{"id":2050,"date":"2026-09-16T14:42:44","date_gmt":"2026-09-16T06:42:44","guid":{"rendered":"https:\/\/www.zishengelectric.com\/?post_type=product&#038;p=2050"},"modified":"2026-09-16T14:42:44","modified_gmt":"2026-09-16T06:42:44","slug":"2000kva-oil-immersed-transformer","status":"publish","type":"product","link":"https:\/\/www.zishengelectric.com\/ar\/product\/2000kva-oil-immersed-transformer","title":{"rendered":"2000kVA Oil Immersed Transformer"},"content":{"rendered":"<div class=\"qMYqUG_convSearchResultHighlightRoot\">\n<div class=\"\" data-turn-id-container=\"request-WEB:bb45e8de-04b7-4cd4-9fb8-a5f35d73c612-22\" data-is-intersecting=\"true\">\n<section class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [&amp;:has([data-writing-block])&gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:bb45e8de-04b7-4cd4-9fb8-a5f35d73c612-22\" data-turn-id-container=\"request-WEB:bb45e8de-04b7-4cd4-9fb8-a5f35d73c612-22\" data-testid=\"conversation-turn-44\" data-turn=\"assistant\">\n<div class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\">\n<div class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden @[53.5rem]\/main:[--thread-content-max-width:48rem] relative flex w-full min-w-0 flex-col agent-turn\" data-conversation-screenshot-content=\"\">\n<div class=\"flex max-w-full flex-col gap-4 grow\">\n<div class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+&amp;]:mt-1\" dir=\"auto\" tabindex=\"0\" data-message-author-role=\"assistant\" data-message-id=\"9d7bd6c3-6746-5f3f-98f3-2cb5bdb87ef3\" data-turn-start-message=\"true\" data-message-model-slug=\"gpt-5.6-sol-wm\">\n<div class=\"flex w-full flex-col gap-1 empty:hidden\">\n<div class=\"fbskMG_root LR5Y_W_content markdown prose dark:prose-invert wrap-break-word w-full dark markdown-new-styling\">\n<p class=\"PDq2pG_selectionAnchorContainer\" dir=\"auto\" data-start=\"57\" data-end=\"384\">The 2000kVA oil-immersed transformer is a high-capacity, three-phase distribution transformer designed to convert medium-voltage electricity into a stable low-voltage supply. It is widely used in utility networks, industrial plants, mining facilities, renewable energy projects, commercial complexes and infrastructure systems.<\/p>\n<p dir=\"auto\" data-start=\"386\" data-end=\"694\">The transformer combines a high-permeability silicon-steel core, copper or aluminum windings, transformer-grade insulating oil and a durable sealed tank. Voltage ratio, vector group, impedance, cooling, efficiency, accessories and environmental protection can be customized according to project requirements.<\/p>\n<h2 dir=\"auto\" data-section-id=\"usl5df\" data-start=\"696\" data-end=\"728\">Main Technical Specifications<\/h2>\n<div class=\"group TyagGW_tableContainer TyagGW_tableContainerWithTableOfContents\" dir=\"auto\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" dir=\"auto\" data-start=\"730\" data-end=\"1998\">\n<thead data-start=\"730\" data-end=\"778\">\n<tr data-start=\"730\" data-end=\"778\">\n<th class=\"last:pe-10\" data-start=\"730\" data-end=\"742\" data-col-size=\"sm\">Parameter<\/th>\n<th class=\"last:pe-10\" data-start=\"742\" data-end=\"778\" data-col-size=\"md\">Standard Configuration \/ Options<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"789\" data-end=\"1998\">\n<tr data-start=\"789\" data-end=\"824\">\n<td data-start=\"789\" data-end=\"806\" data-col-size=\"sm\">Rated Capacity<\/td>\n<td data-col-size=\"md\" data-start=\"806\" data-end=\"824\">2000kVA \/ 2MVA<\/td>\n<\/tr>\n<tr data-start=\"825\" data-end=\"897\">\n<td data-start=\"825\" data-end=\"844\" data-col-size=\"sm\">Transformer Type<\/td>\n<td data-col-size=\"md\" data-start=\"844\" data-end=\"897\">Three-phase oil-immersed distribution transformer<\/td>\n<\/tr>\n<tr data-start=\"898\" data-end=\"942\">\n<td data-start=\"898\" data-end=\"916\" data-col-size=\"sm\">Primary Voltage<\/td>\n<td data-col-size=\"md\" data-start=\"916\" data-end=\"942\">6kV\u201335kV or customized<\/td>\n<\/tr>\n<tr data-start=\"943\" data-end=\"1009\">\n<td data-start=\"943\" data-end=\"963\" data-col-size=\"sm\">Secondary Voltage<\/td>\n<td data-col-size=\"md\" data-start=\"963\" data-end=\"1009\">400V, 415V, 440V, 480V, 690V or customized<\/td>\n<\/tr>\n<tr data-start=\"1010\" data-end=\"1044\">\n<td data-start=\"1010\" data-end=\"1028\" data-col-size=\"sm\">Rated Frequency<\/td>\n<td data-col-size=\"md\" data-start=\"1028\" data-end=\"1044\">50Hz or 60Hz<\/td>\n<\/tr>\n<tr data-start=\"1045\" data-end=\"1085\">\n<td data-start=\"1045\" data-end=\"1062\" data-col-size=\"sm\">Cooling