-section-id=\"z21j9p\" data-start=\"7262\" data-end=\"7294\">Insulation material inspection<\/li>\n<li data-section-id=\"jbjaxb\" data-start=\"7295\" data-end=\"7320\">Transformer oil testing<\/li>\n<\/ul>\n<hr data-start=\"7322\" data-end=\"7325\" \/>\n<h2 data-section-id=\"1295219\" data-start=\"7327\" data-end=\"7348\">Production Process<\/h2>\n<p data-start=\"7350\" data-end=\"7360\">Including:<\/p>\n<ul data-start=\"7362\" data-end=\"7486\">\n<li data-section-id=\"s68ls\" data-start=\"7362\" data-end=\"7389\">Core cutting and assembly<\/li>\n<li data-section-id=\"16zubjp\" data-start=\"7390\" data-end=\"7404\">Coil winding<\/li>\n<li data-section-id=\"kqb0jg\" data-start=\"7405\" data-end=\"7427\">Insulation treatment<\/li>\n<li data-section-id=\"1ia3dil\" data-start=\"7428\" data-end=\"7450\">Transformer assembly<\/li>\n<li data-section-id=\"2xp1ia\" data-start=\"7451\" data-end=\"7465\">Tank welding<\/li>\n<li data-section-id=\"14q153o\" data-start=\"7466\" data-end=\"7486\">Vacuum oil filling<\/li>\n<\/ul>\n<hr data-start=\"7488\" data-end=\"7491\" \/>\n<h2 data-section-id=\"opu6e7\" data-start=\"7493\" data-end=\"7509\">Final Testing<\/h2>\n<p data-start=\"7511\" data-end=\"7566\">Each 630kVA transformer undergoes professional testing:<\/p>\n<ul data-start=\"7568\" data-end=\"7767\">\n<li data-section-id=\"13jcszt\" data-start=\"7568\" data-end=\"7593\">Winding resistance test<\/li>\n<li data-section-id=\"19g9fot\" data-start=\"7594\" data-end=\"7622\">Insulation resistance test<\/li>\n<li data-section-id=\"gu8nj1\" data-start=\"7623\" data-end=\"7643\">Voltage ratio test<\/li>\n<li data-section-id=\"1lot3kn\" data-start=\"7644\" data-end=\"7663\">No-load loss test<\/li>\n<li data-section-id=\"9opfkr\" data-start=\"7664\" data-end=\"7680\">Load loss test<\/li>\n<li data-section-id=\"i83fx1\" data-start=\"7681\" data-end=\"7707\">Dielectric strength test<\/li>\n<li data-section-id=\"f88wac\" data-start=\"7708\" data-end=\"7726\">Oil leakage test<\/li>\n<li data-section-id=\"kgl4dh\" data-start=\"7727\" data-end=\"7767\">Short-circuit performance verification<\/li>\n<\/ul>\n<p data-start=\"7769\" data-end=\"7819\">Only qualified products are approved for delivery.<\/p>\n<hr data-start=\"7821\" data-end=\"7824\" \/>\n<h1 data-section-id=\"84j0fv\" data-start=\"7826\" data-end=\"7893\">9. Why Choose ZISHENG 630kVA Three-Phase Oil-Immersed Transformer<\/h1>\n<ul data-start=\"7895\" data-end=\"8298\">\n<li data-section-id=\"15fefe7\" data-start=\"7895\" data-end=\"7934\">Professional transformer manufacturer<\/li>\n<li data-section-id=\"oe63nq\" data-start=\"7935\" data-end=\"7962\">Multiple production lines<\/li>\n<li data-section-id=\"19mrpe8\" data-start=\"7963\" data-end=\"7998\">Advanced manufacturing technology<\/li>\n<li data-section-id=\"1a3jn00\" data-start=\"7999\" data-end=\"8034\">High-quality electrical materials<\/li>\n<li data-section-id=\"drxkcs\" data-start=\"8035\" data-end=\"8066\">Strict quality control system<\/li>\n<li data-section-id=\"eb3ucz\" data-start=\"8067\" data-end=\"8103\">Competitive factory-direct pricing<\/li>\n<li data-section-id=\"1tua26y\" data-start=\"8104\" data-end=\"8138\">Customized engineering solutions<\/li>\n<li data-section-id=\"xqt2c2\" data-start=\"8139\" data-end=\"8167\">Stable production capacity<\/li>\n<li data-section-id=\"7qao7w\" data-start=\"8168\" data-end=\"8198\">Reliable delivery capability<\/li>\n<li data-section-id=\"1ljnp2h\" data-start=\"8199\" data-end=\"8298\">Export experience in