{"id":1653,"date":"2026-08-03T10:34:40","date_gmt":"2026-08-03T02:34:40","guid":{"rendered":"https:\/\/www.zishengelectric.com\/?post_type=product&#038;p=1653"},"modified":"2026-08-03T10:34:41","modified_gmt":"2026-08-03T02:34:41","slug":"25000kva-oil-immersed-copper-transformer-for-substation","status":"publish","type":"product","link":"https:\/\/www.zishengelectric.com\/ar\/product\/25000kva-oil-immersed-copper-transformer-for-substation","title":{"rendered":"25000kVA Oil-Immersed Copper Transformer For Substation"},"content":{"rendered":"<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"mejz8x\" data-start=\"89\" data-end=\"110\">1. Product Overview<\/h1>\n<p data-start=\"112\" data-end=\"365\">ZISHENG <strong data-start=\"120\" data-end=\"179\">25000kVA Oil-Immersed Copper Transformer for Substation<\/strong> is a high-capacity power transformer designed for large-scale power transmission and distribution systems, industrial substations, renewable energy projects, and utility power networks.<\/p>\n<p data-start=\"367\" data-end=\"580\">With a rated capacity of <strong data-start=\"392\" data-end=\"412\">25MVA (25000kVA)<\/strong>, this transformer is engineered to provide reliable voltage conversion, high power transmission capability, and stable operation for demanding electrical applications.<\/p>\n<p data-start=\"582\" data-end=\"844\">The transformer adopts <strong data-start=\"605\" data-end=\"637\">high-quality copper windings<\/strong> and <strong data-start=\"642\" data-end=\"695\">transformer oil insulation and cooling technology<\/strong>. The oil-immersed structure provides excellent heat dissipation, strong insulation performance, and reliable operation under continuous heavy loads.<\/p>\n<p data-start=\"846\" data-end=\"1022\">Manufactured with advanced transformer technology, premium electrical materials, and strict quality control procedures, ZISHENG 25000kVA Oil-Immersed Copper Transformer offers:<\/p>\n<ul data-start=\"1024\" data-end=\"1242\">\n<li data-section-id=\"l1j4dp\" data-start=\"1024\" data-end=\"1045\">High power capacity<\/li>\n<li data-section-id=\"3boosz\" data-start=\"1046\" data-end=\"1070\">High energy efficiency<\/li>\n<li data-section-id=\"c1yvr3\" data-start=\"1071\" data-end=\"1096\">Low transmission losses<\/li>\n<li data-section-id=\"1r43hr3\" data-start=\"1097\" data-end=\"1128\">Excellent thermal performance<\/li>\n<li data-section-id=\"6xt7nz\" data-start=\"1129\" data-end=\"1174\">Superior short-circuit withstand capability<\/li>\n<li data-section-id=\"4g6rze\" data-start=\"1175\" data-end=\"1222\">Reliable operation under demanding conditions<\/li>\n<li data-section-id=\"1wdzf4p\" data-start=\"1223\" data-end=\"1242\">Long service life<\/li>\n<\/ul>\n<p data-start=\"1244\" data-end=\"1268\">It is widely applied in:<\/p>\n<ul data-start=\"1270\" data-end=\"1454\">\n<li data-section-id=\"p1b3xh\" data-start=\"1270\" data-end=\"1291\">Utility substations<\/li>\n<li data-section-id=\"c4lcx0\" data-start=\"1292\" data-end=\"1317\">Industrial power plants<\/li>\n<li data-section-id=\"1vwk4n1\" data-start=\"1318\" data-end=\"1351\">Renewable energy power stations<\/li>\n<li data-section-id=\"46c11n\" data-start=\"1352\" data-end=\"1384\">Mining and metallurgy projects<\/li>\n<li data-section-id=\"191s644\" data-start=\"1385\" data-end=\"1416\">Large infrastructure projects<\/li>\n<li data-section-id=\"1yoabdu\" data-start=\"1417\" data-end=\"1454\">Regional power transmission systems<\/li>\n<\/ul>\n<hr data-start=\"1456\" data-end=\"1459\" \/>\n<h1 data-section-id=\"1c1ddwf\" data-start=\"1461\" data-end=\"1488\">2. Product Specifications<\/h1>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1490\" data-end=\"2224\">\n<thead data-start=\"1490\" data-end=\"1519\">\n<tr data-start=\"1490\" data-end=\"1519\">\n<th class=\"last:pe-10\" data-start=\"1490\" data-end=\"1502\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"1502\" data-end=\"1519\" data-col-size=\"md\">Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1530\" data-end=\"2224\">\n<tr data-start=\"1530\" data-end=\"1589\">\n<td data-start=\"1530\" data-end=\"1545\" data-col-size=\"sm\">Product Name<\/td>\n<td data-start=\"1545\" data-end=\"1589\" data-col-size=\"md\">25000kVA Oil-Immersed Copper Transformer<\/td>\n<\/tr>\n<tr data-start=\"1590\" data-end=\"1627\">\n<td data-start=\"1590\" data-end=\"1607\" data-col-size=\"sm\">Rated Capacity<\/td>\n<td data-start=\"1607\" data-end=\"1627\" data-col-size=\"md\">25000kVA \/ 25MVA<\/td>\n<\/tr>\n<tr data-start=\"1628\" data-end=\"1681\">\n<td data-start=\"1628\" data-end=\"1647\" data-col-size=\"sm\">Transformer Type<\/td>\n<td data-start=\"1647\" data-end=\"1681\" data-col-size=\"md\">Oil Immersed Power Transformer<\/td>\n<\/tr>\n<tr data-start=\"1682\" data-end=\"1705\">\n<td data-start=\"1682\" data-end=\"1690\" data-col-size=\"sm\">Phase<\/td>\n<td data-start=\"1690\" data-end=\"1705\" data-col-size=\"md\">Three Phase<\/td>\n<\/tr>\n<tr data-start=\"1706\" data-end=\"1755\">\n<td data-start=\"1706\" data-end=\"1720\" data-col-size=\"sm\">Application<\/td>\n<td data-start=\"1720\" data-end=\"1755\" data-col-size=\"md\">Substation \/ Power Transmission<\/td>\n<\/tr>\n<tr data-start=\"1756\" data-end=\"1797\">\n<td data-start=\"1756\" data-end=\"1775\" data-col-size=\"sm\">Winding Material<\/td>\n<td data-start=\"1775\" data-end=\"1797\" data-col-size=\"md\">High Purity Copper<\/td>\n<\/tr>\n<tr data-start=\"1798\" data-end=\"1825\">\n<td data-start=\"1798\" data-end=\"1810\" data-col-size=\"sm\">Frequency<\/td>\n<td data-start=\"1810\" data-end=\"1825\" data-col-size=\"md\">50Hz \/ 60Hz<\/td>\n<\/tr>\n<tr data-start=\"1826\" data-end=\"1860\">\n<td data-start=\"1826\" data-end=\"1846\" data-col-size=\"sm\">High Voltage Side<\/td>\n<td data-start=\"1846\" data-end=\"1860\" data-col-size=\"md\">Customized<\/td>\n<\/tr>\n<tr data-start=\"1861\" data-end=\"1894\">\n<td data-start=\"1861\" data-end=\"1880\" data-col-size=\"sm\">Low Voltage Side<\/td>\n<td data-start=\"1880\" data-end=\"1894\" data-col-size=\"md\">Customized<\/td>\n<\/tr>\n<tr data-start=\"1895\" data-end=\"1936\">\n<td data-start=\"1895\" data-end=\"1912\" data-col-size=\"sm\">Cooling Method<\/td>\n<td data-start=\"1912\" data-end=\"1936\" data-col-size=\"md\">ONAN \/ ONAF Optional<\/td>\n<\/tr>\n<tr data-start=\"1937\" data-end=\"1985\">\n<td data-start=\"1937\" data-end=\"1953\" data-col-size=\"sm\">Core Material<\/td>\n<td data-start=\"1953\" data-end=\"1985\" data-col-size=\"md\">Grain-Oriented Silicon Steel<\/td>\n<\/tr>\n<tr data-start=\"1986\" data-end=\"2025\">\n<td data-start=\"1986\" data-end=\"2006\" data-col-size=\"sm\">Insulation Medium<\/td>\n<td data-start=\"2006\" data-end=\"2025\" data-col-size=\"md\">Transformer Oil<\/td>\n<\/tr>\n<tr data-start=\"2026\" data-end=\"2066\">\n<td data-start=\"2026\" data-end=\"2046\" data-col-size=\"sm\">Installation