Method<\/td>\n<td data-col-size=\"md\" data-start=\"1062\" data-end=\"1085\">ONAN; ONAF optional<\/td>\n<\/tr>\n<tr data-start=\"1086\" data-end=\"1127\">\n<td data-start=\"1086\" data-end=\"1105\" data-col-size=\"sm\">Winding Material<\/td>\n<td data-col-size=\"md\" data-start=\"1105\" data-end=\"1127\">Copper or aluminum<\/td>\n<\/tr>\n<tr data-start=\"1128\" data-end=\"1184\">\n<td data-start=\"1128\" data-end=\"1143\" data-col-size=\"sm\">Vector Group<\/td>\n<td data-col-size=\"md\" data-start=\"1143\" data-end=\"1184\">Dyn11, Dyn5, Yyn0, YNd1 or customized<\/td>\n<\/tr>\n<tr data-start=\"1185\" data-end=\"1234\">\n<td data-start=\"1185\" data-end=\"1199\" data-col-size=\"sm\">Tap Changer<\/td>\n<td data-col-size=\"md\" data-start=\"1199\" data-end=\"1234\">Off-circuit tap changer or OLTC<\/td>\n<\/tr>\n<tr data-start=\"1235\" data-end=\"1291\">\n<td data-start=\"1235\" data-end=\"1259\" data-col-size=\"sm\">Typical Tapping Range<\/td>\n<td data-col-size=\"md\" data-start=\"1259\" data-end=\"1291\">\u00b12 \u00d7 2.5%, \u00b15% or customized<\/td>\n<\/tr>\n<tr data-start=\"1292\" data-end=\"1381\">\n<td data-start=\"1292\" data-end=\"1318\" data-col-size=\"sm\">Short-Circuit Impedance<\/td>\n<td data-col-size=\"md\" data-start=\"1318\" data-end=\"1381\">Typically 6%; customizable according to system requirements<\/td>\n<\/tr>\n<tr data-start=\"1382\" data-end=\"1442\">\n<td data-start=\"1382\" data-end=\"1398\" data-col-size=\"sm\">Core Material<\/td>\n<td data-col-size=\"md\" data-start=\"1398\" data-end=\"1442\">Cold-rolled grain-oriented silicon steel<\/td>\n<\/tr>\n<tr data-start=\"1443\" data-end=\"1511\">\n<td data-start=\"1443\" data-end=\"1462\" data-col-size=\"sm\">Insulating Fluid<\/td>\n<td data-col-size=\"md\" data-start=\"1462\" data-end=\"1511\">Mineral oil, natural ester or synthetic ester<\/td>\n<\/tr>\n<tr data-start=\"1512\" data-end=\"1588\">\n<td data-start=\"1512\" data-end=\"1529\" data-col-size=\"sm\">Tank Structure<\/td>\n<td data-col-size=\"md\" data-start=\"1529\" data-end=\"1588\">Hermetically sealed corrugated tank or conservator type<\/td>\n<\/tr>\n<tr data-start=\"1589\" data-end=\"1625\">\n<td data-start=\"1589\" data-end=\"1604\" data-col-size=\"sm\">Installation<\/td>\n<td data-col-size=\"md\" data-start=\"1604\" data-end=\"1625\">Indoor or outdoor<\/td>\n<\/tr>\n<tr data-start=\"1626\" data-end=\"1694\">\n<td data-start=\"1626\" data-end=\"1646\" data-col-size=\"sm\">Standard Altitude<\/td>\n<td data-col-size=\"md\" data-start=\"1646\" data-end=\"1694\">Up to 1,000m; high-altitude design available<\/td>\n<\/tr>\n<tr data-start=\"1695\" data-end=\"1771\">\n<td data-start=\"1695\" data-end=\"1717\" data-col-size=\"sm\">Ambient Temperature<\/td>\n<td data-col-size=\"md\" data-start=\"1717\" data-end=\"1771\">Typically \u221225\u00b0C to +40\u00b0C; special design available<\/td>\n<\/tr>\n<tr data-start=\"1772\" data-end=\"1824\">\n<td data-start=\"1772\" data-end=\"1795\" data-col-size=\"sm\">Corrosion Protection<\/td>\n<td data-col-size=\"md\" data-start=\"1795\" data-end=\"1824\">C3, C4 or C5 paint system<\/td>\n<\/tr>\n<tr data-start=\"1825\" data-end=\"1910\">\n<td data-start=\"1825\" data-end=\"1848\" data-col-size=\"sm\">Applicable Standards<\/td>\n<td data-col-size=\"md\" data-start=\"1848\" data-end=\"1910\">IEC 60076, IEEE C57, ANSI, GB or project-specific standard<\/td>\n<\/tr>\n<tr data-start=\"1911\" data-end=\"1998\">\n<td data-start=\"1911\" data-end=\"1935\" data-col-size=\"sm\">Expected Service Life<\/td>\n<td data-col-size=\"md\" data-start=\"1935\" data-end=\"1998\">Approximately 25\u201330 years under proper operating conditions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 dir=\"auto\" data-section-id=\"19j9ske\" data-start=\"2000\" data-end=\"2033\">Typical Voltage Configurations<\/h2>\n<p dir=\"auto\" data-start=\"2035\" data-end=\"2068\">Available voltage ratios include:<\/p>\n<ul data-start=\"2070\" data-end=\"2237\">\n<li data-section-id=\"5d1qwr\" data-start=\"2070\" data-end=\"2081\">6kV\/0.4kV<\/li>\n<li data-section-id=\"y93qgc\" data-start=\"2082\" data-end=\"2094\">10kV\/0.4kV<\/li>\n<li data-section-id=\"1tvwljd\" data-start=\"2095\" data-end=\"2109\">11kV\/0.415kV<\/li>\n<li data-section-id=\"1tvxwst\" data-start=\"2110\" data-end=\"2124\">11kV\/0.433kV<\/li>\n<li data-section-id=\"1tqimo1\" data-start=\"2125\" data-end=\"2140\">13.8kV\/0.48kV<\/li>\n<li data-section-id=\"tifikv\" data-start=\"2141\" data-end=\"2153\">20kV\/0.4kV<\/li>\n<li data-section-id=\"ku6zqh\" data-start=\"2154\" data-end=\"2168\">22kV\/0.415kV<\/li>\n<li data-section-id=\"yub2o9\" data-start=\"2169\" data-end=\"2183\">33kV\/0.415kV<\/li>\n<li data-section-id=\"1n672ol\" data-start=\"2184\" data-end=\"2197\">33kV\/0.48kV<\/li>\n<li data-section-id=\"y8cr6t\" data-start=\"2198\" data-end=\"2237\">Other customized voltage combinations<\/li>\n<\/ul>\n<h2 dir=\"auto\" data-section-id=\"1af9f4g\" data-start=\"2239\" data-end=\"2263\">Typical Rated Current<\/h2>\n<p dir=\"auto\" data-start=\"2265\" data-end=\"2321\">The rated current depends on the selected voltage ratio.