Africa, South America, Southeast Asia, Central Asia, and Middle East markets<\/li>\n<\/ul>\n<p data-start=\"8300\" data-end=\"8623\" data-is-last-node=\"\" data-is-only-node=\"\">ZISHENG <strong data-start=\"8308\" data-end=\"8409\">630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer | 220V to 380V Step-Up Transformer<\/strong> provides a reliable, efficient, and durable power distribution solution for utility companies, EPC contractors, industrial enterprises, renewable energy developers, and electrical equipment distributors worldwide.<\/p>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"ogo6eg\" data-start=\"0\" data-end=\"76\">630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer Product Q&amp;A<\/h1>\n<h2 data-section-id=\"m93ev6\" data-start=\"78\" data-end=\"158\">Q1: What is a 630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer?<\/h2>\n<p data-start=\"160\" data-end=\"335\"><strong data-start=\"160\" data-end=\"166\">A:<\/strong> A 630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer is a power distribution transformer designed for outdoor substations and medium-voltage power networks.<\/p>\n<p data-start=\"337\" data-end=\"579\">With a rated capacity of 630kVA, it converts electrical energy between different voltage levels, such as 220V and 380V systems, providing stable and reliable power supply for industrial, commercial, renewable energy, and utility applications.<\/p>\n<p data-start=\"581\" data-end=\"762\">The transformer uses transformer oil as both the insulation and cooling medium, ensuring excellent heat dissipation, reliable insulation performance, and long-term stable operation.<\/p>\n<hr data-start=\"764\" data-end=\"767\" \/>\n<h2 data-section-id=\"1th363o\" data-start=\"769\" data-end=\"842\">Q2: What are the main advantages of a 630kVA Oil-Immersed Transformer?<\/h2>\n<p data-start=\"844\" data-end=\"879\"><strong data-start=\"844\" data-end=\"850\">A:<\/strong> The main advantages include:<\/p>\n<ul data-start=\"881\" data-end=\"1261\">\n<li data-section-id=\"64b16q\" data-start=\"881\" data-end=\"935\">High reliability for outdoor substation applications<\/li>\n<li data-section-id=\"1s1moqy\" data-start=\"936\" data-end=\"983\">Excellent transformer oil cooling performance<\/li>\n<li data-section-id=\"rerucv\" data-start=\"984\" data-end=\"1021\">Low energy loss and high efficiency<\/li>\n<li data-section-id=\"18qp9k3\" data-start=\"1022\" data-end=\"1050\">Strong overload capability<\/li>\n<li data-section-id=\"189b2aa\" data-start=\"1051\" data-end=\"1086\">Superior short-circuit resistance<\/li>\n<li data-section-id=\"1wdzf4p\" data-start=\"1087\" data-end=\"1106\">Long service life<\/li>\n<li data-section-id=\"1sghyp\" data-start=\"1107\" data-end=\"1147\">Stable operation in harsh environments<\/li>\n<li data-section-id=\"1gci7ol\" data-start=\"1148\" data-end=\"1177\">Strong mechanical structure<\/li>\n<li data-section-id=\"dnl68g\" data-start=\"1178\" data-end=\"1210\">Flexible customization options<\/li>\n<li data-section-id=\"1edpil3\" data-start=\"1211\" data-end=\"1261\">Easy integration into power distribution systems<\/li>\n<\/ul>\n<hr data-start=\"1263\" data-end=\"1266\" \/>\n<h2 data-section-id=\"1iw5wqp\" data-start=\"1268\" data-end=\"1338\">Q3: What is the application of a 630kVA transformer in substations?