Zisheng ELECTRIC has been specialized in manufacturing 75kVA Conventional Type Single Phase pole Mounted transformer for more than 20 years, which complies with international standards such as ANSI/IEEE C57, IEC60076 and other standards. Its main function is to convert high voltage electricity (such as 11kV, 13.8kV, etc.) into low voltage electricity (such as 120V/240V), providing stable and reliable power supply to end users. It is suitable for residential, commercial, agricultural and small industrial loads. Typical specifications include mineral oil insulation (ONAN cooling), aluminum or copper windings, primary voltages 2.4kV–34.5kV grounded wye or delta (common: 7200/12470GrdY, 7620/13200GrdY, 12470GrdY/7200, 24940GrdY/14400, 34500GrdY/19920), secondary 120/240V or 240/120V split-phase, BIL ratings 95–150kV HV / 30kV LV, impedance typically 2.0–4.0%, ±2×2.5% or 5-position tap changer, conventional or CSP (completely self-protected) configurations with internal fuses, lightning arresters, weak-link protection, pressure relief valve, oil sight gauge, and ANSI 70 gray tank finish. Efficiency typically reaches 99.17–99.19% at 50% load per DOE levels, with low sound levels and corrosion-resistant hardware for extended outdoor service.

Categoría:

Project Partners

Phone/WhatsApp: 8619131285373

Email: info@zishengtransformer.com
Factory Headquarters: No. 118, Jingyi Street, Economic Development Zone.

*
*
*

Project Stage

Submitting!
Submission successful!
Submission failed!
Incorrect email address!
Incorrect phone number!

NPC ELECTRIC has been specialized in manufacturing 75kVA Conventional Type Single Phase pole Mounted transformer for more than 20 years, which complies with international standards such as ANSI/IEEE C57, IEC60076 and other standards. Its main function is to convert high voltage electricity (such as 11kV, 13.8kV, etc.) into low voltage electricity (such as 120V/240V), providing stable and reliable power supply to end users. It is suitable for residential, commercial, agricultural and small industrial loads. Typical specifications include mineral oil insulation (ONAN cooling), aluminum or copper windings, primary voltages 2.4kV–34.5kV grounded wye or delta (common: 7200/12470GrdY, 7620/13200GrdY, 12470GrdY/7200, 24940GrdY/14400, 34500GrdY/19920), secondary 120/240V or 240/120V split-phase, BIL ratings 95–150kV HV / 30kV LV, impedance typically 2.0–4.0%, ±2×2.5% or 5-position tap changer, conventional or CSP (completely self-protected) configurations with internal fuses, lightning arresters, weak-link protection, pressure relief valve, oil sight gauge, and ANSI 70 gray tank finish. Efficiency typically reaches 99.17–99.19% at 50% load per DOE levels, with low sound levels and corrosion-resistant hardware for extended outdoor service.The 75kVA Conventional Type Single Phase Pole Mounted Transformer is a reliable oil-immersed distribution transformer designed for overhead power distribution networks. It is mainly used to step down medium-voltage electricity from utility distribution lines into low-voltage power suitable for residential, commercial, agricultural, and small industrial applications.

With a compact structure, high electrical efficiency, and excellent outdoor durability, this transformer is widely installed on utility poles in rural electrification systems, residential communities, and distribution networks where overhead power transmission is preferred.

The transformer adopts a high-quality grain-oriented silicon steel core, copper or aluminum windings, mineral oil insulation, and ONAN cooling technology to ensure stable operation, low energy loss, and long service life. It can be customized according to different grid standards, including voltage levels, insulation systems, protection configurations, and installation requirements.


Product Overview

The 75kVA Single Phase Pole Mounted Transformer converts medium voltage electricity (such as 11kV, 13.8kV, or other distribution voltages) into low voltage power (such as 120/240V or 240/480V) for end users.

It is designed for:

  • Overhead distribution systems
  • Utility power networks
  • Rural electrification projects
  • Residential power supply
  • Agricultural applications
  • Small commercial and industrial loads

The conventional type design provides a cost-effective solution for applications requiring simple, reliable, and easy-to-maintain distribution equipment.


Main Product Features

1. Reliable Pole-Mounted Design

The transformer adopts a compact overhead installation structure, allowing direct mounting on utility poles.

Advantages:

  • Suitable for overhead distribution lines
  • Requires minimal installation space
  • Easy maintenance and inspection
  • Ideal for rural and suburban networks
  • Reduced infrastructure cost

2. High-Efficiency Core Design

The transformer uses premium grain-oriented silicon steel laminations with optimized magnetic circuit design.

Benefits:

  • Low no-load losses
  • Improved energy efficiency
  • Reduced operating costs
  • Lower transformer noise
  • Extended service life

3. Durable Oil Insulation System

The transformer tank is filled with high-quality insulating oil, providing excellent insulation and heat dissipation performance.