<\/p>\n<div class=\"group TyagGW_tableContainer TyagGW_tableContainerWithTableOfContents\" dir=\"auto\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" dir=\"auto\" data-start=\"2323\" data-end=\"2623\">\n<thead data-start=\"2323\" data-end=\"2385\">\n<tr data-start=\"2323\" data-end=\"2385\">\n<th class=\"last:pe-10\" data-start=\"2323\" data-end=\"2338\" data-col-size=\"sm\">Voltage Side<\/th>\n<th class=\"last:pe-10\" data-start=\"2338\" data-end=\"2356\" data-col-size=\"sm\">Example Voltage<\/th>\n<th class=\"last:pe-10\" data-start=\"2356\" data-end=\"2385\" data-col-size=\"sm\">Approximate Rated Current<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2402\" data-end=\"2623\">\n<tr data-start=\"2402\" data-end=\"2434\">\n<td data-start=\"2402\" data-end=\"2417\" data-col-size=\"sm\">High Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"2417\" data-end=\"2424\">10kV<\/td>\n<td data-col-size=\"sm\" data-start=\"2424\" data-end=\"2434\">115.5A<\/td>\n<\/tr>\n<tr data-start=\"2435\" data-end=\"2465\">\n<td data-start=\"2435\" data-end=\"2450\" data-col-size=\"sm\">High Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"2450\" data-end=\"2457\">11kV<\/td>\n<td data-col-size=\"sm\" data-start=\"2457\" data-end=\"2465\">105A<\/td>\n<\/tr>\n<tr data-start=\"2466\" data-end=\"2497\">\n<td data-start=\"2466\" data-end=\"2481\" data-col-size=\"sm\">High Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"2481\" data-end=\"2488\">20kV<\/td>\n<td data-col-size=\"sm\" data-start=\"2488\" data-end=\"2497\">57.7A<\/td>\n<\/tr>\n<tr data-start=\"2498\" data-end=\"2527\">\n<td data-start=\"2498\" data-end=\"2513\" data-col-size=\"sm\">High Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"2513\" data-end=\"2520\">33kV<\/td>\n<td data-col-size=\"sm\" data-start=\"2520\" data-end=\"2527\">35A<\/td>\n<\/tr>\n<tr data-start=\"2528\" data-end=\"2559\">\n<td data-start=\"2528\" data-end=\"2542\" data-col-size=\"sm\">Low Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"2542\" data-end=\"2549\">400V<\/td>\n<td data-col-size=\"sm\" data-start=\"2549\" data-end=\"2559\">2,887A<\/td>\n<\/tr>\n<tr data-start=\"2560\" data-end=\"2591\">\n<td data-start=\"2560\" data-end=\"2574\" data-col-size=\"sm\">Low Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"2574\" data-end=\"2581\">415V<\/td>\n<td data-col-size=\"sm\" data-start=\"2581\" data-end=\"2591\">2,783A<\/td>\n<\/tr>\n<tr data-start=\"2592\" data-end=\"2623\">\n<td data-start=\"2592\" data-end=\"2606\" data-col-size=\"sm\">Low Voltage<\/td>\n<td data-col-size=\"sm\" data-start=\"2606\" data-end=\"2613\">480V<\/td>\n<td data-col-size=\"sm\" data-start=\"2613\" data-end=\"2623\">2,406A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p dir=\"auto\" data-start=\"2625\" data-end=\"2735\"><em data-start=\"2625\" data-end=\"2735\">Values are calculated for a three-phase 2000kVA transformer and must be confirmed during engineering design.<\/em><\/p>\n<h2 dir=\"auto\" data-section-id=\"1oy5bwe\" data-start=\"2737\" data-end=\"2760\">Key Product Features<\/h2>\n<h3 dir=\"auto\" data-section-id=\"l5t5pz\" data-start=\"2762\" data-end=\"2795\">High-Efficiency Magnetic Core<\/h3>\n<p dir=\"auto\" data-start=\"2797\" data-end=\"2999\">The transformer core is manufactured from high-permeability, cold-rolled grain-oriented silicon steel. Step-lap construction helps reduce no-load loss, excitation current, vibration and operating noise.<\/p>\n<h3 dir=\"auto\" data-section-id=\"qvz0eu\" data-start=\"3001\" data-end=\"3037\">Mechanically Reinforced Windings<\/h3>\n<p dir=\"auto\" data-start=\"3039\" data-end=\"3239\">Copper or aluminum windings are engineered to withstand thermal stress, load fluctuations and short-circuit forces. Oil ducts are arranged to improve heat dissipation throughout the winding structure.<\/p>\n<h3 dir=\"auto\" data-section-id=\"1ldex0b\" data-start=\"3241\" data-end=\"3265\">Reliable Oil Cooling<\/h3>\n<p dir=\"auto\" data-start=\"3267\" data-end=\"3508\">The insulating oil provides both electrical insulation and heat transfer. ONAN cooling enables reliable operation without external cooling equipment. ONAF cooling with fans is available for increased loading or high-temperature environments.