{"id":1856,"date":"2026-08-28T14:49:13","date_gmt":"2026-08-28T06:49:13","guid":{"rendered":"https:\/\/www.zishengelectric.com\/?post_type=product&#038;p=1856"},"modified":"2026-09-15T17:40:47","modified_gmt":"2026-09-15T09:40:47","slug":"100kva-dry-type-transformer","status":"publish","type":"product","link":"https:\/\/www.zishengelectric.com\/ar\/product\/100kva-dry-type-transformer","title":{"rendered":"100kVA Dry Type Transformer"},"content":{"rendered":"<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"97\" data-end=\"379\">The <strong data-start=\"101\" data-end=\"132\">100kVA Dry Type Transformer<\/strong> is a three-phase, oil-free transformer designed for safe and reliable electrical power distribution. It uses air as the cooling medium and can be supplied in <strong data-start=\"291\" data-end=\"344\">cast resin, VPI, or other dry-type configurations<\/strong> according to project requirements.<\/p>\n<p data-start=\"381\" data-end=\"604\">A typical configuration is <strong data-start=\"408\" data-end=\"445\">10kV \/ 0.4kV, 100kVA, 50Hz, Dyn11<\/strong>, although the primary and secondary voltages, vector group, impedance, enclosure and other parameters can be customized.<\/p>\n<p data-start=\"606\" data-end=\"756\">The transformer complies with <strong data-start=\"636\" data-end=\"652\">IEC 60076-11<\/strong>, the international standard covering dry-type power transformers.<\/p>\n<hr data-start=\"758\" data-end=\"761\" \/>\n<h1 data-section-id=\"zdojif\" data-start=\"763\" data-end=\"792\">2. Technical Specifications<\/h1>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"794\" data-end=\"1578\">\n<thead data-start=\"794\" data-end=\"832\">\n<tr data-start=\"794\" data-end=\"832\">\n<th class=\"last:pe-10\" data-start=\"794\" data-end=\"806\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"806\" data-end=\"832\" data-col-size=\"md\">Standard Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"843\" data-end=\"1578\">\n<tr data-start=\"843\" data-end=\"875\">\n<td data-start=\"843\" data-end=\"864\" data-col-size=\"sm\"><strong data-start=\"845\" data-end=\"863\">Rated Capacity<\/strong><\/td>\n<td data-start=\"864\" data-end=\"875\" data-col-size=\"md\">100 kVA<\/td>\n<\/tr>\n<tr data-start=\"876\" data-end=\"903\">\n<td data-start=\"876\" data-end=\"888\" data-col-size=\"sm\"><strong data-start=\"878\" data-end=\"887\">Phase<\/strong><\/td>\n<td data-start=\"888\" data-end=\"903\" data-col-size=\"md\">Three Phase<\/td>\n<\/tr>\n<tr data-start=\"904\" data-end=\"934\">\n<td data-start=\"904\" data-end=\"920\" data-col-size=\"sm\"><strong data-start=\"906\" data-end=\"919\">Frequency<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"920\" data-end=\"934\">50 \/ 60 Hz<\/td>\n<\/tr>\n<tr data-start=\"935\" data-end=\"961\">\n<td data-start=\"935\" data-end=\"952\" data-col-size=\"sm\"><strong data-start=\"937\" data-end=\"951\">HV Voltage<\/strong><\/td>\n<td data-start=\"952\" data-end=\"961\" data-col-size=\"md\">10 kV<\/td>\n<\/tr>\n<tr data-start=\"962\" data-end=\"997\">\n<td data-start=\"962\" data-end=\"979\" data-col-size=\"sm\"><strong data-start=\"964\" data-end=\"978\">LV Voltage<\/strong><\/td>\n<td data-start=\"979\" data-end=\"997\" data-col-size=\"md\">0.4 kV \/ 400 V<\/td>\n<\/tr>\n<tr data-start=\"998\" data-end=\"1033\">\n<td data-start=\"998\" data-end=\"1018\" data-col-size=\"sm\"><strong data-start=\"1000\" data-end=\"1017\">Voltage Ratio<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1018\" data-end=\"1033\">10 \/ 0.4 kV<\/td>\n<\/tr>\n<tr data-start=\"1034\" data-end=\"1062\">\n<td data-start=\"1034\" data-end=\"1053\" data-col-size=\"sm\"><strong data-start=\"1036\" data-end=\"1052\">Vector Group<\/strong><\/td>\n<td data-start=\"1053\" data-end=\"1062\" data-col-size=\"md\">Dyn11<\/td>\n<\/tr>\n<tr data-start=\"1063\" data-end=\"1095\">\n<td data-start=\"1063\" data-end=\"1084\" data-col-size=\"sm\"><strong data-start=\"1065\" data-end=\"1083\">Cooling Method<\/strong><\/td>\n<td data-start=\"1084\" data-end=\"1095\" data-col-size=\"md\">AN \/ AF<\/td>\n<\/tr>\n<tr data-start=\"1096\" data-end=\"1132\">\n<td data-start=\"1096\" data-end=\"1118\" data-col-size=\"sm\"><strong data-start=\"1098\" data-end=\"1117\">Insulation Type<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1118\" data-end=\"1132\">Cast Resin<\/td>\n<\/tr>\n<tr data-start=\"1133\" data-end=\"1165\">\n<td data-start=\"1133\" data-end=\"1156\" data-col-size=\"sm\"><strong data-start=\"1135\" data-end=\"1155\">Insulation Class<\/strong><\/td>\n<td data-start=\"1156\" data-end=\"1165\" data-col-size=\"md\">F \/ H<\/td>\n<\/tr>\n<tr