Type<\/td>\n<td data-start=\"2046\" data-end=\"2066\" data-col-size=\"md\">Outdoor \/ Indoor<\/td>\n<\/tr>\n<tr data-start=\"2067\" data-end=\"2130\">\n<td data-start=\"2067\" data-end=\"2081\" data-col-size=\"sm\">Tap Changer<\/td>\n<td data-start=\"2081\" data-end=\"2130\" data-col-size=\"md\">Off-Circuit Tap Changer \/ On-Load Tap Changer<\/td>\n<\/tr>\n<tr data-start=\"2131\" data-end=\"2163\">\n<td data-start=\"2131\" data-end=\"2143\" data-col-size=\"sm\">Tank Type<\/td>\n<td data-start=\"2143\" data-end=\"2163\" data-col-size=\"md\">Conservator Type<\/td>\n<\/tr>\n<tr data-start=\"2164\" data-end=\"2224\">\n<td data-start=\"2164\" data-end=\"2186\" data-col-size=\"sm\">Standard Compliance<\/td>\n<td data-start=\"2186\" data-end=\"2224\" data-col-size=\"md\">IEC \/ ANSI \/ Customer Requirements<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"2226\" data-end=\"2229\" \/>\n<h1 data-section-id=\"15sho5z\" data-start=\"2231\" data-end=\"2257\">3. Main Structure Design<\/h1>\n<h2 data-section-id=\"144kq1c\" data-start=\"2259\" data-end=\"2300\">3.1 High-Efficiency Silicon Steel Core<\/h2>\n<p data-start=\"2302\" data-end=\"2386\">The 25000kVA transformer uses advanced grain-oriented silicon steel core technology.<\/p>\n<h3 data-section-id=\"q4c1cr\" data-start=\"2388\" data-end=\"2401\">Features:<\/h3>\n<ul data-start=\"2403\" data-end=\"2565\">\n<li data-section-id=\"991ezl\" data-start=\"2403\" data-end=\"2422\">Low magnetic loss<\/li>\n<li data-section-id=\"dtdthx\" data-start=\"2423\" data-end=\"2451\">High magnetic permeability<\/li>\n<li data-section-id=\"1uqoc6z\" data-start=\"2452\" data-end=\"2480\">Reduced excitation current<\/li>\n<li data-section-id=\"1mgzs9m\" data-start=\"2481\" data-end=\"2510\">Lower operating temperature<\/li>\n<li data-section-id=\"1kh8air\" data-start=\"2511\" data-end=\"2539\">Improved energy efficiency<\/li>\n<li data-section-id=\"1c13u4v\" data-start=\"2540\" data-end=\"2565\">Reduced operating noise<\/li>\n<\/ul>\n<p data-start=\"2567\" data-end=\"2700\">The optimized core design minimizes energy losses during continuous high-power operation and improves overall transformer efficiency.<\/p>\n<hr data-start=\"2702\" data-end=\"2705\" \/>\n<h1 data-section-id=\"zjo3zs\" data-start=\"2707\" data-end=\"2742\">3.2 Premium Copper Winding System<\/h1>\n<p data-start=\"2744\" data-end=\"2861\">The transformer adopts high-conductivity copper windings designed for large-capacity power transmission applications.<\/p>\n<h3 data-section-id=\"1d4avtd\" data-start=\"2863\" data-end=\"2897\">Advantages of Copper Windings:<\/h3>\n<ul data-start=\"2899\" data-end=\"3083\">\n<li data-section-id=\"1kf79r1\" data-start=\"2899\" data-end=\"2934\">Excellent electrical conductivity<\/li>\n<li data-section-id=\"1hgo0rv\" data-start=\"2935\" data-end=\"2958\">Lower resistance loss<\/li>\n<li data-section-id=\"1rdyjda\" data-start=\"2959\" data-end=\"2989\">Superior thermal performance<\/li>\n<li data-section-id=\"5kwhp1\" data-start=\"2990\" data-end=\"3018\">Strong mechanical strength<\/li>\n<li data-section-id=\"rsmcwz\" data-start=\"3019\" data-end=\"3055\">Excellent short-circuit resistance<\/li>\n<li data-section-id=\"1x4uq28\" data-start=\"3056\" data-end=\"3083\">Long operational lifespan<\/li>\n<\/ul>\n<p data-start=\"3085\" data-end=\"3205\">The copper winding structure improves transformer efficiency and ensures stable performance under heavy load conditions.<\/p>\n<hr data-start=\"3207\" data-end=\"3210\" \/>\n<h1 data-section-id=\"1uxdost\" data-start=\"3212\" data-end=\"3260\">3.3 Advanced Oil Cooling and Insulation System<\/h1>\n<p data-start=\"3262\" data-end=\"3350\">The transformer uses high-quality transformer oil as both cooling and insulation medium.<\/p>\n<h3 data-section-id=\"almls6\" data-start=\"3352\" data-end=\"3371\">Main Functions:<\/h3>\n<ul data-start=\"3373\" data-end=\"3562\">\n<li data-section-id=\"1n21uzv\" data-start=\"3373\" data-end=\"3420\">Transfers heat generated by core and windings<\/li>\n<li data-section-id=\"1rwqrbq\" data-start=\"3421\" data-end=\"3453\">Provides electrical insulation<\/li>\n<li data-section-id=\"wu9e0p\" data-start=\"3454\" data-end=\"3484\">Improves overload capability<\/li>\n<li data-section-id=\"1d8noce\" data-start=\"3485\" data-end=\"3525\">Maintains stable operating temperature<\/li>\n<li data-section-id=\"1swe0yq\" data-start=\"3526\" data-end=\"3562\">Extends insulation system lifespan<\/li>\n<\/ul>\n<p data-start=\"3564\" data-end=\"3631\">For higher capacity applications, optional cooling methods include:<\/p>\n<ul data-start=\"3633\" data-end=\"3697\">\n<li data-section-id=\"tovvp3\" data-start=\"3633\" data-end=\"3665\">ONAN (Oil Natural Air Natural)<\/li>\n<li data-section-id=\"ahzhbr\" data-start=\"3666\" data-end=\"3697\">ONAF (Oil Natural Air Forced)<\/li>\n<\/ul>\n<p data-start=\"3699\" data-end=\"3785\">These cooling systems ensure reliable operation under continuous high-load conditions.<\/p>\n<hr data-start=\"3787\" data-end=\"3790\" \/>\n<h1 data-section-id=\"1qrfzer\" data-start=\"3792\" data-end=\"3835\">3.4 Heavy-Duty Transformer Tank Structure<\/h1>\n<p data-start=\"3837\" data-end=\"3913\">The transformer tank is designed for large-capacity substation applications.<\/p>\n<h3 data-section-id=\"q4c1cr\" data-start=\"3915\" data-end=\"3928\">Features:<\/h3>\n<ul data-start=\"3930\" data-end=\"4084\">\n<li data-section-id=\"1c0tsp4\" data-start=\"3930\" data-end=\"3956\">High mechanical strength<\/li>\n<li data-section-id=\"ytryvj\" data-start=\"3957\" data-end=\"3988\">Excellent sealing performance<\/li>\n<li data-section-id=\"10ltp7b\" data-start=\"3989\" data-end=\"4020\">Strong oil leakage prevention<\/li>\n<li data-section-id=\"3zl5sb\" data-start=\"4021\" data-end=\"4049\">Outdoor weather resistance<\/li>\n<li data-section-id=\"10id19o\" data-start=\"4050\" data-end=\"4084\">Long-term structural reliability<\/li>\n<\/ul>\n<p data-start=\"4086\" data-end=\"4130\">The robust tank design enables operation in:<\/p>\n<ul data-start=\"4132\" data-end=\"4226\">\n<li data-section-id=\"16tad4c\" data-start=\"4132\" data-end=\"4158\">High-temperature regions<\/li>\n<li data-section-id=\"evncri\" data-start=\"4159\" data-end=\"4178\">Tropical climates<\/li>\n<li data-section-id=\"14p627d\" data-start=\"4179\" data-end=\"4204\">Industrial environments<\/li>\n<li data-section-id=\"ll2ev1\" data-start=\"4205\" data-end=\"4226\">Outdoor substations<\/li>\n<\/ul>\n<hr data-start=\"4228\" data-end=\"4231\" \/>\n<h1 data-section-id=\"1lhqkqr\" data-start=\"4233\" data-end=\"4273\">3.5 Advanced Voltage Regulation System<\/h1>\n<p data-start=\"4275\" data-end=\"4312\">The transformer can be equipped with:<\/p>\n<ul data-start=\"4314\" data-end=\"4368\">\n<li data-section-id=\"19mk3s8\" data-start=\"4314\" data-end=\"4339\">Off-circuit tap changer<\/li>\n<li