<\/p>\n<h3 dir=\"auto\" data-section-id=\"i5pp0x\" data-start=\"3510\" data-end=\"3538\">Sealed Tank Construction<\/h3>\n<p dir=\"auto\" data-start=\"3540\" data-end=\"3721\">A hermetically sealed corrugated tank prevents direct contact between insulating oil and outside air. This helps reduce moisture ingress, oil oxidation and maintenance requirements.<\/p>\n<p dir=\"auto\" data-start=\"3723\" data-end=\"3790\">A conservator-type tank with a Buchholz relay can also be supplied.<\/p>\n<h3 dir=\"auto\" data-section-id=\"iu9yvd\" data-start=\"3792\" data-end=\"3814\">Low-Loss Operation<\/h3>\n<p dir=\"auto\" data-start=\"3816\" data-end=\"3879\">The electrical and magnetic design can be optimized to provide:<\/p>\n<ul data-start=\"3881\" data-end=\"4068\">\n<li data-section-id=\"1mc7dlh\" data-start=\"3881\" data-end=\"3899\">Low no-load loss<\/li>\n<li data-section-id=\"qqhqvb\" data-start=\"3900\" data-end=\"3922\">Controlled load loss<\/li>\n<li data-section-id=\"1xn97q0\" data-start=\"3923\" data-end=\"3946\">Stable output voltage<\/li>\n<li data-section-id=\"15u0la5\" data-start=\"3947\" data-end=\"3978\">Reduced operating temperature<\/li>\n<li data-section-id=\"1mhg0uz\" data-start=\"3979\" data-end=\"4004\">Low noise and vibration<\/li>\n<li data-section-id=\"1bn4qno\" data-start=\"4005\" data-end=\"4038\">Strong short-circuit resistance<\/li>\n<li data-section-id=\"1lnb78i\" data-start=\"4039\" data-end=\"4068\">Lower lifetime energy costs<\/li>\n<\/ul>\n<h3 dir=\"auto\" data-section-id=\"6ekxgc\" data-start=\"4070\" data-end=\"4100\">Environmental Adaptability<\/h3>\n<p dir=\"auto\" data-start=\"4102\" data-end=\"4136\">Special designs are available for:<\/p>\n<ul data-start=\"4138\" data-end=\"4370\">\n<li data-section-id=\"gge42p\" data-start=\"4138\" data-end=\"4165\">High ambient temperatures<\/li>\n<li data-section-id=\"pabqfp\" data-start=\"4166\" data-end=\"4191\">High-altitude locations<\/li>\n<li data-section-id=\"m7p2ob\" data-start=\"4192\" data-end=\"4227\">Coastal and salt-fog environments<\/li>\n<li data-section-id=\"5umxkp\" data-start=\"4228\" data-end=\"4252\">Desert and dusty areas<\/li>\n<li data-section-id=\"19mr1r\" data-start=\"4253\" data-end=\"4290\">Tropical and high-humidity climates<\/li>\n<li data-section-id=\"id3ega\" data-start=\"4291\" data-end=\"4331\">Chemically aggressive industrial sites<\/li>\n<li data-section-id=\"1fm565o\" data-start=\"4332\" data-end=\"4370\">Mining and renewable energy projects<\/li>\n<\/ul>\n<h2 dir=\"auto\" data-section-id=\"9xu6fm\" data-start=\"4372\" data-end=\"4390\">Main Components<\/h2>\n<p dir=\"auto\" data-start=\"4392\" data-end=\"4444\">A typical 2000kVA oil-immersed transformer includes:<\/p>\n<ul data-start=\"4446\" data-end=\"4891\">\n<li data-section-id=\"14dxo7h\" data-start=\"4446\" data-end=\"4461\">Magnetic core<\/li>\n<li data-section-id=\"n71scd\" data-start=\"4462\" data-end=\"4484\">High-voltage winding<\/li>\n<li data-section-id=\"122z8sn\" data-start=\"4485\" data-end=\"4506\">Low-voltage winding<\/li>\n<li data-section-id=\"aws36p\" data-start=\"4507\" data-end=\"4535\">Transformer insulating oil<\/li>\n<li data-section-id=\"eiuoco\" data-start=\"4536\" data-end=\"4559\">Main transformer tank<\/li>\n<li data-section-id=\"1xnmeid\" data-start=\"4560\" data-end=\"4599\">Corrugated fins or external radiators<\/li>\n<li data-section-id=\"uzwmwm\" data-start=\"4600\" data-end=\"4623\">High-voltage bushings<\/li>\n<li data-section-id=\"l7dm30\" data-start=\"4624\" data-end=\"4646\">Low-voltage bushings<\/li>\n<li data-section-id=\"1mmt9ox\" data-start=\"4647\" data-end=\"4664\">Neutral bushing<\/li>\n<li data-section-id=\"19mk3s8\" data-start=\"4665\" data-end=\"4690\">Off-circuit tap changer<\/li>\n<li data-section-id=\"drksw9\" data-start=\"4691\" data-end=\"4715\">Pressure-relief device<\/li>\n<li data-section-id=\"wf1i50\" data-start=\"4716\" data-end=\"4755\">Oil-level indicator, where applicable<\/li>\n<li data-section-id=\"137b499\" data-start=\"4756\" data-end=\"4786\">Oil filling and drain valves<\/li>\n<li data-section-id=\"196kl11\" data-start=\"4787\" data-end=\"4807\">Earthing terminals<\/li>\n<li data-section-id=\"to590y\" data-start=\"4808\" data-end=\"4822\">Lifting lugs<\/li>\n<li data-section-id=\"502xbh\" data-start=\"4823\" data-end=\"4837\">Jacking pads<\/li>\n<li data-section-id=\"4lrylo\" data-start=\"4838\" data-end=\"4860\">Rollers