<\/h2>\n<p data-start=\"1340\" data-end=\"1388\"><strong data-start=\"1340\" data-end=\"1346\">A:<\/strong> A 630kVA transformer is commonly used in:<\/p>\n<ul data-start=\"1390\" data-end=\"1559\">\n<li data-section-id=\"iknvhb\" data-start=\"1390\" data-end=\"1416\">Distribution substations<\/li>\n<li data-section-id=\"1eun78i\" data-start=\"1417\" data-end=\"1441\">Industrial substations<\/li>\n<li data-section-id=\"dpx96h\" data-start=\"1442\" data-end=\"1467\">Solar power substations<\/li>\n<li data-section-id=\"8vjcal\" data-start=\"1468\" data-end=\"1494\">Commercial power systems<\/li>\n<li data-section-id=\"1q5t4zr\" data-start=\"1495\" data-end=\"1527\">Rural electrification projects<\/li>\n<li data-section-id=\"guo6jh\" data-start=\"1528\" data-end=\"1559\">Infrastructure power networks<\/li>\n<\/ul>\n<p data-start=\"1561\" data-end=\"1679\">It provides voltage transformation and stable electricity distribution between medium-voltage and low-voltage systems.<\/p>\n<hr data-start=\"1681\" data-end=\"1684\" \/>\n<h2 data-section-id=\"11du9qd\" data-start=\"1686\" data-end=\"1741\">Q4: Can the 630kVA transformer convert 220V to 380V?<\/h2>\n<p data-start=\"1743\" data-end=\"1860\"><strong data-start=\"1743\" data-end=\"1749\">A:<\/strong> Yes. The transformer can be customized for 220V to 380V voltage conversion according to customer requirements.<\/p>\n<p data-start=\"1862\" data-end=\"1891\">Typical applications include:<\/p>\n<ul data-start=\"1893\" data-end=\"2045\">\n<li data-section-id=\"1q051e1\" data-start=\"1893\" data-end=\"1928\">Industrial equipment power supply<\/li>\n<li data-section-id=\"ybg3r3\" data-start=\"1929\" data-end=\"1963\">Low-voltage distribution systems<\/li>\n<li data-section-id=\"a4jaz5\" data-start=\"1964\" data-end=\"1986\">Commercial buildings<\/li>\n<li data-section-id=\"3afwns\" data-start=\"1987\" data-end=\"2015\">Agricultural power systems<\/li>\n<li data-section-id=\"gevsa2\" data-start=\"2016\" data-end=\"2045\">Remote area electrification<\/li>\n<\/ul>\n<p data-start=\"2047\" data-end=\"2148\">The exact voltage ratio can be adjusted according to local grid standards and project specifications.<\/p>\n<hr data-start=\"2150\" data-end=\"2153\" \/>\n<h2 data-section-id=\"yinr3s\" data-start=\"2155\" data-end=\"2241\">Q5: What are the available voltage ratings for the 630kVA Oil Immersed Transformer?<\/h2>\n<p data-start=\"2243\" data-end=\"2301\"><strong data-start=\"2243\" data-end=\"2249\">A:<\/strong> ZISHENG provides customized voltage configurations.<\/p>\n<p data-start=\"2303\" data-end=\"2339\">Common high voltage ratings include:<\/p>\n<ul data-start=\"2341\" data-end=\"2390\">\n<li data-section-id=\"1o2lj7\" data-start=\"2341\" data-end=\"2346\">6kV<\/li>\n<li data-section-id=\"1j29sus\" data-start=\"2347\" data-end=\"2353\">10kV<\/li>\n<li data-section-id=\"1j29tlh\" data-start=\"2354\" data-end=\"2360\">11kV<\/li>\n<li data-section-id=\"do3m4h\" data-start=\"2361\" data-end=\"2369\">13.8kV<\/li>\n<li data-section-id=\"1j29wy9\" data-start=\"2370\" data-end=\"2376\">15kV<\/li>\n<li data-section-id=\"1j2c27r\" data-start=\"2377\" data-end=\"2383\">20kV<\/li>\n<li data-section-id=\"1j2bger\" data-start=\"2384\" data-end=\"2390\">35kV<\/li>\n<\/ul>\n<p data-start=\"2392\" data-end=\"2427\">Common low voltage ratings include:<\/p>\n<ul data-start=\"2429\" data-end=\"2470\">\n<li data-section-id=\"1j2bzim\" data-start=\"2429\" data-end=\"2435\">220V<\/li>\n<li data-section-id=\"1j2b4f9\" data-start=\"2436\" data-end=\"2442\">380V<\/li>\n<li data-section-id=\"1j2dkqy\" data-start=\"2443\" data-end=\"2449\">400V<\/li>\n<li data-section-id=\"1j2dmzy\" data-start=\"2450\" data-end=\"2456\">415V<\/li>\n<li data-section-id=\"1j2de0y\" data-start=\"2457\" data-end=\"2463\">480V<\/li>\n<li data-section-id=\"1j2ezup\" data-start=\"2464\" data-end=\"2470\">690V<\/li>\n<\/ul>\n<p data-start=\"2472\" data-end=\"2552\">Customized voltage combinations are available according to project requirements.