data-section-id=\"wji7s6\" data-start=\"4340\" data-end=\"4368\">On-load tap changer (OLTC)<\/li>\n<\/ul>\n<h3 data-section-id=\"1iaul7c\" data-start=\"4370\" data-end=\"4383\">Benefits:<\/h3>\n<ul data-start=\"4385\" data-end=\"4496\">\n<li data-section-id=\"1xn97q0\" data-start=\"4385\" data-end=\"4408\">Stable output voltage<\/li>\n<li data-section-id=\"ku0q9w\" data-start=\"4409\" data-end=\"4433\">Improved power quality<\/li>\n<li data-section-id=\"6gdgj4\" data-start=\"4434\" data-end=\"4459\">Flexible grid operation<\/li>\n<li data-section-id=\"zegu67\" data-start=\"4460\" data-end=\"4496\">Adaptation to voltage fluctuations<\/li>\n<\/ul>\n<hr data-start=\"4498\" data-end=\"4501\" \/>\n<h1 data-section-id=\"9j231r\" data-start=\"4503\" data-end=\"4526\">4. Product Advantages<\/h1>\n<h2 data-section-id=\"1xxwdw2\" data-start=\"4528\" data-end=\"4565\">High Power Transmission Capability<\/h2>\n<p data-start=\"4567\" data-end=\"4679\">The 25000kVA transformer is designed for large-scale power systems requiring high capacity and stable operation.<\/p>\n<p data-start=\"4681\" data-end=\"4694\">Suitable for:<\/p>\n<ul data-start=\"4696\" data-end=\"4796\">\n<li data-section-id=\"18vr4g5\" data-start=\"4696\" data-end=\"4721\">Power generation plants<\/li>\n<li data-section-id=\"14p6om5\" data-start=\"4722\" data-end=\"4740\">Grid substations<\/li>\n<li data-section-id=\"1sba3a5\" data-start=\"4741\" data-end=\"4768\">Industrial power networks<\/li>\n<li data-section-id=\"14u8sxu\" data-start=\"4769\" data-end=\"4796\">Renewable energy stations<\/li>\n<\/ul>\n<hr data-start=\"4798\" data-end=\"4801\" \/>\n<h2 data-section-id=\"lq5ec4\" data-start=\"4803\" data-end=\"4833\">Excellent Energy Efficiency<\/h2>\n<p data-start=\"4835\" data-end=\"4923\">The transformer adopts advanced low-loss materials and optimized electromagnetic design.<\/p>\n<p data-start=\"4925\" data-end=\"4934\">Benefits:<\/p>\n<ul data-start=\"4936\" data-end=\"5032\">\n<li data-section-id=\"1q5cah1\" data-start=\"4936\" data-end=\"4958\">Reduced no-load loss<\/li>\n<li data-section-id=\"1aw35ah\" data-start=\"4959\" data-end=\"4978\">Reduced load loss<\/li>\n<li data-section-id=\"df4632\" data-start=\"4979\" data-end=\"5002\">Lower operating costs<\/li>\n<li data-section-id=\"1gwqwny\" data-start=\"5003\" data-end=\"5032\">Improved energy utilization<\/li>\n<\/ul>\n<hr data-start=\"5034\" data-end=\"5037\" \/>\n<h2 data-section-id=\"1aujk67\" data-start=\"5039\" data-end=\"5075\">Superior Short-Circuit Resistance<\/h2>\n<p data-start=\"5077\" data-end=\"5197\">The reinforced copper winding structure and mechanical design provide excellent resistance against short-circuit forces.<\/p>\n<p data-start=\"5199\" data-end=\"5210\">Advantages:<\/p>\n<ul data-start=\"5212\" data-end=\"5304\">\n<li data-section-id=\"1jbr70v\" data-start=\"5212\" data-end=\"5236\">Improved system safety<\/li>\n<li data-section-id=\"152s51h\" data-start=\"5237\" data-end=\"5269\">Reduced equipment failure risk<\/li>\n<li data-section-id=\"3owzv2\" data-start=\"5270\" data-end=\"5304\">Enhanced operational reliability<\/li>\n<\/ul>\n<hr data-start=\"5306\" data-end=\"5309\" \/>\n<h2 data-section-id=\"kwluum\" data-start=\"5311\" data-end=\"5340\">Strong Overload Capability<\/h2>\n<p data-start=\"5342\" data-end=\"5466\">The efficient cooling system and robust internal structure allow the transformer to withstand temporary overload conditions.<\/p>\n<p data-start=\"5468\" data-end=\"5481\">Suitable for:<\/p>\n<ul data-start=\"5483\" data-end=\"5561\">\n<li data-section-id=\"t22ijp\" data-start=\"5483\" data-end=\"5506\">Industrial peak loads<\/li>\n<li data-section-id=\"1skx3jo\" data-start=\"5507\" data-end=\"5529\">Grid load variations<\/li>\n<li data-section-id=\"9pmf14\" data-start=\"5530\" data-end=\"5561\">Renewable energy fluctuations<\/li>\n<\/ul>\n<hr data-start=\"5563\" data-end=\"5566\" \/>\n<h2 data-section-id=\"9hrom9\" data-start=\"5568\" data-end=\"5599\">Reliable Long-Term Operation<\/h2>\n<p data-start=\"5601\" data-end=\"5620\">The combination of:<\/p>\n<ul data-start=\"5622\" data-end=\"5744\">\n<li data-section-id=\"17mcrqy\" data-start=\"5622\" data-end=\"5652\">High-quality copper windings<\/li>\n<li data-section-id=\"w3gnp7\" data-start=\"5653\" data-end=\"5683\">Premium insulation materials<\/li>\n<li data-section-id=\"19mrpe8\" data-start=\"5684\" data-end=\"5719\">Advanced manufacturing technology<\/li>\n<li data-section-id=\"1wach9l\" data-start=\"5720\" data-end=\"5744\">Strict quality control<\/li>\n<\/ul>\n<p data-start=\"5746\" data-end=\"5795\">ensures long service life and stable performance.<\/p>\n<hr data-start=\"5797\" data-end=\"5800\" \/>\n<h1 data-section-id=\"194sy77\" data-start=\"5802\" data-end=\"5824\">5. Application Areas<\/h1>\n<h2 data-section-id=\"kx0nhr\" data-start=\"5826\" data-end=\"5851\">Power Grid Substations<\/h2>\n<ul data-start=\"5853\" data-end=\"5941\">\n<li data-section-id=\"4amxz8\" data-start=\"5853\" data-end=\"5879\">High-voltage substations<\/li>\n<li data-section-id=\"1iz5jmb\" data-start=\"5880\" data-end=\"5903\">Transmission networks<\/li>\n<li data-section-id=\"1nl75ji\" data-start=\"5904\" data-end=\"5941\">Regional power distribution systems<\/li>\n<\/ul>\n<hr data-start=\"5943\" data-end=\"5946\" \/>\n<h2 data-section-id=\"k2nesr\" data-start=\"5948\" data-end=\"5975\">Industrial Power Systems<\/h2>\n<ul data-start=\"5977\" data-end=\"6081\">\n<li data-section-id=\"13wjk53\" data-start=\"5977\" data-end=\"5991\">Steel plants<\/li>\n<li data-section-id=\"w4ylc4\" data-start=\"5992\" data-end=\"6011\">Mining operations<\/li>\n<li data-section-id=\"1nbop3s\" data-start=\"6012\" data-end=\"6029\">Chemical plants<\/li>\n<li data-section-id=\"1i0u86j\" data-start=\"6030\" data-end=\"6056\">Manufacturing facilities<\/li>\n<li data-section-id=\"vb507d\" data-start=\"6057\" data-end=\"6081\">Large industrial parks<\/li>\n<\/ul>\n<hr data-start=\"6083\" data-end=\"6086\" \/>\n<h2 data-section-id=\"lg5s3k\" data-start=\"6088\" data-end=\"6116\">Renewable Energy Projects<\/h2>\n<ul data-start=\"6118\" data-end=\"6191\">\n<li data-section-id=\"1m5coyw\" data-start=\"6118\" data-end=\"6150\">Large-scale solar power plants<\/li>\n<li data-section-id=\"elqwfr\" data-start=\"6151\" data-end=\"6163\">Wind farms<\/li>\n<li data-section-id=\"1enf1xs\" data-start=\"6164\" data-end=\"6191\">Energy storage facilities<\/li>\n<\/ul>\n<hr data-start=\"6193\" data-end=\"6196\" \/>\n<h2 data-section-id=\"1y00iw4\" data-start=\"6198\" data-end=\"6224\">Infrastructure Projects<\/h2>\n<ul data-start=\"6226\" data-end=\"6278\">\n<li data-section-id=\"aqefvm\" data-start=\"6226\" data-end=\"6236\">Railways<\/li>\n<li data-section-id=\"1g8mpg8\" data-start=\"6237\" data-end=\"6247\">Airports<\/li>\n<li data-section-id=\"1753t6q\" data-start=\"6248\" data-end=\"6255\">Ports<\/li>\n<li data-section-id=\"k8f68g\" data-start=\"6256\" data-end=\"6278\">Urban