or skid base<\/li>\n<li data-section-id=\"1ly5lot\" data-start=\"4861\" data-end=\"4891\">Stainless-steel rating plate<\/li>\n<\/ul>\n<h2 dir=\"auto\" data-section-id=\"uoahhp\" data-start=\"4893\" data-end=\"4916\">Optional Accessories<\/h2>\n<p dir=\"auto\" data-start=\"4918\" data-end=\"4948\">Available accessories include:<\/p>\n<ul data-start=\"4950\" data-end=\"5412\">\n<li data-section-id=\"1embb6u\" data-start=\"4950\" data-end=\"4966\">Buchholz relay<\/li>\n<li data-section-id=\"1axeqkv\" data-start=\"4967\" data-end=\"4994\">Oil temperature indicator<\/li>\n<li data-section-id=\"1i79cy9\" data-start=\"4995\" data-end=\"5026\">Winding temperature indicator<\/li>\n<li data-section-id=\"3kn7fa\" data-start=\"5027\" data-end=\"5053\">Magnetic oil-level gauge<\/li>\n<li data-section-id=\"1bq8a32\" data-start=\"5054\" data-end=\"5077\">Sudden-pressure relay<\/li>\n<li data-section-id=\"16etp39\" data-start=\"5078\" data-end=\"5101\">Pressure vacuum gauge<\/li>\n<li data-section-id=\"1umv7j1\" data-start=\"5102\" data-end=\"5116\">Cooling fans<\/li>\n<li data-section-id=\"1y617uh\" data-start=\"5117\" data-end=\"5134\">Marshalling box<\/li>\n<li data-section-id=\"g4lb61\" data-start=\"5135\" data-end=\"5157\">Current transformers<\/li>\n<li data-section-id=\"1a2dblb\" data-start=\"5158\" data-end=\"5187\">Neutral current transformer<\/li>\n<li data-section-id=\"18d2x09\" data-start=\"5188\" data-end=\"5205\">Surge arresters<\/li>\n<li data-section-id=\"e1qsxu\" data-start=\"5206\" data-end=\"5219\">Cable boxes<\/li>\n<li data-section-id=\"gsfwmr\" data-start=\"5220\" data-end=\"5238\">Plug-in bushings<\/li>\n<li data-section-id=\"4snhu2\" data-start=\"5239\" data-end=\"5270\">HV and LV terminal enclosures<\/li>\n<li data-section-id=\"cdnvnc\" data-start=\"5271\" data-end=\"5303\">Remote alarm and trip contacts<\/li>\n<li data-section-id=\"1at608f\" data-start=\"5304\" data-end=\"5342\">Online temperature-monitoring system<\/li>\n<li data-section-id=\"gjlfv1\" data-start=\"5343\" data-end=\"5385\">Digital transformer-monitoring interface<\/li>\n<li data-section-id=\"1fxmvi3\" data-start=\"5386\" data-end=\"5412\">Anti-condensation heater<\/li>\n<\/ul>\n<h2 dir=\"auto\" data-section-id=\"rnyyeg\" data-start=\"5414\" data-end=\"5438\">Customization Options<\/h2>\n<div class=\"group TyagGW_tableContainer TyagGW_tableContainerWithTableOfContents\" dir=\"auto\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" dir=\"auto\" data-start=\"5440\" data-end=\"6409\">\n<thead data-start=\"5440\" data-end=\"5468\">\n<tr data-start=\"5440\" data-end=\"5468\">\n<th class=\"last:pe-10\" data-start=\"5440\" data-end=\"5447\" data-col-size=\"sm\">Item<\/th>\n<th class=\"last:pe-10\" data-start=\"5447\" data-end=\"5468\" data-col-size=\"md\">Available Options<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"5479\" data-end=\"6409\">\n<tr data-start=\"5479\" data-end=\"5540\">\n<td data-start=\"5479\" data-end=\"5495\" data-col-size=\"sm\">Voltage Ratio<\/td>\n<td data-col-size=\"md\" data-start=\"5495\" data-end=\"5540\">Customized primary and secondary voltages<\/td>\n<\/tr>\n<tr data-start=\"5541\" data-end=\"5569\">\n<td data-start=\"5541\" data-end=\"5553\" data-col-size=\"sm\">Frequency<\/td>\n<td data-col-size=\"md\" data-start=\"5553\" data-end=\"5569\">50Hz or 60Hz<\/td>\n<\/tr>\n<tr data-start=\"5570\" data-end=\"5604\">\n<td data-start=\"5570\" data-end=\"5582\" data-col-size=\"sm\">Conductor<\/td>\n<td data-col-size=\"md\" data-start=\"5582\" data-end=\"5604\">Copper or aluminum<\/td>\n<\/tr>\n<tr data-start=\"5605\" data-end=\"5669\">\n<td data-start=\"5605\" data-end=\"5620\" data-col-size=\"sm\">Vector Group<\/td>\n<td data-col-size=\"md\" data-start=\"5620\" data-end=\"5669\">Configured according to the electrical system<\/td>\n<\/tr>\n<tr data-start=\"5670\" data-end=\"5725\">\n<td data-start=\"5670\" data-end=\"5687\" data-col-size=\"sm\">Tap Regulation<\/td>\n<td data-col-size=\"md\" data-start=\"5687\" data-end=\"5725\">Off-circuit or on-load tap changer<\/td>\n<\/tr>\n<tr data-start=\"5726\" data-end=\"5759\">\n<td data-start=\"5726\" data-end=\"5743\" data-col-size=\"sm\">Cooling Method<\/td>\n<td data-col-size=\"md\" data-start=\"5743\" data-end=\"5759\">ONAN or ONAF<\/td>\n<\/tr>\n<tr data-start=\"5760\" data-end=\"5828\">\n<td data-start=\"5760\" data-end=\"5779\" data-col-size=\"sm\">Insulating Fluid<\/td>\n<td data-col-size=\"md\" data-start=\"5779\" data-end=\"5828\">Mineral oil, natural ester or synthetic ester<\/td>\n<\/tr>\n<tr data-start=\"5829\" data-end=\"5884\">\n<td