data-start=\"1166\" data-end=\"1196\">\n<td data-start=\"1166\" data-end=\"1182\" data-col-size=\"sm\"><strong data-start=\"1168\" data-end=\"1181\">Impedance<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1182\" data-end=\"1196\">4% typical<\/td>\n<\/tr>\n<tr data-start=\"1197\" data-end=\"1234\">\n<td data-start=\"1197\" data-end=\"1214\" data-col-size=\"sm\"><strong data-start=\"1199\" data-end=\"1213\">HV Tapping<\/strong><\/td>\n<td data-start=\"1214\" data-end=\"1234\" data-col-size=\"md\">\u00b12 \u00d7 2.5% or \u00b15%<\/td>\n<\/tr>\n<tr data-start=\"1235\" data-end=\"1279\">\n<td data-start=\"1235\" data-end=\"1258\" data-col-size=\"sm\"><strong data-start=\"1237\" data-end=\"1257\">Winding Material<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1258\" data-end=\"1279\">Copper \/ Aluminum<\/td>\n<\/tr>\n<tr data-start=\"1280\" data-end=\"1321\">\n<td data-start=\"1280\" data-end=\"1303\" data-col-size=\"sm\"><strong data-start=\"1282\" data-end=\"1302\">Temperature Rise<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1303\" data-end=\"1321\">\u2264100 K typical<\/td>\n<\/tr>\n<tr data-start=\"1322\" data-end=\"1376\">\n<td data-start=\"1322\" data-end=\"1341\" data-col-size=\"sm\"><strong data-start=\"1324\" data-end=\"1340\">Installation<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1341\" data-end=\"1376\">Indoor \/ Outdoor with enclosure<\/td>\n<\/tr>\n<tr data-start=\"1377\" data-end=\"1428\">\n<td data-start=\"1377\" data-end=\"1394\" data-col-size=\"sm\"><strong data-start=\"1379\" data-end=\"1393\">Protection<\/strong><\/td>\n<td data-col-size=\"md\" data-start=\"1394\" data-end=\"1428\">IP00 \/ IP20 \/ IP21 \/ IP31 etc.<\/td>\n<\/tr>\n<tr data-start=\"1429\" data-end=\"1460\">\n<td data-start=\"1429\" data-end=\"1444\" data-col-size=\"sm\"><strong data-start=\"1431\" data-end=\"1443\">Standard<\/strong><\/td>\n<td data-start=\"1444\" data-end=\"1460\" data-col-size=\"md\">IEC 60076-11<\/td>\n<\/tr>\n<tr data-start=\"1461\" data-end=\"1515\">\n<td data-start=\"1461\" data-end=\"1487\" data-col-size=\"sm\"><strong data-start=\"1463\" data-end=\"1486\">Ambient Temperature<\/strong><\/td>\n<td data-start=\"1487\" data-end=\"1515\" data-col-size=\"md\">Typically -25\u00b0C to +40\u00b0C<\/td>\n<\/tr>\n<tr data-start=\"1516\" data-end=\"1578\">\n<td data-start=\"1516\" data-end=\"1531\" data-col-size=\"sm\"><strong data-start=\"1518\" data-end=\"1530\">Altitude<\/strong><\/td>\n<td data-start=\"1531\" data-end=\"1578\" data-col-size=\"md\">\u22641000 m standard; higher altitude available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"1580\" data-end=\"1842\">Actual loss, dimensions, weight, noise level and other values should be finalized according to the selected design and applicable efficiency standard. Published 100kVA designs show considerable variation in these parameters.<\/p>\n<hr data-start=\"1844\" data-end=\"1847\" \/>\n<h1 data-section-id=\"im3unm\" data-start=\"1849\" data-end=\"1890\">3. Typical 100kVA 10kV\/0.4kV Parameters<\/h1>\n<p data-start=\"1892\" data-end=\"1990\">For a standard <strong data-start=\"1907\" data-end=\"1932\">100kVA \/ 10kV \/ 0.4kV<\/strong> transformer, a representative technical configuration is:<\/p>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1992\" data-end=\"2423\">\n<thead data-start=\"1992\" data-end=\"2016\">\n<tr data-start=\"1992\" data-end=\"2016\">\n<th class=\"last:pe-10\" data-start=\"1992\" data-end=\"1999\" data-col-size=\"sm\">Item<\/th>\n<th class=\"last:pe-10\" data-start=\"1999\" data-end=\"2016\" data-col-size=\"sm\">Typical Value<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2028\" data-end=\"2423\">\n<tr data-start=\"2028\" data-end=\"2053\">\n<td data-start=\"2028\" data-end=\"2042\" data-col-size=\"sm\">Rated Power<\/td>\n<td data-start=\"2042\" data-end=\"2053\" data-col-size=\"sm\">100 kVA<\/td>\n<\/tr>\n<tr data-start=\"2054\" data-end=\"2068\">\n<td data-start=\"2054\" data-end=\"2059\" data-col-size=\"sm\">HV<\/td>\n<td data-start=\"2059\" data-end=\"2068\" data-col-size=\"sm\">10 kV<\/td>\n<\/tr>\n<tr data-start=\"2069\" data-end=\"2083\">\n<td data-start=\"2069\" data-end=\"2074\" data-col-size=\"sm\">LV<\/td>\n<td data-start=\"2074\" data-end=\"2083\" data-col-size=\"sm\">400 V<\/td>\n<\/tr>\n<tr data-start=\"2084\" data-end=\"2105\">\n<td data-start=\"2084\" data-end=\"2096\" data-col-size=\"sm\">Frequency<\/td>\n<td data-start=\"2096\" data-end=\"2105\" data-col-size=\"sm\">50 Hz<\/td>\n<\/tr>\n<tr data-start=\"2106\" data-end=\"2130\">\n<td data-start=\"2106\" data-end=\"2121\" data-col-size=\"sm\">Vector Group<\/td>\n<td data-start=\"2121\" data-end=\"2130\" data-col-size=\"sm\">Dyn11<\/td>\n<\/tr>\n<tr data-start=\"2131\" data-end=\"2149\">\n<td data-start=\"2131\" data-end=\"2143\" data-col-size=\"sm\">Impedance<\/td>\n<td data-col-size=\"sm\" data-start=\"2143\" data-end=\"2149\">4%<\/td>\n<\/tr>\n<tr data-start=\"2150\" data-end=\"2186\">\n<td data-start=\"2150\" data-end=\"2165\" data-col-size=\"sm\">No-load Loss<\/td>\n<td data-start=\"2165\" data-end=\"2186\" data-col-size=\"sm\">Approx. 