power networks<\/li>\n<\/ul>\n<hr data-start=\"6280\" data-end=\"6283\" \/>\n<h1 data-section-id=\"cpbqi2\" data-start=\"6285\" data-end=\"6308\">6. Technical Features<\/h1>\n<h2 data-section-id=\"5rkj6x\" data-start=\"6310\" data-end=\"6336\">High Reliability Design<\/h2>\n<p data-start=\"6338\" data-end=\"6377\">Designed for continuous operation with:<\/p>\n<ul data-start=\"6379\" data-end=\"6502\">\n<li data-section-id=\"12b44j2\" data-start=\"6379\" data-end=\"6405\">Strong insulation system<\/li>\n<li data-section-id=\"f2ydcv\" data-start=\"6406\" data-end=\"6439\">Reinforced mechanical structure<\/li>\n<li data-section-id=\"tg2cws\" data-start=\"6440\" data-end=\"6465\">Advanced cooling system<\/li>\n<li data-section-id=\"19mlfhw\" data-start=\"6466\" data-end=\"6502\">High-quality electrical components<\/li>\n<\/ul>\n<hr data-start=\"6504\" data-end=\"6507\" \/>\n<h2 data-section-id=\"1xs54a9\" data-start=\"6509\" data-end=\"6543\">Outdoor Installation Capability<\/h2>\n<p data-start=\"6545\" data-end=\"6602\">The transformer is suitable for outdoor substations with:<\/p>\n<ul data-start=\"6604\" data-end=\"6722\">\n<li data-section-id=\"6nir7i\" data-start=\"6604\" data-end=\"6630\">Weather-resistant design<\/li>\n<li data-section-id=\"ouyl0r\" data-start=\"6631\" data-end=\"6657\">Anti-corrosion treatment<\/li>\n<li data-section-id=\"yuhewu\" data-start=\"6658\" data-end=\"6686\">Reliable sealing structure<\/li>\n<li data-section-id=\"1d06lnl\" data-start=\"6687\" data-end=\"6722\">Strong environmental adaptability<\/li>\n<\/ul>\n<hr data-start=\"6724\" data-end=\"6727\" \/>\n<h2 data-section-id=\"1ht8mmr\" data-start=\"6729\" data-end=\"6759\">Low Maintenance Requirement<\/h2>\n<p data-start=\"6761\" data-end=\"6794\">Recommended maintenance includes:<\/p>\n<ul data-start=\"6796\" data-end=\"6955\">\n<li data-section-id=\"jbjaxb\" data-start=\"6796\" data-end=\"6821\">Transformer oil testing<\/li>\n<li data-section-id=\"dsjpm2\" data-start=\"6822\" data-end=\"6844\">Oil level inspection<\/li>\n<li data-section-id=\"1dtfkmy\" data-start=\"6845\" data-end=\"6865\">Bushing inspection<\/li>\n<li data-section-id=\"1wqu9k4\" data-start=\"6866\" data-end=\"6891\">Cooling system checking<\/li>\n<li data-section-id=\"15f5r06\" data-start=\"6892\" data-end=\"6924\">Insulation performance testing<\/li>\n<li data-section-id=\"4vkn9p\" data-start=\"6925\" data-end=\"6955\">Protection device inspection<\/li>\n<\/ul>\n<p data-start=\"6957\" data-end=\"7027\">Regular maintenance improves transformer reliability and service life.<\/p>\n<hr data-start=\"7029\" data-end=\"7032\" \/>\n<h2 data-section-id=\"1bdguvx\" data-start=\"7034\" data-end=\"7067\">Flexible Customization Options<\/h2>\n<p data-start=\"7069\" data-end=\"7141\">ZISHENG provides customized solutions according to project requirements.<\/p>\n<p data-start=\"7143\" data-end=\"7161\">Available options:<\/p>\n<ul data-start=\"7163\" data-end=\"7353\">\n<li data-section-id=\"1ig7nqj\" data-start=\"7163\" data-end=\"7178\">Voltage ratio<\/li>\n<li data-section-id=\"1hrce0x\" data-start=\"7179\" data-end=\"7202\">Frequency (50Hz\/60Hz)<\/li>\n<li data-section-id=\"1fmx42i\" data-start=\"7203\" data-end=\"7233\">Copper winding specification<\/li>\n<li data-section-id=\"1y4t33i\" data-start=\"7234\" data-end=\"7248\">Vector group<\/li>\n<li data-section-id=\"qgmjgf\" data-start=\"7249\" data-end=\"7266\">Impedance value<\/li>\n<li data-section-id=\"1gstmu0\" data-start=\"7267\" data-end=\"7283\">Cooling method<\/li>\n<li data-section-id=\"18xd3kx\" data-start=\"7284\" data-end=\"7302\">Tap changer type<\/li>\n<li data-section-id=\"1sby1hq\" data-start=\"7303\" data-end=\"7322\">Protection system<\/li>\n<li data-section-id=\"1ykgsgz\" data-start=\"7323\" data-end=\"7353\">Special environmental design<\/li>\n<\/ul>\n<p data-start=\"7355\" data-end=\"7376\">Optional accessories:<\/p>\n<ul data-start=\"7378\" data-end=\"7525\">\n<li data-section-id=\"1axeqkv\" data-start=\"7378\" data-end=\"7405\">Oil temperature indicator<\/li>\n<li data-section-id=\"1gthgs5\" data-start=\"7406\" data-end=\"7427\">Oil level indicator<\/li>\n<li data-section-id=\"muahk4\" data-start=\"7428\" data-end=\"7452\">Pressure relief device<\/li>\n<li data-section-id=\"1embb6u\" data-start=\"7453\" data-end=\"7469\">Buchholz relay<\/li>\n<li data-section-id=\"1lhq24s\" data-start=\"7470\" data-end=\"7490\">Lightning arrester<\/li>\n<li data-section-id=\"1umv7j1\" data-start=\"7491\" data-end=\"7505\">Cooling fans<\/li>\n<li data-section-id=\"lxnyox\" data-start=\"7506\" data-end=\"7525\">Monitoring system<\/li>\n<\/ul>\n<hr data-start=\"7527\" data-end=\"7530\" \/>\n<h1 data-section-id=\"1g2ihud\" data-start=\"7532\" data-end=\"7578\">7. Manufacturing Process and Quality Control<\/h1>\n<p data-start=\"7580\" data-end=\"7668\">ZISHENG applies strict quality management throughout the complete manufacturing process.<\/p>\n<h2 data-section-id=\"1hamono\" data-start=\"7670\" data-end=\"7696\">Raw Material Inspection<\/h2>\n<p data-start=\"7698\" data-end=\"7708\">Including:<\/p>\n<ul data-start=\"7710\" data-end=\"7838\">\n<li data-section-id=\"usgcr8\" data-start=\"7710\" data-end=\"7739\">Copper conductor inspection<\/li>\n<li data-section-id=\"sel3jv\" data-start=\"7740\" data-end=\"7771\">Silicon steel core inspection<\/li>\n<li data-section-id=\"z21j9p\" data-start=\"7772\" data-end=\"7804\">Insulation material inspection<\/li>\n<li data-section-id=\"3i88rm\" data-start=\"7805\" data-end=\"7838\">Transformer oil quality testing<\/li>\n<\/ul>\n<hr data-start=\"7840\" data-end=\"7843\" \/>\n<h2 data-section-id=\"1295219\" data-start=\"7845\" data-end=\"7866\">Production Process<\/h2>\n<p data-start=\"7868\" data-end=\"7878\">Including:<\/p>\n<ul data-start=\"7880\" data-end=\"8034\">\n<li data-section-id=\"7kptlf\" data-start=\"7880\" data-end=\"7900\">Core manufacturing<\/li>\n<li data-section-id=\"15xf6ro\" data-start=\"7901\" data-end=\"7928\">Copper winding production<\/li>\n<li data-section-id=\"1lwytie\" data-start=\"7929\" data-end=\"7950\">Insulation assembly<\/li>\n<li data-section-id=\"1ofzewt\" data-start=\"7951\" data-end=\"7978\">Transformer body assembly<\/li>\n<li data-section-id=\"1f8yjzs\" data-start=\"7979\" data-end=\"7997\">Tank fabrication<\/li>\n<li data-section-id=\"1kfel32\" data-start=\"7998\" data-end=\"8013\">Vacuum drying<\/li>\n<li data-section-id=\"14q153o\" data-start=\"8014\" data-end=\"8034\">Vacuum oil filling<\/li>\n<\/ul>\n<hr data-start=\"8036\" data-end=\"8039\" \/>\n<h2 data-section-id=\"1ynqff\" data-start=\"8041\" data-end=\"8065\">Final Factory Testing<\/h2>\n<p data-start=\"8067\" data-end=\"8125\">Each 25000kVA transformer undergoes comprehensive testing:<\/p>\n<ul data-start=\"8127\" data-end=\"8380\">\n<li data-section-id=\"13jcszt\" data-start=\"8127\" data-end=\"8152\">Winding resistance test<\/li>\n<li data-section-id=\"19g9fot\" data-start=\"8153\" data-end=\"8181\">Insulation resistance test<\/li>\n<li data-section-id=\"1c0uslg\" data-start=\"8182\" data-end=\"8206\">Transformer ratio test<\/li>\n<li data-section-id=\"1lot3kn\" data-start=\"8207\" data-end=\"8226\">No-load loss test<\/li>\n<li data-section-id=\"9opfkr\" data-start=\"8227\" data-end=\"8243\">Load loss test<\/li>\n<li data-section-id=\"i83fx1\" data-start=\"8244\" data-end=\"8270\">Dielectric strength test<\/li>\n<li data-section-id=\"70rzy7\" data-start=\"8271\" data-end=\"8294\">Temperature rise test<\/li>\n<li data-section-id=\"f88wac\" data-start=\"8295\" data-end=\"8313\">Oil leakage test<\/li>\n<li data-section-id=\"79kycz\" data-start=\"8314\" data-end=\"8352\">Short-circuit withstand verification<\/li>\n<li data-section-id=\"14kcd14\" data-start=\"8353\" data-end=\"8380\">Protection system testing<\/li>\n<\/ul>\n<p data-start=\"8382\" data-end=\"8436\">Only qualified transformers are approved for delivery.