Features:

  • ONAN cooling system
  • Excellent thermal performance
  • Reliable insulation strength
  • Stable operation under continuous load

4. Strong Outdoor Environmental Adaptability

Designed for outdoor utility applications, the transformer provides reliable operation under various environmental conditions.

Suitable for:

  • High temperature areas
  • Humid environments
  • Rain and dust conditions
  • Coastal areas with anti-corrosion treatment
  • Rural outdoor installations

Optional protection:

  • Enhanced corrosion-resistant coating
  • Stainless steel accessories
  • Special climate design

5. Flexible Voltage Configuration

The transformer supports different utility voltage requirements.

High Voltage Options:

  • 2.4kV
  • 4.16kV
  • 7.2kV
  • 11kV
  • 13.2kV
  • 13.8kV
  • 15kV
  • 24.9kV
  • 34.5kV

Low Voltage Options:

  • 120/240V
  • 240/480V
  • 277V
  • Customized voltage available


Structural Components

Transformer Tank

The tank is manufactured from high-strength steel with reliable sealing performance.

Features:

  • Leak-proof welded structure
  • Corrosion-resistant coating
  • Strong mechanical strength
  • Outdoor weather protection

Transformer Core

High-quality magnetic core materials reduce energy consumption.

Features:

  • Grain-oriented silicon steel
  • Low magnetic flux loss
  • Optimized core assembly
  • Reduced operating noise

Transformer Windings

Available winding materials:

Copper Winding

  • Higher conductivity
  • Better overload capability
  • Excellent reliability

Aluminum Winding

  • Lightweight
  • Cost-effective
  • Suitable for distribution applications

High Voltage Components

Optional HV components:

  • High voltage bushings
  • Lightning arresters
  • Fuse protection
  • Tap changer
  • Grounding terminals

Low Voltage Components

Low voltage side includes:

  • LV bushings
  • Secondary terminals
  • Cable connection points
  • Protective accessories

Typical Applications

1. Residential Distribution

Used for:

  • Rural homes
  • Residential communities
  • Suburban areas
  • Housing developments

Provides stable electricity supply for household loads.


2. Rural Electrification Projects

The 75kVA pole mounted transformer is widely used in rural grid expansion projects.

Applications:

  • Village electrification
  • Remote area power supply
  • Agricultural communities

Advantages:

  • Simple installation
  • Low maintenance requirements
  • Reliable operation

3. Agricultural Power Supply

Suitable for:

  • Farms
  • Irrigation systems
  • Agricultural processing facilities
  • Greenhouses

Provides dependable power for agricultural equipment.


4. Small Commercial & Industrial Loads

Applications:

  • Small workshops
  • Warehouses
  • Small factories
  • Service facilities

Product Advantages

Reliable Power Distribution

  • Stable voltage output
  • Strong insulation performance
  • Long operating life

Cost-Effective Solution

  • Simple structure
  • Easy installation
  • Low maintenance cost

Global Compatibility

Suitable for:

  • North America
  • Latin America
  • Africa
  • Southeast Asia
  • Middle East

Quality Manufacturing

Each 75kVA Conventional Type Single Phase Pole Mounted Transformer is manufactured under strict quality control procedures.

Production includes:

✔ Raw material inspection
✔ Core assembly inspection
✔ Winding process control
✔ Tank welding inspection
✔ Oil filling and sealing inspection
✔ Electrical performance testing
✔ Final factory inspection


Product Summary

The 75kVA Conventional Type Single Phase Pole Mounted Transformer is a dependable and economical solution for overhead distribution networks. With high-efficiency design, durable outdoor construction, flexible voltage options, and proven reliability, it is widely used in residential, agricultural, commercial, and utility power distribution projects worldwide.

The 75kVA Conventional Type Single Phase Pole Mounted Transformer is an oil-immersed distribution transformer designed for overhead power distribution systems. It is manufactured according to international standards and can be customized based on utility requirements, voltage levels, environmental conditions, and installation specifications.


General Specifications

Parameter Specification
Product Type Conventional Type Single Phase Pole Mounted Transformer
Rated Capacity 75kVA
Phase Single Phase
Frequency 50Hz / 60Hz
Installation Type Pole Mounted / Outdoor
Cooling Method ONAN (Oil Natural Air Natural)
Transformer Type Oil Immersed Distribution Transformer
Standard IEC 60076 / IEEE C57 / ANSI
Insulation Medium Mineral Oil / Environmentally Friendly Oil
Service Life ≥30 Years