<\/p>\n<hr data-start=\"2554\" data-end=\"2557\" \/>\n<h2 data-section-id=\"10yv9ot\" data-start=\"2559\" data-end=\"2658\">Q6: What is the difference between a 630kVA Oil-Immersed Transformer and a Dry Type Transformer?<\/h2>\n<p data-start=\"2660\" data-end=\"2692\"><strong data-start=\"2660\" data-end=\"2666\">A:<\/strong> The main differences are:<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2694\" data-end=\"3221\">\n<thead data-start=\"2694\" data-end=\"2766\">\n<tr data-start=\"2694\" data-end=\"2766\">\n<th class=\"last:pe-10\" data-start=\"2694\" data-end=\"2701\" data-col-size=\"sm\">Item<\/th>\n<th class=\"last:pe-10\" data-start=\"2701\" data-end=\"2735\" data-col-size=\"md\">630kVA Oil-Immersed Transformer<\/th>\n<th class=\"last:pe-10\" data-start=\"2735\" data-end=\"2766\" data-col-size=\"md\">630kVA Dry Type Transformer<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2781\" data-end=\"3221\">\n<tr data-start=\"2781\" data-end=\"2839\">\n<td data-start=\"2781\" data-end=\"2798\" data-col-size=\"sm\">Cooling Method<\/td>\n<td data-start=\"2798\" data-end=\"2824\" data-col-size=\"md\">Transformer oil cooling<\/td>\n<td data-col-size=\"md\" data-start=\"2824\" data-end=\"2839\">Air cooling<\/td>\n<\/tr>\n<tr data-start=\"2840\" data-end=\"2898\">\n<td data-start=\"2840\" data-end=\"2860\" data-col-size=\"sm\">Insulation Medium<\/td>\n<td data-start=\"2860\" data-end=\"2878\" data-col-size=\"md\">Transformer oil<\/td>\n<td data-start=\"2878\" data-end=\"2898\" data-col-size=\"md\">Solid insulation<\/td>\n<\/tr>\n<tr data-start=\"2899\" data-end=\"2966\">\n<td data-start=\"2899\" data-end=\"2914\" data-col-size=\"sm\">Installation<\/td>\n<td data-start=\"2914\" data-end=\"2936\" data-col-size=\"md\">Outdoor substations<\/td>\n<td data-start=\"2936\" data-end=\"2966\" data-col-size=\"md\">Mainly indoor applications<\/td>\n<\/tr>\n<tr data-start=\"2967\" data-end=\"3006\">\n<td data-start=\"2967\" data-end=\"2986\" data-col-size=\"sm\">Heat Dissipation<\/td>\n<td data-start=\"2986\" data-end=\"2998\" data-col-size=\"md\">Excellent<\/td>\n<td data-start=\"2998\" data-end=\"3006\" data-col-size=\"md\">Good<\/td>\n<\/tr>\n<tr data-start=\"3007\" data-end=\"3050\">\n<td data-start=\"3007\" data-end=\"3029\" data-col-size=\"sm\">Overload Capability<\/td>\n<td data-col-size=\"md\" data-start=\"3029\" data-end=\"3038\">Strong<\/td>\n<td data-col-size=\"md\" data-start=\"3038\" data-end=\"3050\">Moderate<\/td>\n<\/tr>\n<tr data-start=\"3051\" data-end=\"3112\">\n<td data-start=\"3051\" data-end=\"3065\" data-col-size=\"sm\">Maintenance<\/td>\n<td data-start=\"3065\" data-end=\"3091\" data-col-size=\"md\">Requires oil inspection<\/td>\n<td data-start=\"3091\" data-end=\"3112\" data-col-size=\"md\">Lower maintenance<\/td>\n<\/tr>\n<tr data-start=\"3113\" data-end=\"3221\">\n<td data-start=\"3113\" data-end=\"3127\" data-col-size=\"sm\">Application<\/td>\n<td data-col-size=\"md\" data-start=\"3127\" data-end=\"3175\">Power grids, substations, industrial projects<\/td>\n<td data-col-size=\"md\" data-start=\"3175\" data-end=\"3221\">Buildings, data centers, indoor facilities<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"3223\" data-end=\"3356\">Oil-immersed transformers are preferred for outdoor substations and applications requiring high reliability and continuous operation.