data-start=\"5829\" data-end=\"5843\" data-col-size=\"sm\">Tank Design<\/td>\n<td data-col-size=\"md\" data-start=\"5843\" data-end=\"5884\">Sealed corrugated or conservator type<\/td>\n<\/tr>\n<tr data-start=\"5885\" data-end=\"5961\">\n<td data-start=\"5885\" data-end=\"5904\" data-col-size=\"sm\">Efficiency Level<\/td>\n<td data-col-size=\"md\" data-start=\"5904\" data-end=\"5961\">According to local regulations or tender requirements<\/td>\n<\/tr>\n<tr data-start=\"5962\" data-end=\"6028\">\n<td data-start=\"5962\" data-end=\"5981\" data-col-size=\"sm\">Temperature Rise<\/td>\n<td data-col-size=\"md\" data-start=\"5981\" data-end=\"6028\">Standard or reduced temperature-rise design<\/td>\n<\/tr>\n<tr data-start=\"6029\" data-end=\"6082\">\n<td data-start=\"6029\" data-end=\"6043\" data-col-size=\"sm\">Noise Level<\/td>\n<td data-col-size=\"md\" data-start=\"6043\" data-end=\"6082\">Standard or low-noise configuration<\/td>\n<\/tr>\n<tr data-start=\"6083\" data-end=\"6135\">\n<td data-start=\"6083\" data-end=\"6106\" data-col-size=\"sm\">Corrosion Protection<\/td>\n<td data-col-size=\"md\" data-start=\"6106\" data-end=\"6135\">C3, C4 or C5 paint system<\/td>\n<\/tr>\n<tr data-start=\"6136\" data-end=\"6195\">\n<td data-start=\"6136\" data-end=\"6148\" data-col-size=\"sm\">Terminals<\/td>\n<td data-col-size=\"md\" data-start=\"6148\" data-end=\"6195\">Bushings, cable boxes or busbar connections<\/td>\n<\/tr>\n<tr data-start=\"6196\" data-end=\"6279\">\n<td data-start=\"6196\" data-end=\"6219\" data-col-size=\"sm\">Environmental Design<\/td>\n<td data-col-size=\"md\" data-start=\"6219\" data-end=\"6279\">Tropical, desert, coastal, cold-climate or high-altitude<\/td>\n<\/tr>\n<tr data-start=\"6280\" data-end=\"6343\">\n<td data-start=\"6280\" data-end=\"6293\" data-col-size=\"sm\">Monitoring<\/td>\n<td data-col-size=\"md\" data-start=\"6293\" data-end=\"6343\">Local instruments or remote digital monitoring<\/td>\n<\/tr>\n<tr data-start=\"6344\" data-end=\"6409\">\n<td data-start=\"6344\" data-end=\"6356\" data-col-size=\"sm\">Standards<\/td>\n<td data-col-size=\"md\" data-start=\"6356\" data-end=\"6409\">IEC, IEEE\/ANSI, GB or customer-specified standard<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 dir=\"auto\" data-section-id=\"2gad1q\" data-start=\"6411\" data-end=\"6435\">Manufacturing Process<\/h2>\n<ol data-start=\"6437\" data-end=\"6825\">\n<li data-section-id=\"14if30s\" data-start=\"6437\" data-end=\"6470\">Technical requirement review<\/li>\n<li data-section-id=\"14r1eg5\" data-start=\"6471\" data-end=\"6508\">Electrical and mechanical design<\/li>\n<li data-section-id=\"12e45y3\" data-start=\"6509\" data-end=\"6539\">Customer drawing approval<\/li>\n<li data-section-id=\"plb7mf\" data-start=\"6540\" data-end=\"6570\">Core cutting and stacking<\/li>\n<li data-section-id=\"vxaq6e\" data-start=\"6571\" data-end=\"6604\">HV and LV winding production<\/li>\n<li data-section-id=\"1bm7cxh\" data-start=\"6605\" data-end=\"6630\">Active-part assembly<\/li>\n<li data-section-id=\"1ti6ctx\" data-start=\"6631\" data-end=\"6674\">Vacuum drying and insulation treatment<\/li>\n<li data-section-id=\"wjqxw\" data-start=\"6675\" data-end=\"6716\">Tank fabrication and surface coating<\/li>\n<li data-section-id=\"1aqz3vy\" data-start=\"6717\" data-end=\"6740\">Vacuum oil filling<\/li>\n<li data-section-id=\"8c1042\" data-start=\"6741\" data-end=\"6780\">Electrical and mechanical testing<\/li>\n<li data-section-id=\"hhm5yv\" data-start=\"6781\" data-end=\"6825\">Final inspection, packing and shipment<\/li>\n<\/ol>\n<h2 dir=\"auto\" data-section-id=\"14376ju\" data-start=\"6827\" data-end=\"6851\">Routine Factory Tests<\/h2>\n<p dir=\"auto\" data-start=\"6853\" data-end=\"6932\">Every 2000kVA transformer undergoes routine testing before shipment, including:<\/p>\n<ul data-start=\"6934\" data-end=\"7385\">\n<li data-section-id=\"19xdwd1\" data-start=\"6934\" data-end=\"6966\">Winding resistance measurement<\/li>\n<li data-section-id=\"1ss3crw\" data-start=\"6967\" data-end=\"6994\">Voltage-ratio measurement<\/li>\n<li data-section-id=\"w11sre\" data-start=\"6995\" data-end=\"7022\">Vector-group verification<\/li>\n<li data-section-id=\"1t41k89\" data-start=\"7023\" data-end=\"7061\">No-load loss and current measurement<\/li>\n<li data-section-id=\"13rfci2\" data-start=\"7062\" data-end=\"7085\">Load-loss measurement<\/li>\n<li data-section-id=\"143c3f6\" data-start=\"7086\" data-end=\"7123\">Short-circuit impedance measurement<\/li>\n<li data-section-id=\"17noomp\" data-start=\"7124\" data-end=\"7159\">Insulation