<\/p>\n<hr data-start=\"8438\" data-end=\"8441\" \/>\n<h1 data-section-id=\"7qlqgf\" data-start=\"8443\" data-end=\"8507\">8. Why Choose ZISHENG 25000kVA Oil-Immersed Copper Transformer<\/h1>\n<ul data-start=\"8509\" data-end=\"8830\">\n<li data-section-id=\"15fefe7\" data-start=\"8509\" data-end=\"8548\">Professional transformer manufacturer<\/li>\n<li data-section-id=\"19mrpe8\" data-start=\"8549\" data-end=\"8584\">Advanced manufacturing technology<\/li>\n<li data-section-id=\"3vewuv\" data-start=\"8585\" data-end=\"8634\">High-capacity transformer production capability<\/li>\n<li data-section-id=\"c9xrac\" data-start=\"8635\" data-end=\"8669\">Premium copper winding materials<\/li>\n<li data-section-id=\"drxkcs\" data-start=\"8670\" data-end=\"8701\">Strict quality control system<\/li>\n<li data-section-id=\"1tua26y\" data-start=\"8702\" data-end=\"8736\">Customized engineering solutions<\/li>\n<li data-section-id=\"xqt2c2\" data-start=\"8737\" data-end=\"8765\">Stable production capacity<\/li>\n<li data-section-id=\"7qao7w\" data-start=\"8766\" data-end=\"8796\">Reliable delivery capability<\/li>\n<li data-section-id=\"78rhmw\" data-start=\"8797\" data-end=\"8830\">International export experience<\/li>\n<\/ul>\n<p data-start=\"8832\" data-end=\"9111\" data-is-last-node=\"\" data-is-only-node=\"\">ZISHENG <strong data-start=\"8840\" data-end=\"8899\">25000kVA Oil-Immersed Copper Transformer for Substation<\/strong> provides a reliable, efficient, and high-performance power solution for utility companies, EPC contractors, renewable energy developers, industrial enterprises, and large-scale infrastructure projects worldwide.<\/p>\n<h1 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1g93s0z\" data-start=\"0\" data-end=\"59\">25000kVA Oil-Immersed Copper Transformer for Substation<\/h1>\n<h2 data-section-id=\"1ehkqyg\" data-start=\"60\" data-end=\"74\">Product Q&amp;A<\/h2>\n<hr data-start=\"76\" data-end=\"79\" \/>\n<h2 data-section-id=\"cpx3w1\" data-start=\"81\" data-end=\"139\">Q1: What is a 25000kVA Oil-Immersed Copper Transformer?<\/h2>\n<p data-start=\"141\" data-end=\"347\"><strong data-start=\"141\" data-end=\"147\">A:<\/strong> A 25000kVA Oil-Immersed Copper Transformer is a high-capacity power transformer designed for large-scale substations, power transmission systems, industrial facilities, and renewable energy projects.<\/p>\n<p data-start=\"349\" data-end=\"593\">With a rated capacity of <strong data-start=\"374\" data-end=\"383\">25MVA<\/strong>, the transformer uses high-quality copper windings and transformer oil as the cooling and insulation medium to provide efficient voltage conversion, stable power transmission, and reliable long-term operation.<\/p>\n<p data-start=\"595\" data-end=\"744\">It is mainly used in medium and high-voltage power networks where high capacity, high reliability, and excellent electrical performance are required.<\/p>\n<hr data-start=\"746\" data-end=\"749\" \/>\n<h2 data-section-id=\"l9y7fa\" data-start=\"751\" data-end=\"820\">Q2: What are the main advantages of a 25000kVA Copper Transformer?<\/h2>\n<p data-start=\"822\" data-end=\"857\"><strong data-start=\"822\" data-end=\"828\">A:<\/strong> The main advantages include:<\/p>\n<ul data-start=\"859\" data-end=\"1188\">\n<li data-section-id=\"fcxdln\" data-start=\"859\" data-end=\"893\">High power transmission capacity<\/li>\n<li data-section-id=\"e862y7\" data-start=\"894\" data-end=\"931\">High efficiency and low energy loss<\/li>\n<li data-section-id=\"4e4d0k\" data-start=\"932\" data-end=\"968\">Premium copper winding performance<\/li>\n<li data-section-id=\"1fnuny5\" data-start=\"969\" data-end=\"997\">Excellent heat dissipation<\/li>\n<li data-section-id=\"18qp9k3\" data-start=\"998\" data-end=\"1026\">Strong overload capability<\/li>\n<li data-section-id=\"189b2aa\" data-start=\"1027\" data-end=\"1062\">Superior short-circuit resistance<\/li>\n<li data-section-id=\"1s3mqhk\" data-start=\"1063\" data-end=\"1096\">Reliable insulation performance<\/li>\n<li data-section-id=\"1wdzf4p\" data-start=\"1097\" data-end=\"1116\">Long service life<\/li>\n<li data-section-id=\"m2gv66\" data-start=\"1117\" data-end=\"1153\">Stable operation under heavy loads<\/li>\n<li data-section-id=\"11bsb87\" data-start=\"1154\" data-end=\"1188\">Suitable for outdoor substations<\/li>\n<\/ul>\n<hr data-start=\"1190\" data-end=\"1193\" \/>\n<h2 data-section-id=\"q1ur2o\" data-start=\"1195\" data-end=\"1261\">Q3: Where is a 25000kVA Oil-Immersed Transformer commonly used?<\/h2>\n<p data-start=\"1263\" data-end=\"1304\"><strong data-start=\"1263\" data-end=\"1269\">A:<\/strong> The transformer is widely used in:<\/p>\n<ul data-start=\"1306\" data-end=\"1576\">\n<li data-section-id=\"bhsh2y\" data-start=\"1306\" data-end=\"1333\">Utility power substations<\/li>\n<li data-section-id=\"18o9vtu\" data-start=\"1334\" data-end=\"1374\">Transmission and distribution networks<\/li>\n<li data-section-id=\"18vr4g5\" data-start=\"1375\" data-end=\"1400\">Power generation plants<\/li>\n<li data-section-id=\"1dq72m3\" data-start=\"1401\" data-end=\"1436\">Solar photovoltaic power stations<\/li>\n<li data-section-id=\"gvaqn9\" data-start=\"1437\" data-end=\"1458\">Wind power projects<\/li>\n<li data-section-id=\"1t46jo1\" data-start=\"1459\" data-end=\"1501\">Mining and mineral processing facilities<\/li>\n<li data-section-id=\"13wjk53\" data-start=\"1502\" data-end=\"1516\">Steel plants<\/li>\n<li data-section-id=\"1j3p1q8\" data-start=\"1517\" data-end=\"1545\">Large industrial factories<\/li>\n<li data-section-id=\"lieply\" data-start=\"1546\" data-end=\"1576\">Infrastructure power systems<\/li>\n<\/ul>\n<p data-start=\"1578\" data-end=\"1667\">It is suitable for projects requiring continuous and reliable high-capacity power supply.