200\u2013400 W<\/td>\n<\/tr>\n<tr data-start=\"2187\" data-end=\"2221\">\n<td data-start=\"2187\" data-end=\"2199\" data-col-size=\"sm\">Load Loss<\/td>\n<td data-start=\"2199\" data-end=\"2221\" data-col-size=\"sm\">Approx. 1.4\u20131.8 kW<\/td>\n<\/tr>\n<tr data-start=\"2222\" data-end=\"2238\">\n<td data-start=\"2222\" data-end=\"2232\" data-col-size=\"sm\">Cooling<\/td>\n<td data-col-size=\"sm\" data-start=\"2232\" data-end=\"2238\">AN<\/td>\n<\/tr>\n<tr data-start=\"2239\" data-end=\"2263\">\n<td data-start=\"2239\" data-end=\"2252\" data-col-size=\"sm\">Insulation<\/td>\n<td data-start=\"2252\" data-end=\"2263\" data-col-size=\"sm\">Class F<\/td>\n<\/tr>\n<tr data-start=\"2264\" data-end=\"2293\">\n<td data-start=\"2264\" data-end=\"2283\" data-col-size=\"sm\">Temperature Rise<\/td>\n<td data-start=\"2283\" data-end=\"2293\" data-col-size=\"sm\">\u2264100 K<\/td>\n<\/tr>\n<tr data-start=\"2294\" data-end=\"2316\">\n<td data-start=\"2294\" data-end=\"2303\" data-col-size=\"sm\">HV Tap<\/td>\n<td data-start=\"2303\" data-end=\"2316\" data-col-size=\"sm\">\u00b12 \u00d7 2.5%<\/td>\n<\/tr>\n<tr data-start=\"2317\" data-end=\"2348\">\n<td data-start=\"2317\" data-end=\"2325\" data-col-size=\"sm\">Noise<\/td>\n<td data-start=\"2325\" data-end=\"2348\" data-col-size=\"sm\">Approx. 50\u201360 dB(A)<\/td>\n<\/tr>\n<tr data-start=\"2349\" data-end=\"2391\">\n<td data-start=\"2349\" data-end=\"2356\" data-col-size=\"sm\">Core<\/td>\n<td data-start=\"2356\" data-end=\"2391\" data-col-size=\"sm\">Grain-oriented electrical steel<\/td>\n<\/tr>\n<tr data-start=\"2392\" data-end=\"2423\">\n<td data-start=\"2392\" data-end=\"2402\" data-col-size=\"sm\">Winding<\/td>\n<td data-start=\"2402\" data-end=\"2423\" data-col-size=\"sm\">Copper \/ Aluminum<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"2425\" data-end=\"2752\">For example, published 100kVA designs list 220W no-load loss and 1,400W load loss, while other IEC-oriented designs specify 252W and 1,800W respectively. This demonstrates why the final datasheet should use the manufacturer&#8217;s project-specific guaranteed values rather than generic figures.<\/p>\n<hr data-start=\"2754\" data-end=\"2757\" \/>\n<h1 data-section-id=\"103db74\" data-start=\"2759\" data-end=\"2777\">4. Main Features<\/h1>\n<h3 data-section-id=\"17gght3\" data-start=\"2779\" data-end=\"2798\">Oil-Free Design<\/h3>\n<p data-start=\"2799\" data-end=\"2911\">No transformer oil is required, eliminating oil leakage and significantly reducing fire and environmental risks.<\/p>\n<h3 data-section-id=\"5qfxnw\" data-start=\"2913\" data-end=\"2933\">High Fire Safety<\/h3>\n<p data-start=\"2934\" data-end=\"3074\">Cast-resin insulation provides strong fire-retardant characteristics and is particularly suitable for buildings and indoor electrical rooms.<\/p>\n<h3 data-section-id=\"1juax8v\" data-start=\"3076\" data-end=\"3095\">Low Maintenance<\/h3>\n<p data-start=\"3096\" data-end=\"3235\">The dry-type structure eliminates oil testing, oil replacement and many maintenance requirements associated with oil-immersed transformers.<\/p>\n<h3 data-section-id=\"1h4real\" data-start=\"3237\" data-end=\"3265\">High Insulation Strength<\/h3>\n<p data-start=\"3266\" data-end=\"3371\">Vacuum-cast epoxy resin provides strong electrical insulation and mechanical protection for the windings.<\/p>\n<h3 data-section-id=\"5fpiq3\" data-start=\"3373\" data-end=\"3409\">Excellent Short-Circuit Strength<\/h3>\n<p data-start=\"3410\" data-end=\"3534\">The cast windings have strong mechanical stability and can withstand electromagnetic forces during short-circuit conditions.<\/p>\n<h3 data-section-id=\"1mcluj0\" data-start=\"3536\" data-end=\"3549\">Low Noise<\/h3>\n<p data-start=\"3550\" data-end=\"3698\">Optimized magnetic core and winding structures help reduce operating noise, making the transformer suitable for commercial and industrial buildings.<\/p>\n<h3 data-section-id=\"t88vxf\" data-start=\"3700\" data-end=\"3726\">Flexible Configuration<\/h3>\n<p data-start=\"3727\" data-end=\"3851\">HV\/LV voltage, vector group, impedance, winding material, enclosure, cooling method and monitoring system can be customized.