Electrical Specifications

Parameter Specification
Rated Power 75kVA
Primary Voltage (HV) 2.4kV–34.5kV
Secondary Voltage (LV) 120/240V, 240/480V, Customized
Phase Single Phase
Frequency 50Hz / 60Hz
Vector Group Customized
Connection Type Single Phase Two-Winding
Tap Range ±2 × 2.5% / Customized
Tap Changer Type Off-Circuit Tap Changer

High Voltage Specifications

Parameter Specification
HV Bushing Porcelain / Polymer Bushing
HV Rated Voltage Up to 35kV
Lightning Impulse Withstand According to IEC/IEEE Standards
HV Protection Fuse Cutout / Optional
Surge Protection Lightning Arrester Optional

Low Voltage Specifications

Parameter Specification
LV Rated Voltage 120/240V, 240/480V
LV Bushing Porcelain / Polymer Type
LV Terminal Blade / Stud Terminal
Neutral Terminal Available
Grounding Terminal Standard

Transformer Core Specifications

Parameter Specification
Core Material Grain-Oriented Silicon Steel
Core Type Three-Leg / Step-Lap Core Design
Core Loss Low-Loss Design
Magnetic Circuit Optimized Magnetic Flux Distribution
Noise Level Low Noise Operation

Core Advantages:

✔ Reduced no-load losses
✔ Improved energy efficiency
✔ Lower operating temperature
✔ Longer service life


Winding Specifications

Parameter Specification
Winding Material Copper / Aluminum
Winding Type Layer Winding
Insulation Class Oil-Paper Insulation System
Temperature Rise 55℃ / 65℃
Short Circuit Capability Meets IEC/IEEE Requirements

Tank & Mechanical Structure

Parameter Specification
Tank Type Corrugated / Conventional Steel Tank
Material High Strength Steel Plate
Sealing Method Fully Sealed / Conservator Type
Surface Treatment Anti-Corrosion Coating
Paint System Outdoor Weather Resistant Coating
Lifting Structure Lifting Lugs Provided

Cooling & Insulation System

Parameter Specification
Cooling Type ONAN
Insulation Oil Mineral Oil / Bio-Based Oil Optional
Oil Expansion Conservator or Sealed Tank Design
Temperature Monitoring Optional

Environmental Specifications

Parameter Specification
Ambient Temperature -25℃ to +40℃
Maximum Temperature Customized up to 50℃
Installation Altitude ≤1000m
Relative Humidity ≤95%
Installation Environment Outdoor
Climate Adaptation Tropical / Desert / Coastal Optional

Protection & Accessories Options

The transformer can be equipped with:

Standard Accessories

✔ HV bushing
✔ LV bushing
✔ Grounding terminal
✔ Nameplate
✔ Drain valve
✔ Oil level indicator (optional)

Optional Accessories

  • Fuse cutout
  • Lightning arrester
  • Low voltage circuit breaker
  • Oil temperature indicator
  • Pressure relief device
  • Thermometer
  • Smart monitoring device

Performance Parameters

Parameter Specification
Efficiency High Efficiency Design
No-Load Loss According to IEC/DOE Requirements
Load Loss According to IEC/IEEE Requirements
Insulation Level According to Rated Voltage
Impedance Voltage Customized
Short Circuit Withstand According to Standards

Compliance Standards

The 75kVA Single Phase Pole Mounted Transformer can comply with:

  • IEC 60076 — Power Transformer Standard
  • IEEE C57 Series — Distribution Transformer Standard
  • ANSI C57.12 — Utility Transformer Standard
  • Regional utility specifications

Typical Configuration Example

75kVA Single Phase Pole Mounted Transformer

Item Specification
Rated Capacity 75kVA
Primary Voltage 13.8kV
Secondary Voltage 120/240V
Frequency 60Hz
Cooling ONAN
Winding Material Copper
Installation Pole Mounted
Application Residential & Rural Distribution

Custom Engineering Available

The transformer can be customized according to:

✔ Utility standards
✔ Country voltage requirements
✔ Climate conditions
✔ Installation method
✔ Protection requirements
✔ Customer specifications

The 75kVA Conventional Type Single Phase Pole Mounted Transformer provides a reliable, efficient, and cost-effective solution for overhead distribution networks, rural electrification, residential power supply, and utility infrastructure projects worldwide.

The 75kVA Conventional Type Single Phase Pole Mounted Transformer can be customized according to different utility requirements, regional power standards, installation environments, and project specifications. Flexible OEM solutions are available for voltage configuration, materials, protection accessories, and special operating conditions.


1. Electrical Parameter Customization

Rated Voltage Customization

The transformer can be designed according to different distribution network requirements.