<\/p>\n<hr data-start=\"3358\" data-end=\"3361\" \/>\n<h2 data-section-id=\"9esmwz\" data-start=\"3363\" data-end=\"3426\">Q7: Is the 630kVA transformer available with copper winding?<\/h2>\n<p data-start=\"3428\" data-end=\"3493\"><strong data-start=\"3428\" data-end=\"3434\">A:<\/strong> Yes. ZISHENG provides copper and aluminum winding options.<\/p>\n<h3 data-section-id=\"1aaqstn\" data-start=\"3495\" data-end=\"3525\">Copper winding advantages:<\/h3>\n<ul data-start=\"3527\" data-end=\"3692\">\n<li data-section-id=\"gh17pq\" data-start=\"3527\" data-end=\"3548\">Higher conductivity<\/li>\n<li data-section-id=\"1vxdcz4\" data-start=\"3549\" data-end=\"3574\">Lower electrical losses<\/li>\n<li data-section-id=\"xug4ff\" data-start=\"3575\" data-end=\"3603\">Better thermal performance<\/li>\n<li data-section-id=\"5kwhp1\" data-start=\"3604\" data-end=\"3632\">Strong mechanical strength<\/li>\n<li data-section-id=\"1cx07q1\" data-start=\"3633\" data-end=\"3668\">Improved short-circuit resistance<\/li>\n<li data-section-id=\"xhwzv2\" data-start=\"3669\" data-end=\"3692\">Longer operating life<\/li>\n<\/ul>\n<p data-start=\"3694\" data-end=\"3791\">The winding material can be selected according to project requirements and budget considerations.<\/p>\n<hr data-start=\"3793\" data-end=\"3796\" \/>\n<h2 data-section-id=\"1n6tpxg\" data-start=\"3798\" data-end=\"3862\">Q8: What type of transformer oil is used in this transformer?<\/h2>\n<p data-start=\"3864\" data-end=\"3972\"><strong data-start=\"3864\" data-end=\"3870\">A:<\/strong> The 630kVA transformer uses high-quality transformer oil designed for power transformer applications.<\/p>\n<p data-start=\"3974\" data-end=\"3999\">Transformer oil provides:<\/p>\n<ul data-start=\"4001\" data-end=\"4141\">\n<li data-section-id=\"1fi0ceu\" data-start=\"4001\" data-end=\"4024\">Electrical insulation<\/li>\n<li data-section-id=\"svfpaj\" data-start=\"4025\" data-end=\"4051\">Heat transfer capability<\/li>\n<li data-section-id=\"17oxjr3\" data-start=\"4052\" data-end=\"4073\">Cooling performance<\/li>\n<li data-section-id=\"cb5pa1\" data-start=\"4074\" data-end=\"4109\">Protection of internal components<\/li>\n<li data-section-id=\"yarhdz\" data-start=\"4110\" data-end=\"4141\">Improved transformer lifespan<\/li>\n<\/ul>\n<p data-start=\"4143\" data-end=\"4218\">Special oil requirements can be customized according to customer standards.<\/p>\n<hr data-start=\"4220\" data-end=\"4223\" \/>\n<h2 data-section-id=\"lnyoed\" data-start=\"4225\" data-end=\"4296\">Q9: How does the oil cooling system improve transformer performance?<\/h2>\n<p data-start=\"4298\" data-end=\"4354\"><strong data-start=\"4298\" data-end=\"4304\">A:<\/strong> Transformer oil performs two important functions:<\/p>\n<h3 data-section-id=\"6jo7ht\" data-start=\"4356\" data-end=\"4377\">Cooling Function:<\/h3>\n<ul data-start=\"4378\" data-end=\"4497\">\n<li data-section-id=\"vuqftr\" data-start=\"4378\" data-end=\"4427\">Removes heat generated by the core and windings<\/li>\n<li data-section-id=\"17ucgle\" data-start=\"4428\" data-end=\"4466\">Maintains safe operating temperature<\/li>\n<li data-section-id=\"wu9e0p\" data-start=\"4467\" data-end=\"4497\">Improves overload capability<\/li>\n<\/ul>\n<h3 data-section-id=\"5ixci6\" data-start=\"4499\" data-end=\"4523\">Insulation Function:<\/h3>\n<ul data-start=\"4524\" data-end=\"4652\">\n<li