<\/p>\n<hr data-start=\"3853\" data-end=\"3856\" \/>\n<h1 data-section-id=\"12nhpvf\" data-start=\"3858\" data-end=\"3887\">5. Transformer Construction<\/h1>\n<h2 data-section-id=\"1xvztvi\" data-start=\"3889\" data-end=\"3896\">Core<\/h2>\n<p data-start=\"3898\" data-end=\"4031\">The transformer core is manufactured from high-quality <strong data-start=\"3953\" data-end=\"3988\">grain-oriented electrical steel<\/strong> with optimized magnetic flux distribution.<\/p>\n<p data-start=\"4033\" data-end=\"4063\">Typical construction includes:<\/p>\n<ul data-start=\"4065\" data-end=\"4239\">\n<li data-section-id=\"99m38v\" data-start=\"4065\" data-end=\"4089\">Step-lap core assembly<\/li>\n<li data-section-id=\"qlytfh\" data-start=\"4090\" data-end=\"4117\">Low magnetic flux density<\/li>\n<li data-section-id=\"1q5cah1\" data-start=\"4118\" data-end=\"4140\">Reduced no-load loss<\/li>\n<li data-section-id=\"1c13u4v\" data-start=\"4141\" data-end=\"4166\">Reduced operating noise<\/li>\n<li data-section-id=\"1c0tsp4\" data-start=\"4167\" data-end=\"4193\">High mechanical strength<\/li>\n<li data-section-id=\"snfy1h\" data-start=\"4194\" data-end=\"4239\">High-quality insulation between laminations<\/li>\n<\/ul>\n<h2 data-section-id=\"41dmb4\" data-start=\"4241\" data-end=\"4264\">High-Voltage Winding<\/h2>\n<p data-start=\"4266\" data-end=\"4416\">The HV winding can use copper or aluminum conductors and is insulated using cast resin or VPI technology depending on the selected transformer design.<\/p>\n<p data-start=\"4418\" data-end=\"4525\">For cast-resin transformers, vacuum casting helps reduce internal voids and improve insulation reliability.<\/p>\n<h2 data-section-id=\"1w25jca\" data-start=\"4527\" data-end=\"4549\">Low-Voltage Winding<\/h2>\n<p data-start=\"4551\" data-end=\"4589\">The LV winding is designed to provide:<\/p>\n<ul data-start=\"4591\" data-end=\"4705\">\n<li data-section-id=\"yqf3o1\" data-start=\"4591\" data-end=\"4618\">Low electrical resistance<\/li>\n<li data-section-id=\"74xxqy\" data-start=\"4619\" data-end=\"4642\">Good heat dissipation<\/li>\n<li data-section-id=\"3jj7bb\" data-start=\"4643\" data-end=\"4676\">Strong short-circuit capability<\/li>\n<li data-section-id=\"17c36db\" data-start=\"4677\" data-end=\"4705\">Stable voltage performance<\/li>\n<\/ul>\n<h2 data-section-id=\"1bw8ust\" data-start=\"4707\" data-end=\"4732\">Epoxy Resin Insulation<\/h2>\n<p data-start=\"4734\" data-end=\"4906\">For cast-resin versions, the winding is encapsulated with epoxy resin to protect the conductor and insulation system against moisture, dust and environmental contamination.<\/p>\n<hr data-start=\"4908\" data-end=\"4911\" \/>\n<h1 data-section-id=\"mmz4z8\" data-start=\"4913\" data-end=\"4932\">6. Cooling System<\/h1>\n<p data-start=\"4934\" data-end=\"4965\">The standard cooling method is:<\/p>\n<p data-start=\"4967\" data-end=\"4987\"><strong data-start=\"4967\" data-end=\"4987\">AN \u2014 Air Natural<\/strong><\/p>\n<p data-start=\"4989\" data-end=\"5071\">Natural air circulation removes heat from the transformer during normal operation.<\/p>\n<p data-start=\"5073\" data-end=\"5085\">An optional:<\/p>\n<p data-start=\"5087\" data-end=\"5106\"><strong data-start=\"5087\" data-end=\"5106\">AF \u2014 Air Forced<\/strong><\/p>\n<p data-start=\"5108\" data-end=\"5389\">system can be installed using cooling fans. Forced-air cooling can increase the transformer&#8217;s available output under appropriate operating conditions, but the actual permissible capacity must be determined by the manufacturer&#8217;s thermal design.<\/p>\n<p data-start=\"5391\" data-end=\"5419\">Optional components include:<\/p>\n<ul data-start=\"5421\" data-end=\"5561\">\n<li data-section-id=\"1umv7j1\" data-start=\"5421\" data-end=\"5435\">Cooling fans<\/li>\n<li data-section-id=\"kect4g\" data-start=\"5436\" data-end=\"5457\">Fan control cabinet<\/li>\n<li data-section-id=\"mehy2c\" data-start=\"5458\" data-end=\"5485\">PT100 temperature sensors<\/li>\n<li data-section-id=\"11qvtxe\" data-start=\"5486\" data-end=\"5518\">Digital temperature controller<\/li>\n<li data-section-id=\"1mtz05w\" data-start=\"5519\" data-end=\"5543\">Over-temperature alarm<\/li>\n<li data-section-id=\"1mlm6qc\" data-start=\"5544\" data-end=\"5561\">Trip protection<\/li>\n<\/ul>\n<hr data-start=\"5563\" data-end=\"5566\" \/>\n<h1 data-section-id=\"ygabrz\" data-start=\"5568\" data-end=\"5595\">7. Temperature Monitoring<\/h1>\n<p data-start=\"5597\" data-end=\"5688\">A temperature monitoring system can be supplied for projects requiring enhanced protection.