High Voltage (HV) Options:

  • 2.4kV
  • 4.16kV
  • 7.2kV
  • 11kV
  • 12.47kV
  • 13.2kV
  • 13.8kV
  • 15kV
  • 20kV
  • 24.9kV
  • 33kV
  • 34.5kV

Low Voltage (LV) Options:

  • 120/240V
  • 220/380V
  • 230/400V
  • 240/480V
  • Customized voltage available

2. Frequency Customization

Available frequency options:

  • 50Hz
  • 60Hz

Suitable for different regional power systems:

  • North America
  • Latin America
  • Middle East
  • Africa
  • Southeast Asia

3. Winding Material Customization

Copper Winding

Advantages:

✔ Higher electrical conductivity
✔ Better overload capability
✔ Lower losses
✔ Longer service life

Recommended for:

  • Utility networks
  • Industrial applications
  • High reliability projects

Aluminum Winding

Advantages:

✔ Cost-effective solution
✔ Lightweight design
✔ Good electrical performance

Recommended for:

  • Rural electrification
  • General distribution systems
  • Cost-sensitive projects

4. Core Design Customization

Different core designs can be selected according to efficiency requirements.

Options:

  • Grain-Oriented Silicon Steel Core
  • Step-Lap Core Design
  • High-Efficiency Low-Loss Core
  • Amorphous Metal Core (Optional)

Benefits:

  • Reduced no-load losses
  • Improved energy efficiency
  • Lower operating temperature
  • Reduced electricity costs

5. Insulation & Cooling Customization

Insulating Oil Options:

  • Mineral Oil
  • Environmentally Friendly Vegetable Oil
  • Biodegradable Insulating Fluid

Cooling Design:

  • ONAN (Standard)
  • Enhanced cooling design for high-temperature environments

Suitable for:

  • Desert regions
  • Tropical climates
  • High-load operation

6. Protection Accessory Customization

Different protection solutions can be integrated.

Standard Accessories:

  • HV bushing
  • LV bushing
  • Grounding terminal
  • Nameplate
  • Drain valve

Optional Protection:

  • Fuse Cutout
  • Lightning Arrester
  • Surge Protection Device
  • Low Voltage Circuit Breaker
  • Oil Temperature Indicator
  • Pressure Relief Device
  • Oil Level Indicator
  • Smart Monitoring Unit

7. Tank Structure Customization

Different tank designs are available:

Corrugated Tank

Features:

  • Compact structure
  • Better heat dissipation
  • Low maintenance

Conventional Tank

Features:

  • Strong mechanical strength
  • Suitable for utility applications

Fully Sealed Tank

Advantages:

  • Prevents oil oxidation
  • Reduces maintenance
  • Extends transformer life

8. Environmental Adaptation Customization

Special designs are available for harsh environments.

High Temperature Areas

Suitable for:

  • Middle East
  • Africa
  • Desert regions

Options:

  • High-temperature insulation materials
  • Enhanced cooling design
  • Special coating

Coastal & High Salt Areas

Options:

  • Anti-corrosion coating
  • Stainless steel accessories
  • Salt spray protection treatment

Tropical & Humid Areas

Options:

  • Moisture-resistant insulation
  • Anti-condensation design
  • Improved sealing structure

9. Installation Customization

According to local installation requirements:

Options:

  • Pole mounting structure
  • Cross-arm mounting accessories
  • Special lifting arrangement
  • Customized dimensions
  • Utility-specific mounting design

10. Standards & Certification Customization

The transformer can be manufactured according to:

  • IEC 60076
  • IEEE C57 Series
  • ANSI C57.12
  • CSA Standards
  • AS/NZS Standards
  • Customer-specific utility standards

11. OEM Branding Customization

Available OEM services:

✔ Customer logo
✔ Customized nameplate
✔ Product identification labels
✔ Customized color coating
✔ Technical documentation with customer requirements


12. Documentation Support

Complete technical documents can be provided:

  • Product datasheet
  • Technical drawings
  • Outline dimensions
  • Wiring diagram
  • Factory test report
  • Installation manual
  • Operation instructions

Recommended Configurations for Different Markets

Market Recommended Customization
North America 13.8kV / 120-240V / IEEE Standard / Copper Winding
Middle East 13.8kV-33kV / High Temperature Design / Anti-Corrosion Coating
Africa 11kV / 230-400V / Durable Outdoor Design
Southeast Asia 11kV / Tropical Protection / High Humidity Design
Latin America 13.2kV / 120-240V / Utility Standard

OEM Customization Capability

With flexible manufacturing capability, the 75kVA Conventional Type Single Phase Pole Mounted Transformer can be configured for residential distribution, rural electrification, utility networks, and industrial power applications.

Customized voltage + reliable materials + advanced protection options provide a dependable transformer solution for global power distribution projects.

The 75kVA Conventional Type Single Phase Pole Mounted Transformer is carefully prepared for international transportation to ensure safe delivery, protection against environmental impact, and reliable operation after installation.

Each transformer undergoes final inspection before packing, including appearance checks, accessory verification, oil leakage inspection, and factory test confirmation.