data-section-id=\"183f0p3\" data-start=\"4524\" data-end=\"4584\">Provides electrical insulation between internal components<\/li>\n<li data-section-id=\"1ac0o56\" data-start=\"4585\" data-end=\"4619\">Enhances transformer reliability<\/li>\n<li data-section-id=\"1qlnupa\" data-start=\"4620\" data-end=\"4652\">Extends insulation system life<\/li>\n<\/ul>\n<hr data-start=\"4654\" data-end=\"4657\" \/>\n<h2 data-section-id=\"1d56kkb\" data-start=\"4659\" data-end=\"4716\">Q10: Can the 630kVA transformer be installed outdoors?<\/h2>\n<p data-start=\"4718\" data-end=\"4794\"><strong data-start=\"4718\" data-end=\"4724\">A:<\/strong> Yes. This transformer is specially designed for outdoor installation.<\/p>\n<p data-start=\"4796\" data-end=\"4827\">The outdoor structure provides:<\/p>\n<ul data-start=\"4829\" data-end=\"4941\">\n<li data-section-id=\"1dhs09f\" data-start=\"4829\" data-end=\"4849\">Weather resistance<\/li>\n<li data-section-id=\"1g9fqrp\" data-start=\"4850\" data-end=\"4871\">Moisture protection<\/li>\n<li data-section-id=\"8xa67x\" data-start=\"4872\" data-end=\"4889\">Dust protection<\/li>\n<li data-section-id=\"5kwhp1\" data-start=\"4890\" data-end=\"4918\">Strong mechanical strength<\/li>\n<li data-section-id=\"1u5w4v5\" data-start=\"4919\" data-end=\"4941\">Reliable oil sealing<\/li>\n<\/ul>\n<p data-start=\"4943\" data-end=\"4982\">It can operate in environments such as:<\/p>\n<ul data-start=\"4984\" data-end=\"5079\">\n<li data-section-id=\"1dwq9j1\" data-start=\"4984\" data-end=\"5002\">Tropical regions<\/li>\n<li data-section-id=\"11m5s8z\" data-start=\"5003\" data-end=\"5027\">High-temperature areas<\/li>\n<li data-section-id=\"1e6o464\" data-start=\"5028\" data-end=\"5053\">High-humidity locations<\/li>\n<li data-section-id=\"14p627d\" data-start=\"5054\" data-end=\"5079\">Industrial environments<\/li>\n<\/ul>\n<hr data-start=\"5081\" data-end=\"5084\" \/>\n<h2 data-section-id=\"1v1c7bi\" data-start=\"5086\" data-end=\"5158\">Q11: What maintenance does a 630kVA Oil-Immersed Transformer require?<\/h2>\n<p data-start=\"5160\" data-end=\"5196\"><strong data-start=\"5160\" data-end=\"5166\">A:<\/strong> Regular maintenance includes:<\/p>\n<ul data-start=\"5198\" data-end=\"5438\">\n<li data-section-id=\"1sbd0bt\" data-start=\"5198\" data-end=\"5230\">Checking transformer oil level<\/li>\n<li data-section-id=\"1wo1df8\" data-start=\"5231\" data-end=\"5255\">Inspecting oil leakage<\/li>\n<li data-section-id=\"ugnl4n\" data-start=\"5256\" data-end=\"5290\">Testing oil insulation condition<\/li>\n<li data-section-id=\"13luelt\" data-start=\"5291\" data-end=\"5310\">Checking bushings<\/li>\n<li data-section-id=\"uusit1\" data-start=\"5311\" data-end=\"5346\">Inspecting electrical connections<\/li>\n<li data-section-id=\"1vq5hv1\" data-start=\"5347\" data-end=\"5378\">Testing insulation resistance<\/li>\n<li data-section-id=\"bxw8ha\" data-start=\"5379\" data-end=\"5406\">Checking grounding system<\/li>\n<li data-section-id=\"1tl3mae\" data-start=\"5407\" data-end=\"5438\">Inspecting protection devices<\/li>\n<\/ul>\n<p data-start=\"5440\" data-end=\"5497\">Proper maintenance helps ensure long-term safe operation.<\/p>\n<hr data-start=\"5499\" data-end=\"5502\" \/>\n<h2 data-section-id=\"m25tqm\" data-start=\"5504\" data-end=\"5561\">Q12: What safety protection accessories are available?