<\/p>\n<p data-start=\"5690\" data-end=\"5712\">Typical configuration:<\/p>\n<p data-start=\"5714\" data-end=\"5793\"><strong data-start=\"5714\" data-end=\"5793\">PT100 Sensors \u2192 Temperature Controller \u2192 Alarm \/ Trip \u2192 Cooling Fan Control<\/strong><\/p>\n<p data-start=\"5795\" data-end=\"5817\">Functions can include:<\/p>\n<ul data-start=\"5819\" data-end=\"6010\">\n<li data-section-id=\"jy9pj2\" data-start=\"5819\" data-end=\"5861\">Real-time winding temperature monitoring<\/li>\n<li data-section-id=\"11m167o\" data-start=\"5862\" data-end=\"5886\">High-temperature alarm<\/li>\n<li data-section-id=\"cjubnc\" data-start=\"5887\" data-end=\"5910\">Over-temperature trip<\/li>\n<li data-section-id=\"1pqzykc\" data-start=\"5911\" data-end=\"5935\">Automatic fan starting<\/li>\n<li data-section-id=\"1jgt71w\" data-start=\"5936\" data-end=\"5960\">Automatic fan stopping<\/li>\n<li data-section-id=\"1ij19g6\" data-start=\"5961\" data-end=\"5979\">Fault indication<\/li>\n<li data-section-id=\"1rrc9el\" data-start=\"5980\" data-end=\"6010\">RS485 \/ Modbus communication<\/li>\n<\/ul>\n<p data-start=\"6012\" data-end=\"6162\">Temperature monitoring and communication options are commonly available for modern dry-type transformer designs.<\/p>\n<hr data-start=\"6164\" data-end=\"6167\" \/>\n<h1 data-section-id=\"1912t8a\" data-start=\"6169\" data-end=\"6191\">8. Enclosure Options<\/h1>\n<p data-start=\"6193\" data-end=\"6314\">The basic transformer can be supplied as an <strong data-start=\"6237\" data-end=\"6255\">IP00 open type<\/strong> unit for installation inside a dedicated transformer room.<\/p>\n<p data-start=\"6316\" data-end=\"6382\">For greater protection, it can be equipped with a metal enclosure.<\/p>\n<p data-start=\"6384\" data-end=\"6400\">Typical options:<\/p>\n<p data-start=\"6402\" data-end=\"6431\"><strong data-start=\"6402\" data-end=\"6431\">IP20 \u2192 IP21 \u2192 IP31 \u2192 IP41<\/strong><\/p>\n<p data-start=\"6433\" data-end=\"6478\">The enclosure can be customized according to:<\/p>\n<ul data-start=\"6480\" data-end=\"6638\">\n<li data-section-id=\"1sod3t1\" data-start=\"6480\" data-end=\"6501\">Indoor installation<\/li>\n<li data-section-id=\"197umdo\" data-start=\"6502\" data-end=\"6524\">Outdoor installation<\/li>\n<li data-section-id=\"1nfujk1\" data-start=\"6525\" data-end=\"6545\">Dusty environments<\/li>\n<li data-section-id=\"14p627d\" data-start=\"6546\" data-end=\"6571\">Industrial environments<\/li>\n<li data-section-id=\"1mg7p3f\" data-start=\"6572\" data-end=\"6593\">Mining applications<\/li>\n<li data-section-id=\"te6ds9\" data-start=\"6594\" data-end=\"6616\">Coastal environments<\/li>\n<li data-section-id=\"1tym252\" data-start=\"6617\" data-end=\"6638\">High-humidity areas<\/li>\n<\/ul>\n<p data-start=\"6640\" data-end=\"6816\">IEC 60076-11 specifically addresses environmental, climatic, fire-behavior and enclosure-related considerations for dry-type transformers.<\/p>\n<hr data-start=\"6818\" data-end=\"6821\" \/>\n<h1 data-section-id=\"suceo2\" data-start=\"6823\" data-end=\"6850\">9. Optional Customization<\/h1>\n<p data-start=\"6852\" data-end=\"6950\">The <strong data-start=\"6856\" data-end=\"6887\">100kVA Dry Type Transformer<\/strong> can be customized according to EPC and project specifications.<\/p>\n<h3 data-section-id=\"159mu5x\" data-start=\"6952\" data-end=\"6980\">Electrical Customization<\/h3>\n<ul data-start=\"6982\" data-end=\"7056\">\n<li data-section-id=\"1o2lj7\" data-start=\"6982\" data-end=\"6987\">6kV<\/li>\n<li data-section-id=\"15g2c9q\" data-start=\"6988\" data-end=\"6995\">6.3kV<\/li>\n<li data-section-id=\"15g2gkb\" data-start=\"6996\" data-end=\"7003\">6.6kV<\/li>\n<li data-section-id=\"1j29sus\" data-start=\"7004\" data-end=\"7010\">10kV<\/li>\n<li data-section-id=\"dm3ryn\" data-start=\"7011\" data-end=\"7019\">10.5kV<\/li>\n<li data-section-id=\"1j29tlh\" data-start=\"7020\" data-end=\"7026\">11kV<\/li>\n<li data-section-id=\"do3m4h\" data-start=\"7027\" data-end=\"7035\">13.8kV<\/li>\n<li data-section-id=\"1j2c27r\" data-start=\"7036\" data-end=\"7042\">20kV<\/li>\n<li data-section-id=\"1j2bxdh\" data-start=\"7043\" data-end=\"7049\">22kV<\/li>\n<li data-section-id=\"1j2b87p\" data-start=\"7050\" data-end=\"7056\">33kV<\/li>\n<\/ul>\n<p data-start=\"7058\" data-end=\"7069\">LV options:<\/p>\n<ul data-start=\"7071\" data-end=\"7119\">\n<li data-section-id=\"1j2b4f9\" data-start=\"7071\" data-end=\"7077\">380V<\/li>\n<li data-section-id=\"1j2dkqy\" data-start=\"7078\" data-end=\"7084\">400V<\/li>\n<li data-section-id=\"1j2dmzy\" data-start=\"7085\" data-end=\"7091\">415V<\/li>\n<li