1. Professional Factory Packing

Before shipment, every transformer is:

✔ Fully assembled and inspected
✔ Tested according to required standards
✔ Protected against moisture and dust
✔ Secured to prevent movement during transportation
✔ Prepared according to export shipping requirements


2. Standard Export Packing

Transformer Unit Protection

The transformer body is protected with:

  • Waterproof protective film
  • Anti-moisture wrapping
  • Surface protection materials
  • Shock-resistant fixing measures

Protection ensures:

  • No surface damage during handling
  • Protection against rain and humidity
  • Safe long-distance transportation

3. Wooden Case / Steel Frame Packing (Optional)

Different packing methods are available according to transportation requirements.

Steel Frame Packing

Recommended for:

  • Large quantity shipments
  • Container transportation
  • Long-distance sea freight

Advantages:

✔ Strong mechanical protection
✔ Easy lifting and securing
✔ Suitable for heavy-duty transportation


Wooden Case Packing

Recommended for:

  • Spare accessories
  • Small components
  • Special export requirements

Advantages:

✔ Impact protection
✔ Moisture resistance
✔ Export-friendly packaging


4. Container Loading

For international shipment, transformers are professionally loaded into containers.

Common methods:

  • 20ft container
  • 40ft container
  • Flat rack container (for special dimensions)

Loading process:

  1. Professional crane lifting
  2. Position alignment
  3. Strong fixing with steel supports
  4. Waterproof protection installation

5. Transportation Methods

Ocean Freight (Main Export Method)

Suitable for:

  • International orders
  • Bulk transformer shipments
  • Overseas projects

Common destinations:

  • Middle East
  • Africa
  • Southeast Asia
  • South America
  • North America

Shipping options:

  • FCL (Full Container Load)
  • LCL (Less Container Load)
  • Break bulk shipment

Land Transportation

Suitable for:

  • Domestic delivery
  • Regional projects
  • Cross-border transportation

Transport vehicles:

  • Flatbed truck
  • Heavy-duty trailer
  • Transformer transport vehicle

Railway Transportation

Available for:

  • Long-distance inland delivery
  • Large infrastructure projects

Advantages:

  • Stable transportation
  • Suitable for heavy equipment

6. Lifting & Handling Requirements

The transformer is designed with dedicated lifting points.

During loading and installation:

✔ Use approved lifting equipment
✔ Lift vertically from designated points
✔ Avoid collision and strong vibration
✔ Keep transformer upright during transportation
✔ Follow installation guidelines


7. Accessories Packing

Accessories are packed separately when required.

Included accessories may include:

  • Lightning arrester
  • Fuse cutout
  • Mounting brackets
  • Terminal connectors
  • Technical documents
  • Spare parts

Each accessory package is labeled for easy installation.


8. Shipping Documents

Complete export documentation is provided:

  • Commercial Invoice
  • Packing List
  • Certificate of Origin
  • Factory Test Report
  • Quality Certificate
  • Technical Datasheet
  • Installation Manual
  • Warranty Certificate

9. Delivery Terms

Flexible international trade terms are available:

Trade Term Service
EXW Factory pickup
FOB Delivery to loading port
CIF Delivery to destination port
DAP Delivery to project site
DDP Door-to-door delivery (where available)

10. Safe Delivery Guarantee

Every 75kVA Conventional Type Single Phase Pole Mounted Transformer is shipped with:

✔ Professional export packaging
✔ Secure transportation protection
✔ Complete technical documentation
✔ Factory inspection records
✔ Reliable logistics support

Through strict packing procedures and professional global logistics management, each transformer is delivered safely and ready for installation in residential, rural electrification, utility, and industrial distribution projects worldwide.

The 75kVA Conventional Type Single Phase Pole Mounted Transformer undergoes strict factory testing before shipment to ensure reliable electrical performance, insulation safety, mechanical strength, and long-term operation in outdoor distribution networks.

All tests are performed according to international transformer standards, including IEC 60076, IEEE C57, and ANSI C57 requirements. Each transformer is fully inspected and tested before leaving the factory.


1. Raw Material Inspection

Before production begins, all major materials are inspected to ensure quality and reliability.

Inspection Items:

✔ Silicon steel core quality
✔ Copper/aluminum conductor material
✔ Insulation paper performance
✔ Transformer oil quality
✔ Steel tank material
✔ Bushing and accessory specifications

Purpose:

  • Ensure stable transformer performance
  • Prevent material-related failures
  • Improve service life

2. Core Assembly Test

The transformer core is inspected after assembly.

Testing Includes:

  • Core stacking accuracy
  • Silicon steel sheet condition
  • Core grounding inspection
  • Magnetic circuit verification

Purpose:

✔ Reduce no-load losses
✔ Improve energy efficiency
✔ Minimize operating noise


3. Winding Manufacturing Inspection

The transformer windings undergo strict process control.