<\/p>\n<hr data-start=\"1669\" data-end=\"1672\" \/>\n<h2 data-section-id=\"lwbtag\" data-start=\"1674\" data-end=\"1735\">Q4: Why does the 25000kVA transformer use copper windings?<\/h2>\n<p data-start=\"1737\" data-end=\"1836\"><strong data-start=\"1737\" data-end=\"1743\">A:<\/strong> Copper windings are selected because copper has excellent electrical and thermal properties.<\/p>\n<p data-start=\"1838\" data-end=\"1857\">Advantages include:<\/p>\n<ul data-start=\"1859\" data-end=\"2053\">\n<li data-section-id=\"v4btfk\" data-start=\"1859\" data-end=\"1891\">Higher electrical conductivity<\/li>\n<li data-section-id=\"1aveg7x\" data-start=\"1892\" data-end=\"1917\">Lower resistance losses<\/li>\n<li data-section-id=\"ybzzk9\" data-start=\"1918\" data-end=\"1943\">Better heat dissipation<\/li>\n<li data-section-id=\"5kwhp1\" data-start=\"1944\" data-end=\"1972\">Strong mechanical strength<\/li>\n<li data-section-id=\"1tfeta\" data-start=\"1973\" data-end=\"2019\">Excellent short-circuit withstand capability<\/li>\n<li data-section-id=\"63pemy\" data-start=\"2020\" data-end=\"2053\">Improved transformer efficiency<\/li>\n<\/ul>\n<p data-start=\"2055\" data-end=\"2164\">Copper winding design helps the transformer maintain stable performance during long-term high-load operation.<\/p>\n<hr data-start=\"2166\" data-end=\"2169\" \/>\n<h2 data-section-id=\"t16d45\" data-start=\"2171\" data-end=\"2242\">Q5: What voltage ratings are available for the 25000kVA transformer?<\/h2>\n<p data-start=\"2244\" data-end=\"2345\"><strong data-start=\"2244\" data-end=\"2250\">A:<\/strong> ZISHENG provides customized voltage configurations according to customer project requirements.<\/p>\n<p data-start=\"2347\" data-end=\"2378\">Common voltage ratings include:<\/p>\n<h3 data-section-id=\"1no5yob\" data-start=\"2380\" data-end=\"2402\">High Voltage Side:<\/h3>\n<ul data-start=\"2403\" data-end=\"2460\">\n<li data-section-id=\"1o2lj7\" data-start=\"2403\" data-end=\"2408\">6kV<\/li>\n<li data-section-id=\"1j29sus\" data-start=\"2409\" data-end=\"2415\">10kV<\/li>\n<li data-section-id=\"1j29tlh\" data-start=\"2416\" data-end=\"2422\">11kV<\/li>\n<li data-section-id=\"do3m4h\" data-start=\"2423\" data-end=\"2431\">13.8kV<\/li>\n<li data-section-id=\"1j2c27r\" data-start=\"2432\" data-end=\"2438\">20kV<\/li>\n<li data-section-id=\"1j2bger\" data-start=\"2439\" data-end=\"2445\">35kV<\/li>\n<li data-section-id=\"1j2ewxh\" data-start=\"2446\" data-end=\"2452\">66kV<\/li>\n<li data-section-id=\"15b5t2d\" data-start=\"2453\" data-end=\"2460\">110kV<\/li>\n<\/ul>\n<h3 data-section-id=\"1jw4ltd\" data-start=\"2462\" data-end=\"2483\">Low Voltage Side:<\/h3>\n<ul data-start=\"2484\" data-end=\"2532\">\n<li data-section-id=\"1j2dkqy\" data-start=\"2484\" data-end=\"2490\">400V<\/li>\n<li data-section-id=\"1j2dmzy\" data-start=\"2491\" data-end=\"2497\">415V<\/li>\n<li data-section-id=\"1j2ezup\" data-start=\"2498\" data-end=\"2504\">690V<\/li>\n<li data-section-id=\"8kp432\" data-start=\"2505\" data-end=\"2532\">Customized voltage levels<\/li>\n<\/ul>\n<p data-start=\"2534\" data-end=\"2630\">The voltage ratio can be designed according to local grid standards and substation requirements.<\/p>\n<hr data-start=\"2632\" data-end=\"2635\" \/>\n<h2 data-section-id=\"1qnfsvp\" data-start=\"2637\" data-end=\"2712\">Q6: What is the cooling method of the 25000kVA Oil-Immersed Transformer?<\/h2>\n<p data-start=\"2714\" data-end=\"2760\"><strong data-start=\"2714\" data-end=\"2720\">A:<\/strong> The standard cooling method is usually:<\/p>\n<p data-start=\"2762\" data-end=\"2796\"><strong data-start=\"2762\" data-end=\"2796\">ONAN (Oil Natural Air Natural)<\/strong><\/p>\n<p data-start=\"2798\" data-end=\"2861\">For higher load requirements, optional cooling methods include:<\/p>\n<p data-start=\"2863\" data-end=\"2896\"><strong data-start=\"2863\" data-end=\"2896\">ONAF (Oil Natural Air Forced)<\/strong><\/p>\n<p data-start=\"2898\" data-end=\"2923\">The cooling system helps:<\/p>\n<ul data-start=\"2925\" data-end=\"3054\">\n<li data-section-id=\"1nfljg7\" data-start=\"2925\" data-end=\"2961\">Remove heat from windings and core<\/li>\n<li data-section-id=\"1uu1d0x\" data-start=\"2962\" data-end=\"2999\">Maintain safe operating temperature<\/li>\n<li data-section-id=\"11klwqy\" data-start=\"3000\" data-end=\"3029\">Improve overload capability<\/li>\n<li data-section-id=\"jabye0\" data-start=\"3030\" data-end=\"3054\">Extend insulation life<\/li>\n<\/ul>\n<hr data-start=\"3056\" data-end=\"3059\" \/>\n<h2 data-section-id=\"11o4clq\" data-start=\"3061\" data-end=\"3162\">Q7: What is the difference between a 25000kVA Oil-Immersed Transformer and a Dry Type Transformer?<\/h2>\n<p data-start=\"3164\" data-end=\"3196\"><strong data-start=\"3164\" data-end=\"3170\">A:<\/strong> The main differences are:<\/p>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"3198\" data-end=\"3639\">\n<thead data-start=\"3198\" data-end=\"3256\">\n<tr data-start=\"3198\" data-end=\"3256\">\n<th class=\"last:pe-10\" data-start=\"3198\" data-end=\"3205\" data-col-size=\"sm\">Item<\/th>\n<th class=\"last:pe-10\" data-start=\"3205\" data-end=\"3232\" data-col-size=\"sm\">Oil-Immersed Transformer<\/th>\n<th class=\"last:pe-10\" data-start=\"3232\" data-end=\"3256\" data-col-size=\"sm\">Dry Type Transformer<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"3271\" data-end=\"3639\">\n<tr data-start=\"3271\" data-end=\"3330\">\n<td data-start=\"3271\" data-end=\"3288\" data-col-size=\"sm\">Cooling Medium<\/td>\n<td data-col-size=\"sm\" data-start=\"3288\" data-end=\"3306\">Transformer oil<\/td>\n<td data-col-size=\"sm\" data-start=\"3306\" data-end=\"3330\">Air\/resin insulation<\/td>\n<\/tr>\n<tr data-start=\"3331\" data-end=\"3414\">\n<td data-start=\"3331\" data-end=\"3348\" data-col-size=\"sm\">Capacity Range<\/td>\n<td data-col-size=\"sm\" data-start=\"3348\" data-end=\"3378\">Suitable for large capacity<\/td>\n<td data-col-size=\"sm\" data-start=\"3378\" data-end=\"3414\">Mainly small and medium capacity<\/td>\n<\/tr>\n<tr data-start=\"3415\" data-end=\"3475\">\n<td data-start=\"3415\" data-end=\"3430\" data-col-size=\"sm\">Installation<\/td>\n<td data-start=\"3430\" data-end=\"3452\" data-col-size=\"sm\">Outdoor substations<\/td>\n<td data-start=\"3452\" data-end=\"3475\" data-col-size=\"sm\">Indoor applications<\/td>\n<\/tr>\n<tr data-start=\"3476\" data-end=\"3515\">\n<td data-start=\"3476\" data-end=\"3495\" data-col-size=\"sm\">Heat Dissipation<\/td>\n<td data-col-size=\"sm\" data-start=\"3495\" data-end=\"3507\">Excellent<\/td>\n<td data-col-size=\"sm\" data-start=\"3507\" data-end=\"3515\">Good<\/td>\n<\/tr>\n<tr data-start=\"3516\" data-end=\"3559\">\n<td data-start=\"3516\" data-end=\"3538\" data-col-size=\"sm\">Overload Capability<\/td>\n<td data-start=\"3538\" data-end=\"3547\" data-col-size=\"sm\">Strong<\/td>\n<td data-col-size=\"sm\" data-start=\"3547\" data-end=\"3559\">Moderate<\/td>\n<\/tr>\n<tr data-start=\"3560\" data-end=\"3639\">\n<td data-start=\"3560\" data-end=\"3574\" data-col-size=\"sm\">Application<\/td>\n<td data-start=\"3574\" data-end=\"3612\" data-col-size=\"sm\">Power grids, industrial substations<\/td>\n<td data-start=\"3612\" data-end=\"3639\" data-col-size=\"sm\">Buildings, data centers<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"3641\" data-end=\"3772\">For 25MVA applications, oil-immersed transformers are commonly selected due to their excellent cooling performance and reliability.