data-section-id=\"1j2dhe6\" data-start=\"7092\" data-end=\"7098\">440V<\/li>\n<li data-section-id=\"1j2dj2k\" data-start=\"7099\" data-end=\"7105\">460V<\/li>\n<li data-section-id=\"1j2de0y\" data-start=\"7106\" data-end=\"7112\">480V<\/li>\n<li data-section-id=\"1j2ezup\" data-start=\"7113\" data-end=\"7119\">690V<\/li>\n<\/ul>\n<h3 data-section-id=\"e7x3hu\" data-start=\"7121\" data-end=\"7138\">Other Options<\/h3>\n<ul data-start=\"7140\" data-end=\"7442\">\n<li data-section-id=\"1cfgw9z\" data-start=\"7140\" data-end=\"7156\">Copper winding<\/li>\n<li data-section-id=\"f20kae\" data-start=\"7157\" data-end=\"7175\">Aluminum winding<\/li>\n<li data-section-id=\"16wxz7f\" data-start=\"7176\" data-end=\"7183\">Dyn11<\/li>\n<li data-section-id=\"1j48nau\" data-start=\"7184\" data-end=\"7190\">Yyn0<\/li>\n<li data-section-id=\"11p0q1m\" data-start=\"7191\" data-end=\"7215\">Dual secondary winding<\/li>\n<li data-section-id=\"17ged39\" data-start=\"7216\" data-end=\"7235\">\u00b12 \u00d7 2.5% tapping<\/li>\n<li data-section-id=\"1k7yzto\" data-start=\"7236\" data-end=\"7249\">\u00b15% tapping<\/li>\n<li data-section-id=\"vcsb34\" data-start=\"7250\" data-end=\"7267\">AN \/ AF cooling<\/li>\n<li data-section-id=\"110ureo\" data-start=\"7268\" data-end=\"7288\">IP-rated enclosure<\/li>\n<li data-section-id=\"1t5f7p4\" data-start=\"7289\" data-end=\"7313\">Temperature controller<\/li>\n<li data-section-id=\"175m8f1\" data-start=\"7314\" data-end=\"7321\">PT100<\/li>\n<li data-section-id=\"2vlhr1\" data-start=\"7322\" data-end=\"7338\">RS485 \/ Modbus<\/li>\n<li data-section-id=\"11458zh\" data-start=\"7339\" data-end=\"7357\">Surge protection<\/li>\n<li data-section-id=\"1fxmvi3\" data-start=\"7358\" data-end=\"7384\">Anti-condensation heater<\/li>\n<li data-section-id=\"1vj4khd\" data-start=\"7385\" data-end=\"7402\">Outdoor housing<\/li>\n<li data-section-id=\"w2ljwx\" data-start=\"7403\" data-end=\"7419\">Seismic design<\/li>\n<li data-section-id=\"1hnptgp\" data-start=\"7420\" data-end=\"7442\">High-altitude design<\/li>\n<\/ul>\n<hr data-start=\"7444\" data-end=\"7447\" \/>\n<h1 data-section-id=\"f82kkg\" data-start=\"7449\" data-end=\"7467\">10. Applications<\/h1>\n<div class=\"no-scrollbar flex min-h-36 flex-nowrap gap-0.5 overflow-auto sm:gap-1 sm:overflow-hidden xl:min-h-44 mt-1 mb-5 not-first:mt-4\">\n<div class=\"border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)\/3)] rounded-s-xl\">\n<div class=\"group\/search-image @container\/search-image relative rounded-[inherit] h-full w-full\">\n<div><img loading=\"lazy\" decoding=\"async\" class=\"bg-token-main-surface-tertiary m-0 h-full w-full object-cover alignnone\" src=\"https:\/\/images.openai.com\/static-rsc-4\/-A2f9SrmnEj2hHLRirnuJkcQCj7_DT6S5BLqKckOhNDf4xNDLhjYDavv4LgnDb7QJL5R_slUx8zVTGCa-gEOV7N4u3Tznq-ORMhSlaha7jBSaMeNPX71e00duOjNNVWw6kf14ZXo9egG0DrkGSu_pRjRzzcfqs5w8ft_lVxtGQk?purpose=inline\" alt=\"100kVA Dry Type Transformer\" width=\"452\" height=\"452\" \/><\/div>\n<\/div>\n<\/div>\n<div class=\"border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)\/3)]\"><\/div>\n<div class=\"border-token-border-default relative w-32 shrink-0 overflow-hidden rounded-xl border-[0.5px] md:shrink max-h-64 sm:w-[calc((100%-0.5rem)\/3)] rounded-e-xl\">\n<div class=\"group\/search-image @container\/search-image relative rounded-[inherit] h-full w-full\">\n<div class=\"pointer-events-none absolute inset-x-2 bottom-2 z-10 flex max-w-[calc(100%-1rem)] flex-wrap items-end justify-end gap-1.5\">\n<div class=\"shrink-0\">\n<div class=\"flex items-center gap-1 rounded-full px-2 py-1.5 text-white backdrop-blur-md backdrop-brightness-75\">The 100kVA dry-type transformer is suitable for:<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<h3 data-section-id=\"fdrcf6\" data-start=\"7561\" data-end=\"7586\">Industrial Facilities<\/h3>\n<p data-start=\"7587\" data-end=\"7663\">Factories, workshops, manufacturing plants and machinery power distribution.<\/p>\n<h3 data-section-id=\"1tftqe7\" data-start=\"7665\" data-end=\"7689\">Commercial Buildings<\/h3>\n<p data-start=\"7690\" data-end=\"7758\">Shopping centers, office buildings, hotels and commercial complexes.<\/p>\n<h3 data-section-id=\"1uw95y9\" data-start=\"7760\" data-end=\"7773\">Hospitals<\/h3>\n<p data-start=\"7774\" data-end=\"7868\">Suitable for locations where fire safety and reliable indoor power distribution are important.<\/p>\n<h3 data-section-id=\"1vyr6um\" data-start=\"7870\" data-end=\"7886\">Data Centers<\/h3>\n<p data-start=\"7887\" data-end=\"7968\">Can be integrated into low-voltage and medium-voltage power distribution systems.