Inspection Items:

  • Winding dimensions
  • Turn number verification
  • Insulation structure
  • Conductor quality
  • Mechanical strength

Purpose:

  • Ensure correct voltage ratio
  • Improve short-circuit withstand capability
  • Guarantee reliable operation

4. Routine Electrical Tests

Winding Resistance Test

The resistance of HV and LV windings is measured.

Purpose:

  • Verify winding quality
  • Check electrical connections
  • Confirm resistance balance

Voltage Ratio Test

The transformer turns ratio is tested.

Purpose:

  • Confirm accurate voltage conversion
  • Verify tap position
  • Ensure correct output voltage

Polarity Test

Checks the relationship between primary and secondary windings.

Purpose:

  • Confirm correct internal connection
  • Ensure proper system installation

No-Load Loss and No-Load Current Test

The transformer is energized without load.

Measured:

  • No-load loss
  • Excitation current

Purpose:

✔ Verify core performance
✔ Confirm energy efficiency
✔ Check magnetic circuit quality


Load Loss and Impedance Test

The transformer is tested under short-circuit conditions.

Measured:

  • Load loss
  • Short-circuit impedance

Purpose:

  • Verify winding performance
  • Confirm efficiency
  • Ensure thermal design reliability

5. Insulation Performance Tests

Insulation Resistance Test

Insulation resistance is measured between:

  • HV winding and ground
  • LV winding and ground
  • HV and LV windings

Purpose:

✔ Verify insulation condition
✔ Prevent electrical breakdown
✔ Improve operating safety


Dielectric Withstand Test

High voltage withstand testing verifies insulation strength.

Purpose:

  • Detect insulation defects
  • Confirm electrical safety
  • Ensure reliable operation under voltage stress

Induced Voltage Test

Checks internal winding insulation performance.

Purpose:

  • Verify turn-to-turn insulation
  • Improve long-term reliability

6. Oil Quality & Leakage Testing

For oil-immersed pole mounted transformers:

Transformer Oil Test

Inspection includes:

  • Dielectric strength
  • Moisture content
  • Oil quality
  • Insulation performance

Oil Leakage Test

The transformer tank is tested to ensure:

  • No oil leakage
  • Reliable sealing
  • Long-term outdoor operation

7. Mechanical Structure Inspection

The transformer body is inspected before shipment.

Inspection items:

✔ Tank welding quality
✔ Surface coating condition
✔ Bushing installation
✔ Nameplate information
✔ Grounding connection
✔ Lifting structure


8. Final Performance Inspection

Before shipment, engineers perform final verification.

Includes:

  • Appearance inspection
  • Dimension check
  • Accessory confirmation
  • Electrical parameter verification
  • Test data review

Factory Routine Test Summary

Test Item Purpose
Winding Resistance Test Verify winding quality
Voltage Ratio Test Confirm voltage accuracy
Polarity Test Verify winding connection
No-Load Loss Test Check core efficiency
Load Loss Test Evaluate operating performance
Impedance Test Confirm transformer characteristics
Insulation Resistance Test Verify insulation reliability
Dielectric Test Check insulation strength
Oil Test Ensure insulation performance
Leakage Test Verify tank sealing
Final Inspection Confirm shipment quality

Test Documents Provided

Each 75kVA Conventional Type Single Phase Pole Mounted Transformer can be supplied with:

  • Factory Test Report
  • Routine Test Certificate
  • Quality Inspection Record
  • Product Datasheet
  • Technical Drawings
  • Installation Instructions

Quality Assurance

Every transformer is tested before delivery to ensure:

✔ Reliable outdoor operation
✔ Stable voltage performance
✔ High insulation strength
✔ Low energy loss
✔ Long service life

Strict manufacturer testing ensures that each 75kVA Single Phase Pole Mounted Transformer is ready for safe and reliable operation in utility distribution networks, rural electrification projects, residential power systems, and agricultural applications worldwide.

The 75kVA Conventional Type Single Phase Pole Mounted Transformer undergoes complete routine testing before shipment to verify electrical performance, insulation reliability, and manufacturing quality.

Each transformer is individually tested according to international standards, including IEC 60076, IEEE C57, and ANSI C57 requirements, ensuring safe operation and long-term reliability in overhead distribution networks.


1. Winding Resistance Test

The DC resistance of the high-voltage and low-voltage windings is measured using precision testing equipment.

Test Purpose:

  • Verify winding manufacturing quality
  • Confirm conductor connection reliability
  • Check resistance balance
  • Detect poor connections or production defects

Inspection Items:

✔ HV winding resistance
✔ LV winding resistance
✔ Temperature-corrected resistance values


2. Voltage Ratio Test

The transformer turns ratio is measured to confirm accurate voltage transformation.