<\/p>\n<hr data-start=\"3774\" data-end=\"3777\" \/>\n<h2 data-section-id=\"1tqi0mi\" data-start=\"3779\" data-end=\"3829\">Q8: Can the 25000kVA transformer be customized?<\/h2>\n<p data-start=\"3831\" data-end=\"3927\"><strong data-start=\"3831\" data-end=\"3837\">A:<\/strong> Yes. ZISHENG provides customized transformer solutions according to project requirements.<\/p>\n<p data-start=\"3929\" data-end=\"3959\">Customization options include:<\/p>\n<ul data-start=\"3961\" data-end=\"4166\">\n<li data-section-id=\"1g66igc\" data-start=\"3961\" data-end=\"3976\">Rated voltage<\/li>\n<li data-section-id=\"1hrce0x\" data-start=\"3977\" data-end=\"4000\">Frequency (50Hz\/60Hz)<\/li>\n<li data-section-id=\"1jhb2np\" data-start=\"4001\" data-end=\"4024\">Copper winding design<\/li>\n<li data-section-id=\"1y4t33i\" data-start=\"4025\" data-end=\"4039\">Vector group<\/li>\n<li data-section-id=\"10fztfc\" data-start=\"4040\" data-end=\"4065\">Short-circuit impedance<\/li>\n<li data-section-id=\"1gstmu0\" data-start=\"4066\" data-end=\"4082\">Cooling method<\/li>\n<li data-section-id=\"18xd3kx\" data-start=\"4083\" data-end=\"4101\">Tap changer type<\/li>\n<li data-section-id=\"1sby1hq\" data-start=\"4102\" data-end=\"4121\">Protection system<\/li>\n<li data-section-id=\"7xt699\" data-start=\"4122\" data-end=\"4138\">Tank structure<\/li>\n<li data-section-id=\"1s1vvnc\" data-start=\"4139\" data-end=\"4166\">Installation requirements<\/li>\n<\/ul>\n<hr data-start=\"4168\" data-end=\"4171\" \/>\n<h2 data-section-id=\"a8k68\" data-start=\"4173\" data-end=\"4237\">Q9: What transformer oil is used in the 25000kVA transformer?<\/h2>\n<p data-start=\"4239\" data-end=\"4339\"><strong data-start=\"4239\" data-end=\"4245\">A:<\/strong> The transformer uses high-quality insulating oil designed for power transformer applications.<\/p>\n<p data-start=\"4341\" data-end=\"4366\">Transformer oil provides:<\/p>\n<ul data-start=\"4368\" data-end=\"4493\">\n<li data-section-id=\"1fi0ceu\" data-start=\"4368\" data-end=\"4391\">Electrical insulation<\/li>\n<li data-section-id=\"13hyb7f\" data-start=\"4392\" data-end=\"4407\">Heat transfer<\/li>\n<li data-section-id=\"17oxjr3\" data-start=\"4408\" data-end=\"4429\">Cooling performance<\/li>\n<li data-section-id=\"oks8wz\" data-start=\"4430\" data-end=\"4461\">Internal component protection<\/li>\n<li data-section-id=\"yarhdz\" data-start=\"4462\" data-end=\"4493\">Improved transformer lifespan<\/li>\n<\/ul>\n<p data-start=\"4495\" data-end=\"4581\">The oil quality is tested during production to ensure reliable insulation performance.<\/p>\n<hr data-start=\"4583\" data-end=\"4586\" \/>\n<h2 data-section-id=\"1c1tegg\" data-start=\"4588\" data-end=\"4638\">Q10: What protection accessories are available?<\/h2>\n<p data-start=\"4640\" data-end=\"4724\"><strong data-start=\"4640\" data-end=\"4646\">A:<\/strong> ZISHENG can provide various protection and monitoring accessories, including:<\/p>\n<ul data-start=\"4726\" data-end=\"4905\">\n<li data-section-id=\"1embb6u\" data-start=\"4726\" data-end=\"4742\">Buchholz relay<\/li>\n<li data-section-id=\"1axeqkv\" data-start=\"4743\" data-end=\"4770\">Oil temperature indicator<\/li>\n<li data-section-id=\"1gthgs5\" data-start=\"4771\" data-end=\"4792\">Oil level indicator<\/li>\n<li data-section-id=\"muahk4\" data-start=\"4793\" data-end=\"4817\">Pressure relief device<\/li>\n<li data-section-id=\"1lhq24s\" data-start=\"4818\" data-end=\"4838\">Lightning arrester<\/li>\n<li data-section-id=\"1umv7j1\" data-start=\"4839\" data-end=\"4853\">Cooling fans<\/li>\n<li data-section-id=\"lxnyox\" data-start=\"4854\" data-end=\"4873\">Monitoring system<\/li>\n<li data-section-id=\"1c3nhpj\" data-start=\"4874\" data-end=\"4905\">Online temperature monitoring<\/li>\n<\/ul>\n<p data-start=\"4907\" data-end=\"5002\">These accessories improve operational safety and help operators monitor transformer conditions.<\/p>\n<hr data-start=\"5004\" data-end=\"5007\" \/>\n<h2 data-section-id=\"u9gz47\" data-start=\"5009\" data-end=\"5063\">Q11: Can the 25000kVA transformer operate outdoors?<\/h2>\n<p data-start=\"5065\" data-end=\"5141\"><strong data-start=\"5065\" data-end=\"5071\">A:<\/strong> Yes. The transformer is designed for outdoor substation installation.<\/p>\n<p data-start=\"5143\" data-end=\"5174\">The outdoor structure provides:<\/p>\n<ul data-start=\"5176\" data-end=\"5298\">\n<li data-section-id=\"1dhs09f\" data-start=\"5176\" data-end=\"5196\">Weather resistance<\/li>\n<li data-section-id=\"1g9fqrp\" data-start=\"5197\" data-end=\"5218\">Moisture protection<\/li>\n<li data-section-id=\"x5lihr\" data-start=\"5219\" data-end=\"5246\">Anti-corrosion capability<\/li>\n<li data-section-id=\"5kwhp1\" data-start=\"5247\" data-end=\"5275\">Strong mechanical strength<\/li>\n<li data-section-id=\"1u5w4v5\" data-start=\"5276\" data-end=\"5298\">Reliable oil sealing<\/li>\n<\/ul>\n<p data-start=\"5300\" data-end=\"5350\">It can operate in various environments, including:<\/p>\n<ul data-start=\"5352\" data-end=\"5440\">\n<li data-section-id=\"1dwq9j1\" data-start=\"5352\" data-end=\"5370\">Tropical regions<\/li>\n<li data-section-id=\"11m5s8z\" data-start=\"5371\" data-end=\"5395\">High-temperature areas<\/li>\n<li data-section-id=\"199z6tn\" data-start=\"5396\" data-end=\"5414\">Industrial areas<\/li>\n<li data-section-id=\"1e6o464\" data-start=\"5415\" data-end=\"5440\">High-humidity locations<\/li>\n<\/ul>\n<hr data-start=\"5442\" data-end=\"5445\" \/>\n<h2 data-section-id=\"1ddu4pq\" data-start=\"5447\" data-end=\"5496\">Q12: What tests are performed before delivery?<\/h2>\n<p data-start=\"5498\" data-end=\"5572\"><strong data-start=\"5498\" data-end=\"5504\">A:<\/strong> Each ZISHENG 25000kVA transformer undergoes strict factory testing.<\/p>\n<p data-start=\"5574\" data-end=\"5591\">Testing includes:<\/p>\n<ul data-start=\"5593\" data-end=\"5837\">\n<li data-section-id=\"13jcszt\" data-start=\"5593\" data-end=\"5618\">Winding resistance test<\/li>\n<li data-section-id=\"19g9fot\" data-start=\"5619\" data-end=\"5647\">Insulation resistance test<\/li>\n<li data-section-id=\"gu8nj1\" data-start=\"5648\" data-end=\"5668\">Voltage ratio test<\/li>\n<li data-section-id=\"1lot3kn\" data-start=\"5669\" data-end=\"5688\">No-load loss test<\/li>\n<li data-section-id=\"9opfkr\" data-start=\"5689\" data-end=\"5705\">Load loss test<\/li>\n<li data-section-id=\"i83fx1\" data-start=\"5706\" data-end=\"5732\">Dielectric strength test<\/li>\n<li data-section-id=\"70rzy7\" data-start=\"5733\" data-end=\"5756\">Temperature rise test<\/li>\n<li data-section-id=\"f88wac\" data-start=\"5757\" data-end=\"5775\">Oil leakage test<\/li>\n<li data-section-id=\"1d0g0aq\" data-start=\"5776\" data-end=\"5806\">Transformer oil quality test<\/li>\n<li data-section-id=\"zme1gw\" data-start=\"5807\" data-end=\"5837\">Protection system inspection<\/li>\n<\/ul>\n<p data-start=\"5839\" data-end=\"5892\">Only qualified transformers are shipped to customers.