resistance measurement<\/li>\n<li data-section-id=\"twboyf\" data-start=\"7160\" data-end=\"7192\">Applied voltage withstand test<\/li>\n<li data-section-id=\"1r9exc8\" data-start=\"7193\" data-end=\"7229\">Induced overvoltage withstand test<\/li>\n<li data-section-id=\"jbjaxb\" data-start=\"7230\" data-end=\"7255\">Transformer oil testing<\/li>\n<li data-section-id=\"1p42vf1\" data-start=\"7256\" data-end=\"7285\">Tap-changer functional test<\/li>\n<li data-section-id=\"1mka9hi\" data-start=\"7286\" data-end=\"7311\">Tank leakage inspection<\/li>\n<li data-section-id=\"641ki3\" data-start=\"7312\" data-end=\"7349\">Accessory and alarm-contact testing<\/li>\n<li data-section-id=\"18cfkr8\" data-start=\"7350\" data-end=\"7385\">Visual and dimensional inspection<\/li>\n<\/ul>\n<h2 dir=\"auto\" data-section-id=\"15f7ebg\" data-start=\"7387\" data-end=\"7421\">Optional Type and Special Tests<\/h2>\n<p dir=\"auto\" data-start=\"7423\" data-end=\"7498\">The following tests can be arranged according to the project specification:<\/p>\n<ul data-start=\"7500\" data-end=\"7827\">\n<li data-section-id=\"2l0vv6\" data-start=\"7500\" data-end=\"7523\">Temperature-rise test<\/li>\n<li data-section-id=\"vk13p\" data-start=\"7524\" data-end=\"7548\">Lightning impulse test<\/li>\n<li data-section-id=\"19ryobe\" data-start=\"7549\" data-end=\"7574\">Sound-level measurement<\/li>\n<li data-section-id=\"ynljwk\" data-start=\"7575\" data-end=\"7599\">Partial-discharge test<\/li>\n<li data-section-id=\"1olusem\" data-start=\"7600\" data-end=\"7637\">Zero-sequence impedance measurement<\/li>\n<li data-section-id=\"n2bas8\" data-start=\"7638\" data-end=\"7679\">Capacitance and dissipation-factor test<\/li>\n<li data-section-id=\"153gicd\" data-start=\"7680\" data-end=\"7709\">Frequency response analysis<\/li>\n<li data-section-id=\"nvd66z\" data-start=\"7710\" data-end=\"7734\">Dissolved-gas analysis<\/li>\n<li data-section-id=\"1qcyye4\" data-start=\"7735\" data-end=\"7765\">Short-circuit withstand test<\/li>\n<li data-section-id=\"1yrgoeq\" data-start=\"7766\" data-end=\"7790\">Customer-witnessed FAT<\/li>\n<li data-section-id=\"oewvgw\" data-start=\"7791\" data-end=\"7827\">Independent third-party inspection<\/li>\n<\/ul>\n<h2 dir=\"auto\" data-section-id=\"mu966k\" data-start=\"7829\" data-end=\"7844\">Applications<\/h2>\n<p dir=\"auto\" data-start=\"7846\" data-end=\"7899\">The 2000kVA oil-immersed transformer is suitable for:<\/p>\n<ul data-start=\"7901\" data-end=\"8299\">\n<li data-section-id=\"1ei5txb\" data-start=\"7901\" data-end=\"7932\">Utility distribution networks<\/li>\n<li data-section-id=\"rzdgjh\" data-start=\"7933\" data-end=\"7955\">Industrial factories<\/li>\n<li data-section-id=\"pq5ogs\" data-start=\"7956\" data-end=\"7978\">Manufacturing plants<\/li>\n<li data-section-id=\"15mr3no\" data-start=\"7979\" data-end=\"7996\">Mining projects<\/li>\n<li data-section-id=\"ll263s\" data-start=\"7997\" data-end=\"8022\">Steel and cement plants<\/li>\n<li data-section-id=\"109rian\" data-start=\"8023\" data-end=\"8047\">Oil and gas facilities<\/li>\n<li data-section-id=\"vtwxgm\" data-start=\"8048\" data-end=\"8081\">Solar photovoltaic power plants<\/li>\n<li data-section-id=\"elqwfr\" data-start=\"8082\" data-end=\"8094\">Wind farms<\/li>\n<li data-section-id=\"fxlacl\" data-start=\"8095\" data-end=\"8127\">Battery energy-storage systems<\/li>\n<li data-section-id=\"1eyyf42\" data-start=\"8128\" data-end=\"8150\">Commercial complexes<\/li>\n<li data-section-id=\"zyv9pw\" data-start=\"8151\" data-end=\"8175\">Hospitals and airports<\/li>\n<li data-section-id=\"1ox5wdz\" data-start=\"8176\" data-end=\"8204\">Water-treatment facilities<\/li>\n<li data-section-id=\"1fhjl8g\" data-start=\"8205\" data-end=\"8219\">Data centres<\/li>\n<li data-section-id=\"eyi82v\" data-start=\"8220\" data-end=\"8246\">Municipal infrastructure<\/li>\n<li data-section-id=\"19k8p10\" data-start=\"8247\" data-end=\"8265\">Industrial parks<\/li>\n<li data-section-id=\"193f3yo\" data-start=\"8266\" data-end=\"8299\">EPC power-distribution projects<\/li>\n<\/ul>\n<h2 dir=\"auto\" data-section-id=\"n4rgbp\" data-start=\"8301\" data-end=\"8324\">Packing and Shipping<\/h2>\n<p dir=\"auto\" data-start=\"8326\" data-end=\"8545\">The transformer is secured on a reinforced steel or wooden base and protected with moisture-resistant export packaging. Bushings, radiators and vulnerable accessories may be removed and packed separately when necessary.