Test Purpose:

  • Verify primary-to-secondary voltage ratio
  • Confirm tap position accuracy
  • Ensure correct output voltage

Inspection Items:

✔ Rated voltage ratio
✔ Tap position ratio deviation
✔ Phase relationship verification


3. Polarity Test

The transformer polarity is checked to confirm correct internal winding connections.

Test Purpose:

  • Ensure proper installation compatibility
  • Verify winding connection direction
  • Prevent connection errors during operation

4. No-Load Loss and No-Load Current Test

The transformer is energized at rated voltage without any load connected.

Measured Parameters:

  • No-load loss
  • No-load current

Purpose:

✔ Evaluate core quality
✔ Verify silicon steel performance
✔ Confirm transformer energy efficiency
✔ Check magnetic circuit design


5. Load Loss and Impedance Voltage Test

The transformer is tested under short-circuit conditions to measure load performance.

Measured Parameters:

  • Load loss
  • Short-circuit impedance

Purpose:

  • Verify winding performance
  • Confirm copper loss values
  • Ensure compliance with design requirements
  • Evaluate operating efficiency

6. Insulation Resistance Test

Insulation resistance is measured between different electrical parts.

Testing Points:

  • HV winding to ground
  • LV winding to ground
  • HV winding to LV winding

Purpose:

✔ Verify insulation condition
✔ Prevent insulation breakdown
✔ Ensure safe electrical operation


7. Dielectric Withstand Test

High-voltage withstand testing is performed to check the insulation system.

Test Purpose:

  • Verify insulation strength
  • Detect internal insulation defects
  • Confirm transformer safety under electrical stress

8. Induced Voltage Test

The transformer is subjected to increased frequency voltage to verify internal insulation performance.

Purpose:

  • Check turn-to-turn insulation
  • Verify winding insulation quality
  • Improve operational reliability

9. Transformer Oil Testing

For oil-immersed pole mounted transformers, insulating oil quality is inspected.

Test Items:

  • Dielectric breakdown voltage
  • Moisture content
  • Oil condition
  • Insulation performance

Purpose:

✔ Ensure effective insulation
✔ Improve heat dissipation
✔ Prevent internal discharge failures


10. Oil Leakage and Sealing Test

The transformer tank is tested for sealing performance.

Inspection Includes:

  • Tank weld inspection
  • Oil leakage inspection
  • Bushing sealing check
  • Pressure holding test

Purpose:

  • Ensure leak-free operation
  • Maintain insulation oil quality
  • Improve service life

11. Appearance and Assembly Inspection

Before shipment, the completed transformer receives a final inspection.

Inspection Items:

✔ Transformer dimensions
✔ Nameplate information
✔ Paint and coating quality
✔ Bushing installation
✔ Grounding terminals
✔ Accessories installation


Routine Testing Summary

Routine Test Purpose
Winding Resistance Test Verify winding quality
Voltage Ratio Test Confirm accurate voltage conversion
Polarity Test Check winding connection
No-Load Loss Test Evaluate core performance
No-Load Current Test Check excitation characteristics
Load Loss Test Verify operating efficiency
Impedance Test Confirm electrical characteristics
Insulation Resistance Test Verify insulation reliability
Dielectric Test Confirm insulation strength
Oil Test Ensure insulation and cooling performance
Leakage Test Verify tank sealing
Final Inspection Confirm shipment readiness

Factory Test Documentation

After completing routine tests, customers can receive:

  • Factory Routine Test Report
  • Electrical Test Certificate
  • Quality Inspection Report
  • Product Datasheet
  • Technical Drawings
  • Installation Manual

Quality Assurance

Every 75kVA Conventional Type Single Phase Pole Mounted Transformer is fully tested before delivery to ensure:

✔ Reliable power distribution performance
✔ Safe outdoor operation
✔ Low energy losses
✔ Strong insulation capability
✔ Long service life

Strict routine testing guarantees that each transformer is ready for dependable operation in utility networks, rural electrification systems, residential distribution, and agricultural power supply projects worldwide.

The 75kVA Conventional Type Single Phase Pole Mounted Transformer is a reliable oil-immersed distribution transformer designed for overhead power distribution networks. It is mainly used to step down medium voltage electricity from utility distribution lines to low voltage power for residential, commercial, agricultural, and small industrial users.

With its compact structure, easy installation, low maintenance requirements, and excellent outdoor durability, it is widely used in utility distribution systems, rural electrification projects, and decentralized power supply applications.


1. Residential Power Distribution

The 75kVA single phase pole mounted transformer is commonly used for supplying electricity to residential areas through overhead distribution lines.