<\/p>\n<h3 data-section-id=\"4t08rp\" data-start=\"7970\" data-end=\"7990\">Renewable Energy<\/h3>\n<p data-start=\"7991\" data-end=\"8085\">Suitable for solar PV systems, energy storage systems and other renewable-energy applications.<\/p>\n<h3 data-section-id=\"14xe03l\" data-start=\"8087\" data-end=\"8105\">Infrastructure<\/h3>\n<p data-start=\"8106\" data-end=\"8170\">Airports, railway systems, tunnels, ports and public facilities.<\/p>\n<h3 data-section-id=\"kxw3f0\" data-start=\"8172\" data-end=\"8182\">Mining<\/h3>\n<p data-start=\"8183\" data-end=\"8271\">Special configurations can be designed for demanding industrial and mining environments.<\/p>\n<p data-start=\"8273\" data-end=\"8489\">Dry-type transformers are widely used in buildings, industrial plants, hospitals, airports and other applications where oil-free and fire-safe power distribution is advantageous.<\/p>\n<hr data-start=\"8491\" data-end=\"8494\" \/>\n<h1 data-section-id=\"rca6g9\" data-start=\"8496\" data-end=\"8522\">11. Manufacturer Testing<\/h1>\n<p data-start=\"8524\" data-end=\"8600\">Each transformer should undergo appropriate factory testing before shipment.<\/p>\n<h3 data-section-id=\"1u0irel\" data-start=\"8602\" data-end=\"8619\">Routine Tests<\/h3>\n<ul data-start=\"8621\" data-end=\"8922\">\n<li data-section-id=\"13jcszt\" data-start=\"8621\" data-end=\"8646\">Winding resistance test<\/li>\n<li data-section-id=\"gu8nj1\" data-start=\"8647\" data-end=\"8667\">Voltage ratio test<\/li>\n<li data-section-id=\"j6f7jj\" data-start=\"8668\" data-end=\"8708\">Vector group \/ phase displacement test<\/li>\n<li data-section-id=\"17ijv4b\" data-start=\"8709\" data-end=\"8735\">No-load loss measurement<\/li>\n<li data-section-id=\"12gcuxt\" data-start=\"8736\" data-end=\"8765\">No-load current measurement<\/li>\n<li data-section-id=\"143c3f6\" data-start=\"8766\" data-end=\"8803\">Short-circuit impedance measurement<\/li>\n<li data-section-id=\"sxvj7r\" data-start=\"8804\" data-end=\"8827\">Load loss measurement<\/li>\n<li data-section-id=\"twboyf\" data-start=\"8828\" data-end=\"8860\">Applied voltage withstand test<\/li>\n<li data-section-id=\"1li08sm\" data-start=\"8861\" data-end=\"8893\">Induced voltage withstand test<\/li>\n<li data-section-id=\"19g9fot\" data-start=\"8894\" data-end=\"8922\">Insulation resistance test<\/li>\n<\/ul>\n<h3 data-section-id=\"43tbbu\" data-start=\"8924\" data-end=\"8944\">Additional Tests<\/h3>\n<p data-start=\"8946\" data-end=\"8980\">Depending on project requirements:<\/p>\n<ul data-start=\"8982\" data-end=\"9169\">\n<li data-section-id=\"ev3p6x\" data-start=\"8982\" data-end=\"9006\">Partial discharge test<\/li>\n<li data-section-id=\"2l0vv6\" data-start=\"9007\" data-end=\"9030\">Temperature-rise test<\/li>\n<li data-section-id=\"vk13p\" data-start=\"9031\" data-end=\"9055\">Lightning impulse test<\/li>\n<li data-section-id=\"1jgoyow\" data-start=\"9056\" data-end=\"9068\">Noise test<\/li>\n<li data-section-id=\"lm67le\" data-start=\"9069\" data-end=\"9089\">Short-circuit test<\/li>\n<li data-section-id=\"eunq4q\" data-start=\"9090\" data-end=\"9110\">Fire behavior test<\/li>\n<li data-section-id=\"1psmb3b\" data-start=\"9111\" data-end=\"9138\">Enclosure protection test<\/li>\n<li data-section-id=\"1is0wem\" data-start=\"9139\" data-end=\"9169\">Climatic\/environmental tests<\/li>\n<\/ul>\n<p data-start=\"9171\" data-end=\"9287\">For EPC projects, the manufacturer can provide a <strong data-start=\"9220\" data-end=\"9249\">Factory Test Report (FAT)<\/strong> and supporting quality documentation.<\/p>\n<hr data-start=\"9289\" data-end=\"9292\" \/>\n<h1 data-section-id=\"1hxsgrq\" data-start=\"9294\" data-end=\"9318\">12. Packing &amp; Shipping<\/h1>\n<p data-start=\"9320\" data-end=\"9401\">The transformer should be properly protected before international transportation.<\/p>\n<p data-start=\"9403\" data-end=\"9421\">Typical packaging:<\/p>\n<p data-start=\"9423\" data-end=\"9527\"><strong data-start=\"9423\" data-end=\"9527\">Transformer \u2192 Moisture Protection \u2192 Shock Protection \u2192 Wooden Case \/ Steel Frame \u2192 Container Loading<\/strong><\/p>\n<p data-start=\"9529\" data-end=\"9558\">Export packaging can include:<\/p>\n<ul data-start=\"9560\" data-end=\"9744\">\n<li data-section-id=\"zt309j\" data-start=\"9560\" data-end=\"9577\">Waterproof film<\/li>\n<li data-section-id=\"sry6wc\" data-start=\"9578\" data-end=\"9605\">Moisture-proof protection<\/li>\n<li data-section-id=\"1yplxm\" data-start=\"9606\" data-end=\"9633\">Anti-collision protection<\/li>\n<li data-section-id=\"157bwx9\" data-start=\"9634\" data-end=\"9658\">Reinforced wooden case<\/li>\n<li data-section-id=\"2wbt2u\" data-start=\"9659\" data-end=\"9671\">Steel base<\/li>\n<li data-section-id=\"1oojwgw\" data-start=\"9672\" data-end=\"9688\">Lifting points<\/li>\n<li data-section-id=\"mkzr4v\" data-start=\"9689\" data-end=\"9713\">Shock-resistant fixing<\/li>\n<li data-section-id=\"1x1jrbw\" data-start=\"9714\" data-end=\"9744\">Nameplate and shipping marks<\/li>\n<\/ul>\n<p data-start=\"9746\" data-end=\"9872\">For EPC projects, packing can be customized according to the destination country, transportation method and site requirements.