<\/p>\n<p dir=\"auto\" data-start=\"8547\" data-end=\"8588\">Available transportation methods include:<\/p>\n<ul data-start=\"8590\" data-end=\"8747\">\n<li data-section-id=\"1r0gk3f\" data-start=\"8590\" data-end=\"8622\">Standard or open-top container<\/li>\n<li data-section-id=\"15otkbq\" data-start=\"8623\" data-end=\"8644\">Flat-rack container<\/li>\n<li data-section-id=\"qh3c7x\" data-start=\"8645\" data-end=\"8663\">Breakbulk vessel<\/li>\n<li data-section-id=\"1rgv3m6\" data-start=\"8664\" data-end=\"8685\">Road transportation<\/li>\n<li data-section-id=\"6xxunj\" data-start=\"8686\" data-end=\"8710\">Railway transportation<\/li>\n<li data-section-id=\"1mb0h4j\" data-start=\"8711\" data-end=\"8747\">Multimodal international transport<\/li>\n<\/ul>\n<p dir=\"auto\" data-start=\"8749\" data-end=\"8899\">The documentation package can include approved drawings, routine test reports, operation manuals, packing lists, quality certificates and FAT records.<\/p>\n<h2 dir=\"auto\" data-section-id=\"5swmns\" data-start=\"8901\" data-end=\"8940\">Information Required for a Quotation<\/h2>\n<p dir=\"auto\" data-start=\"8942\" data-end=\"8957\">Please provide:<\/p>\n<ul data-start=\"8959\" data-end=\"9330\">\n<li data-section-id=\"e9mg7r\" data-start=\"8959\" data-end=\"8990\">Primary and secondary voltage<\/li>\n<li data-section-id=\"1b77bik\" data-start=\"8991\" data-end=\"9002\">Frequency<\/li>\n<li data-section-id=\"1y4t33i\" data-start=\"9003\" data-end=\"9017\">Vector group<\/li>\n<li data-section-id=\"pwaj1z\" data-start=\"9018\" data-end=\"9036\">Winding material<\/li>\n<li data-section-id=\"1n3hy0t\" data-start=\"9037\" data-end=\"9057\">Required impedance<\/li>\n<li data-section-id=\"1oekm2l\" data-start=\"9058\" data-end=\"9090\">Tap range and tap-changer type<\/li>\n<li data-section-id=\"1x7dk3i\" data-start=\"9091\" data-end=\"9112\">Applicable standard<\/li>\n<li data-section-id=\"alfp50\" data-start=\"9113\" data-end=\"9136\">Installation altitude<\/li>\n<li data-section-id=\"1snvjex\" data-start=\"9137\" data-end=\"9178\">Maximum and minimum ambient temperature<\/li>\n<li data-section-id=\"18wkpkw\" data-start=\"9179\" data-end=\"9211\">Indoor or outdoor installation<\/li>\n<li data-section-id=\"x8i5of\" data-start=\"9212\" data-end=\"9240\">Cable or busbar connection<\/li>\n<li data-section-id=\"ogx5bb\" data-start=\"9241\" data-end=\"9263\">Required accessories<\/li>\n<li data-section-id=\"iljpd9\" data-start=\"9264\" data-end=\"9297\">Efficiency or loss requirements<\/li>\n<li data-section-id=\"bo6loz\" data-start=\"9298\" data-end=\"9308\">Quantity<\/li>\n<li data-section-id=\"99ys9o\" data-start=\"9309\" data-end=\"9330\">Destination country<\/li>\n<\/ul>\n<p dir=\"auto\" data-start=\"9332\" data-end=\"9493\" data-is-last-node=\"\" data-is-only-node=\"\"><em data-start=\"9332\" data-end=\"9493\" data-is-last-node=\"\">Final losses, insulation levels, dimensions, weight and accessory configuration are subject to the approved technical specification and manufacturing drawings.<\/em><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"z-0 flex min-h-[46px] justify-start\"><\/div>\n<div class=\"mt-3 w-full empty:hidden has-[&gt;_:empty]:hidden\">\n<div class=\"text-center\"><\/div>\n<\/div>\n<\/div>\n<div class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1\" data-conversation-screenshot-content=\"\">\n<div><\/div>\n<\/div>\n<\/div>\n<\/section>\n<\/div>\n<\/div>\n<div class=\"pointer-events-none -mt-px h-px translate-y-(--scroll-root-safe-area-inset-bottom)\" aria-hidden=\"true\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The 2000kVA oil-immersed transformer provides efficient and reliable power distribution for utility, industrial and renewable energy projects. It supports customized voltage ratios, copper or aluminum windings, ONAN\/ONAF cooling and IEC\/IEEE-compliant designs.<\/p>","protected":false},"featured_media":2051,"template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[],"product_cat":[71],"product_tag":[],"class_list":["post-2050","product","type-product","status-publish","has-post-thumbnail","product_cat-oil-immersed-transformer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product\/2050","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/media\/2051"}],"wp:attachment":[{"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/media?parent=2050"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_brand?post=2050"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_cat?post=2050"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ar\/wp-json\/wp\/v2\/product_tag?post=2050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}