<\/p>\n<hr data-start=\"5894\" data-end=\"5897\" \/>\n<h2 data-section-id=\"10acglu\" data-start=\"5899\" data-end=\"5963\">Q13: What standards can the 25000kVA transformer comply with?<\/h2>\n<p data-start=\"5965\" data-end=\"6026\"><strong data-start=\"5965\" data-end=\"5971\">A:<\/strong> ZISHENG transformers can be manufactured according to:<\/p>\n<ul data-start=\"6028\" data-end=\"6122\">\n<li data-section-id=\"ocarov\" data-start=\"6028\" data-end=\"6043\">IEC standards<\/li>\n<li data-section-id=\"1qy8or9\" data-start=\"6044\" data-end=\"6060\">ANSI standards<\/li>\n<li data-section-id=\"195zzu9\" data-start=\"6061\" data-end=\"6096\">Customer technical specifications<\/li>\n<li data-section-id=\"1yvih9t\" data-start=\"6097\" data-end=\"6122\">Local grid requirements<\/li>\n<\/ul>\n<p data-start=\"6124\" data-end=\"6197\">The transformer design can be adapted to different international markets.<\/p>\n<hr data-start=\"6199\" data-end=\"6202\" \/>\n<h2 data-section-id=\"cxp9yp\" data-start=\"6204\" data-end=\"6281\">Q14: What maintenance is required for a 25000kVA Oil-Immersed Transformer?<\/h2>\n<p data-start=\"6283\" data-end=\"6323\"><strong data-start=\"6283\" data-end=\"6289\">A:<\/strong> Recommended maintenance includes:<\/p>\n<ul data-start=\"6325\" data-end=\"6523\">\n<li data-section-id=\"1vdj2gl\" data-start=\"6325\" data-end=\"6358\">Regular transformer oil testing<\/li>\n<li data-section-id=\"hiw5n6\" data-start=\"6359\" data-end=\"6379\">Checking oil level<\/li>\n<li data-section-id=\"185lizl\" data-start=\"6380\" data-end=\"6401\">Inspecting bushings<\/li>\n<li data-section-id=\"1jf07cb\" data-start=\"6402\" data-end=\"6430\">Checking cooling equipment<\/li>\n<li data-section-id=\"1tl3mae\" data-start=\"6431\" data-end=\"6462\">Inspecting protection devices<\/li>\n<li data-section-id=\"5w9x4m\" data-start=\"6463\" data-end=\"6495\">Testing insulation performance<\/li>\n<li data-section-id=\"bxw8ha\" data-start=\"6496\" data-end=\"6523\">Checking grounding system<\/li>\n<\/ul>\n<p data-start=\"6525\" data-end=\"6608\">Proper maintenance helps ensure safe operation and extend transformer service life.<\/p>\n<hr data-start=\"6610\" data-end=\"6613\" \/>\n<h2 data-section-id=\"ubnz5b\" data-start=\"6615\" data-end=\"6694\">Q15: What is the service life of a 25000kVA Oil-Immersed Copper Transformer?<\/h2>\n<p data-start=\"6696\" data-end=\"6840\"><strong data-start=\"6696\" data-end=\"6702\">A:<\/strong> A high-quality 25000kVA Oil-Immersed Copper Transformer can provide decades of reliable operation when properly installed and maintained.<\/p>\n<p data-start=\"6842\" data-end=\"6866\">Service life depends on:<\/p>\n<ul data-start=\"6868\" data-end=\"6997\">\n<li data-section-id=\"y7w00l\" data-start=\"6868\" data-end=\"6890\">Operating conditions<\/li>\n<li data-section-id=\"1er8ni0\" data-start=\"6891\" data-end=\"6903\">Load level<\/li>\n<li data-section-id=\"17oxjr3\" data-start=\"6904\" data-end=\"6925\">Cooling performance<\/li>\n<li data-section-id=\"1m3zy40\" data-start=\"6926\" data-end=\"6952\">Environmental conditions<\/li>\n<li data-section-id=\"18ylh7c\" data-start=\"6953\" data-end=\"6974\">Maintenance quality<\/li>\n<li data-section-id=\"7k9j3f\" data-start=\"6975\" data-end=\"6997\">Insulation condition<\/li>\n<\/ul>\n<p data-start=\"6999\" data-end=\"7102\">ZISHENG uses high-quality materials and strict manufacturing processes to ensure long-term reliability.<\/p>\n<hr data-start=\"7104\" data-end=\"7107\" \/>\n<h2 data-section-id=\"1d4k02x\" data-start=\"7109\" data-end=\"7177\">Q16: Why choose ZISHENG 25000kVA Oil-Immersed Copper Transformer?<\/h2>\n<p data-start=\"7179\" data-end=\"7203\"><strong data-start=\"7179\" data-end=\"7185\">A:<\/strong> ZISHENG provides:<\/p>\n<ul data-start=\"7205\" data-end=\"7509\">\n<li data-section-id=\"1xjfp7s\" data-start=\"7205\" data-end=\"7256\">Professional transformer manufacturing capability<\/li>\n<li data-section-id=\"154sagi\" data-start=\"7257\" data-end=\"7301\">Experience in international power projects<\/li>\n<li data-section-id=\"8hblyn\" data-start=\"7302\" data-end=\"7342\">High-quality copper winding technology<\/li>\n<li data-section-id=\"2iw5hb\" data-start=\"7343\" data-end=\"7374\">Advanced production equipment<\/li>\n<li data-section-id=\"drxkcs\" data-start=\"7375\" data-end=\"7406\">Strict quality control system<\/li>\n<li data-section-id=\"1tua26y\" data-start=\"7407\" data-end=\"7441\">Customized engineering solutions<\/li>\n<li data-section-id=\"7qao7w\" data-start=\"7442\" data-end=\"7472\">Reliable delivery capability<\/li>\n<li data-section-id=\"eb3ucz\" data-start=\"7473\" data-end=\"7509\">Competitive factory-direct pricing<\/li>\n<\/ul>\n<p data-start=\"7511\" data-end=\"7765\" data-is-last-node=\"\" data-is-only-node=\"\">ZISHENG <strong data-start=\"7519\" data-end=\"7578\">25000kVA Oil-Immersed Copper Transformer for Substation<\/strong> is a reliable high-capacity power solution for utility companies, EPC contractors, renewable energy developers, industrial enterprises, and large-scale infrastructure projects worldwide.<\/p>","protected":false},"excerpt":{"rendered":"<p>The 25,000kVA oil-immersed copper transformer is engineered for high-standard power distribution in large industrial facilities, utility networks, and high-voltage substations. Built with premium pure copper windings, it delivers exceptional electrical conductivity, reduced losses, and long-term operational stability. The oil-immersed cooling system ensures efficient heat dissipation, allowing the transformer to perform reliably under continuous heavy load conditions.<\/p>","protected":false},"featured_media":1649,"template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[],"product_cat":[72],"product_tag":[],"class_list":["post-1653","product","type-product","status-publish","has-post-thumbnail","product_cat-substation-transformer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product\/1653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/media\/1649"}],"wp:attachment":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/media?parent=1653"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1653"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1653"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}