<\/p>\n<hr data-start=\"9874\" data-end=\"9877\" \/>\n<h1 data-section-id=\"fajg9\" data-start=\"9879\" data-end=\"9914\">13. Recommended EPC Configuration<\/h1>\n<p data-start=\"9916\" data-end=\"10017\">For a typical overseas EPC project, I would recommend presenting the product specification like this:<\/p>\n<blockquote data-start=\"10019\" data-end=\"10255\">\n<p data-start=\"10021\" data-end=\"10255\"><strong data-start=\"10021\" data-end=\"10052\">100kVA Dry Type Transformer<\/strong><br data-start=\"10052\" data-end=\"10055\" \/><strong data-start=\"10057\" data-end=\"10090\">10kV \/ 0.4kV | 50Hz | 3 Phase<\/strong><br data-start=\"10090\" data-end=\"10093\" \/><strong data-start=\"10095\" data-end=\"10125\">Cast Resin | Dyn11 | AN\/AF<\/strong><br data-start=\"10125\" data-end=\"10128\" \/><strong data-start=\"10130\" data-end=\"10146\">IEC 60076-11<\/strong><br data-start=\"10146\" data-end=\"10149\" \/><strong data-start=\"10151\" data-end=\"10181\">Copper \/ Aluminum Windings<\/strong><br data-start=\"10181\" data-end=\"10184\" \/><strong data-start=\"10186\" data-end=\"10216\">Custom Voltage &amp; Enclosure<\/strong><br data-start=\"10216\" data-end=\"10219\" \/><strong data-start=\"10221\" data-end=\"10255\">Factory Tested Before Delivery<\/strong><\/p>\n<\/blockquote>\n<p data-start=\"10257\" data-end=\"10505\">This is more suitable for an international product page than simply listing <strong data-start=\"10333\" data-end=\"10366\">\u201c100kVA Dry Type Transformer\u201d<\/strong>, because EPC buyers usually need to quickly confirm <strong data-start=\"10419\" data-end=\"10504\">capacity + voltage + standard + cooling + vector group + customization capability<\/strong>.<\/p>\n<h3 data-section-id=\"ziade7\" data-start=\"10507\" data-end=\"10545\">Suggested product-page positioning<\/h3>\n<p data-start=\"10547\" data-end=\"10609\"><strong data-start=\"10547\" data-end=\"10609\">100kVA Dry Type Transformer | 10kV to 0.4kV | IEC 60076-11<\/strong><\/p>\n<p data-start=\"10611\" data-end=\"10649\"><strong data-start=\"10611\" data-end=\"10649\">Safe. Oil-Free. Custom-Engineered.<\/strong><\/p>\n<p data-start=\"10651\" data-end=\"10832\">Designed for industrial, commercial, infrastructure and renewable-energy power distribution projects, with customized voltage, insulation, enclosure, cooling and protection options.<\/p>\n","protected":false},"excerpt":{"rendered":"<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"97\" data-end=\"379\">The <strong data-start=\"101\" data-end=\"132\">100kVA Dry Type Transformer<\/strong> is a three-phase, oil-free transformer designed for safe and reliable electrical power distribution. It uses air as the cooling medium and can be supplied in <strong data-start=\"291\" data-end=\"344\">cast resin, VPI, or other dry-type configurations<\/strong> according to project requirements.<\/p>\n<p data-start=\"381\" data-end=\"604\">A typical configuration is <strong data-start=\"408\" data-end=\"445\">10kV \/ 0.4kV, 100kVA, 50Hz, Dyn11<\/strong>, although the primary and secondary voltages, vector group, impedance, enclosure and other parameters can be customized.<\/p>\n<p data-start=\"606\" data-end=\"756\">The transformer complies with <strong data-start=\"636\" data-end=\"652\">IEC 60076-11<\/strong>, the international standard covering dry-type power transformers.<\/p>","protected":false},"featured_media":2033,"template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[],"product_cat":[75],"product_tag":[],"class_list":["post-1856","product","type-product","status-publish","has-post-thumbnail","product_cat-dry-type-transformer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product\/1856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/media\/2033"}],"wp:attachment":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/media?parent=1856"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1856"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1856"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}