<\/h2>\n<p data-start=\"5563\" data-end=\"5633\"><strong data-start=\"5563\" data-end=\"5569\">A:<\/strong> ZISHENG can provide optional protection accessories, including:<\/p>\n<ul data-start=\"5635\" data-end=\"5789\">\n<li data-section-id=\"1axeqkv\" data-start=\"5635\" data-end=\"5662\">Oil temperature indicator<\/li>\n<li data-section-id=\"1gthgs5\" data-start=\"5663\" data-end=\"5684\">Oil level indicator<\/li>\n<li data-section-id=\"muahk4\" data-start=\"5685\" data-end=\"5709\">Pressure relief device<\/li>\n<li data-section-id=\"1lhq24s\" data-start=\"5710\" data-end=\"5730\">Lightning arrester<\/li>\n<li data-section-id=\"fewx34\" data-start=\"5731\" data-end=\"5749\">Conservator tank<\/li>\n<li data-section-id=\"1embb6u\" data-start=\"5750\" data-end=\"5766\">Buchholz relay<\/li>\n<li data-section-id=\"j6qyn7\" data-start=\"5767\" data-end=\"5789\">Protective enclosure<\/li>\n<\/ul>\n<p data-start=\"5791\" data-end=\"5863\">These accessories improve transformer monitoring and operational safety.<\/p>\n<hr data-start=\"5865\" data-end=\"5868\" \/>\n<h2 data-section-id=\"1nibgbl\" data-start=\"5870\" data-end=\"5933\">Q13: What standards does the 630kVA transformer comply with?<\/h2>\n<p data-start=\"5935\" data-end=\"5996\"><strong data-start=\"5935\" data-end=\"5941\">A:<\/strong> ZISHENG transformers can be manufactured according to:<\/p>\n<ul data-start=\"5998\" data-end=\"6097\">\n<li data-section-id=\"ocarov\" data-start=\"5998\" data-end=\"6013\">IEC standards<\/li>\n<li data-section-id=\"1qy8or9\" data-start=\"6014\" data-end=\"6030\">ANSI standards<\/li>\n<li data-section-id=\"195zzu9\" data-start=\"6031\" data-end=\"6066\">Customer technical specifications<\/li>\n<li data-section-id=\"lv7mlo\" data-start=\"6067\" data-end=\"6097\">Local electrical regulations<\/li>\n<\/ul>\n<p data-start=\"6099\" data-end=\"6209\">The transformer design can be adjusted according to the requirements of different countries and power systems.<\/p>\n<hr data-start=\"6211\" data-end=\"6214\" \/>\n<h2 data-section-id=\"e9qoiy\" data-start=\"6216\" data-end=\"6281\">Q14: Can the 630kVA transformer operate in harsh environments?<\/h2>\n<p data-start=\"6283\" data-end=\"6367\"><strong data-start=\"6283\" data-end=\"6289\">A:<\/strong> Yes. The transformer can be designed for challenging environments, including:<\/p>\n<ul data-start=\"6369\" data-end=\"6478\">\n<li data-section-id=\"1hab4ku\" data-start=\"6369\" data-end=\"6393\">High temperature areas<\/li>\n<li data-section-id=\"evncri\" data-start=\"6394\" data-end=\"6413\">Tropical climates<\/li>\n<li data-section-id=\"1jtog38\" data-start=\"6414\" data-end=\"6437\">High humidity regions<\/li>\n<li data-section-id=\"1c4rm7d\" data-start=\"6438\" data-end=\"6455\">Dusty locations<\/li>\n<li data-section-id=\"te6ds9\" data-start=\"6456\" data-end=\"6478\">Coastal environments<\/li>\n<\/ul>\n<p data-start=\"6480\" data-end=\"6562\">The durable tank structure and reliable insulation system ensure stable operation.<\/p>\n<hr data-start=\"6564\" data-end=\"6567\" \/>\n<h2 data-section-id=\"1j8tq8m\" data-start=\"6569\" data-end=\"6639\">Q15: What is the service life of a 630kVA Oil-Immersed Transformer?<\/h2>\n<p data-start=\"6641\" data-end=\"6776\"><strong data-start=\"6641\" data-end=\"6647\">A:<\/strong> A high-quality 630kVA Oil-Immersed Transformer can provide decades of reliable operation when properly installed and maintained.<\/p>\n<p data-start=\"6778\" data-end=\"6806\">The service life depends on:<\/p>\n<ul data-start=\"6808\" data-end=\"6933\">\n<li data-section-id=\"d28ylv\" data-start=\"6808\" data-end=\"6835\">Operating load conditions<\/li>\n<li data-section-id=\"1m3zy40\" data-start=\"6836\" data-end=\"6862\">Environmental conditions<\/li>\n<li data-section-id=\"18ylh7c\" data-start=\"6863\" data-end=\"6884\">Maintenance quality<\/li>\n<li data-section-id=\"12pi1hc\" data-start=\"6885\" data-end=\"6909\">Insulation performance<\/li>\n<li data-section-id=\"4bsz15\" data-start=\"6910\" data-end=\"6933\">Operating temperature<\/li>\n<\/ul>\n<p data-start=\"6935\" data-end=\"7038\">ZISHENG uses high-quality materials and strict manufacturing processes to ensure long-term performance.<\/p>\n<hr data-start=\"7040\" data-end=\"7043\" \/>\n<h2 data-section-id=\"c25w2i\" data-start=\"7045\" data-end=\"7135\">Q16: Why choose ZISHENG 630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer?<\/h2>\n<p data-start=\"7137\" data-end=\"7161\"><strong data-start=\"7137\" data-end=\"7143\">A:<\/strong> ZISHENG provides:<\/p>\n<ul data-start=\"7163\" data-end=\"7462\">\n<li data-section-id=\"m0o2jq\" data-start=\"7163\" data-end=\"7214\">Professional transformer manufacturing experience<\/li>\n<li data-section-id=\"oe63nq\" data-start=\"7215\" data-end=\"7242\">Multiple production lines<\/li>\n<li data-section-id=\"xqt2c2\" data-start=\"7243\" data-end=\"7271\">Stable production capacity<\/li>\n<li data-section-id=\"19mrpe8\" data-start=\"7272\" data-end=\"7307\">Advanced manufacturing technology<\/li>\n<li data-section-id=\"1wach9l\" data-start=\"7308\" data-end=\"7332\">Strict quality control<\/li>\n<li data-section-id=\"76tdlf\" data-start=\"7333\" data-end=\"7362\">Competitive factory pricing<\/li>\n<li data-section-id=\"1tua26y\" data-start=\"7363\" data-end=\"7397\">Customized engineering solutions<\/li>\n<li data-section-id=\"7qao7w\" data-start=\"7398\" data-end=\"7428\">Reliable delivery capability<\/li>\n<li data-section-id=\"78rhmw\" data-start=\"7429\" data-end=\"7462\">International export experience<\/li>\n<\/ul>\n<p data-start=\"7464\" data-end=\"7709\" data-is-last-node=\"\" data-is-only-node=\"\">ZISHENG <strong data-start=\"7472\" data-end=\"7538\">630kVA Three-Phase Oil-Immersed Outdoor Substation Transformer<\/strong> is a reliable power solution for utility companies, EPC contractors, renewable energy developers, industrial enterprises, and electrical equipment distributors worldwide.<\/p>","protected":false},"excerpt":{"rendered":"<p>This 630kVA three-phase oil-immersed transformer is designed for outdoor substations, providing reliable voltage conversion from 220V to 380V. With a robust oil-immersed cooling system, it ensures excellent heat dissipation, stable performance, and long service life. Ideal for industrial facilities, commercial power distribution, and utility applications, this step-up transformer delivers consistent efficiency even under heavy load conditions.<\/p>","protected":false},"featured_media":1649,"template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[],"product_cat":[72],"product_tag":[],"class_list":["post-1648","product","type-product","status-publish","has-post-thumbnail","product_cat-substation-transformer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product\/1648","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/media\/1649"}],"wp:attachment":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/media?parent=1648"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1648"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1648"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1648"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}