Typical Applications:

  • Rural residential communities
  • Suburban housing areas
  • Villages and small towns
  • Single-family homes
  • Residential development projects

Advantages:

✔ Stable household power supply
✔ Suitable for overhead distribution systems
✔ Compact installation design
✔ Easy maintenance and inspection
✔ Cost-effective power distribution solution


2. Rural Electrification Projects

The transformer is widely used in rural grid expansion and electrification programs where reliable and economical power supply is required.

Typical Applications:

  • Remote villages
  • Agricultural communities
  • Rural public facilities
  • Off-grid extension projects

Benefits:

✔ Simple pole installation
✔ Reduced infrastructure costs
✔ Reliable operation in outdoor environments
✔ Suitable for long-distance distribution networks


3. Agricultural Power Supply

The 75kVA pole mounted transformer provides dependable electricity for agricultural operations.

Typical Applications:

  • Farms
  • Irrigation systems
  • Greenhouses
  • Livestock facilities
  • Agricultural processing equipment

Advantages:

✔ Supports motor loads and agricultural equipment
✔ Reliable operation under outdoor conditions
✔ Low maintenance requirements
✔ Suitable for distributed rural power systems


4. Small Commercial Applications

The transformer can supply power for small commercial facilities requiring stable low-voltage electricity.

Typical Applications:

  • Small shops
  • Offices
  • Restaurants
  • Service stations
  • Local business facilities

Benefits:

✔ Reliable voltage supply
✔ Easy installation
✔ Suitable for independent power distribution


5. Small Industrial Facilities

The 75kVA transformer is suitable for light industrial and workshop applications.

Typical Applications:

  • Small factories
  • Workshops
  • Warehouses
  • Repair facilities
  • Processing plants

Advantages:

✔ Continuous power supply capability
✔ Strong outdoor adaptability
✔ Flexible voltage configuration
✔ Reduced installation cost


6. Utility Distribution Networks

Utility companies commonly deploy conventional pole mounted transformers in overhead distribution systems.

Typical Applications:

  • Distribution feeders
  • Local grid networks
  • Community power supply
  • Utility expansion projects

Benefits:

✔ Proven utility technology
✔ Easy replacement and maintenance
✔ Compatible with overhead line systems
✔ Long operational life


7. Renewable Energy & Distributed Generation

The transformer can be integrated into small renewable energy distribution systems.

Typical Applications:

  • Solar distributed generation
  • Rural solar power systems
  • Microgrid projects
  • Small renewable energy installations

Advantages:

✔ Reliable grid connection
✔ Suitable for outdoor installation
✔ Flexible voltage options
✔ Supports decentralized power supply


8. Public Infrastructure Projects

The transformer can provide power for small-scale public facilities.

Typical Applications:

  • Schools
  • Clinics
  • Community centers
  • Water pumping stations
  • Municipal facilities

Benefits:

✔ Reliable electricity access
✔ Simple installation
✔ Suitable for remote locations


Typical Application Environments

The 75kVA Conventional Type Single Phase Pole Mounted Transformer is suitable for:

✔ Rural areas
✔ Suburban communities
✔ Agricultural regions
✔ Outdoor utility networks
✔ Tropical climates
✔ Desert regions
✔ High-temperature environments


Recommended Markets

Region Typical Applications
Africa Rural electrification, villages, agricultural power supply
Middle East Remote communities, farms, infrastructure projects
Southeast Asia Rural grids, residential areas, commercial users
Latin America Utility distribution, residential electrification
North America Overhead residential distribution systems

Why Choose 75kVA Single Phase Pole Mounted Transformer?

✔ Reliable overhead distribution solution
✔ Compact and easy installation
✔ Low operating and maintenance cost
✔ High outdoor durability
✔ Flexible voltage customization
✔ Suitable for utility and private power networks

The 75kVA Conventional Type Single Phase Pole Mounted Transformer provides a dependable and economical power distribution solution for residential communities, rural electrification, agricultural applications, and utility networks worldwide.

1. What is a 75kVA Conventional Type Single Phase Pole Mounted Transformer?

The 75kVA Conventional Type Single Phase Pole Mounted Transformer is an oil-immersed distribution transformer designed for overhead electrical distribution systems. It reduces medium voltage electricity from utility distribution lines to low voltage power suitable for residential, agricultural, commercial, and small industrial applications.

It is commonly installed on utility poles and provides a reliable, economical solution for decentralized power distribution.


2. What are the main applications of a 75kVA pole mounted transformer?

The transformer is widely used in:

  • Residential communities
  • Rural electrification projects
  • Agricultural power supply
  • Small commercial buildings
  • Workshops and small factories
  • Utility distribution networks
  • Solar distributed power systems
  • Remote area electrification

3. What voltage levels are available for the 75kVA transformer?

The transformer can be customized according to different country and utility requirements.

High Voltage Side:

  • 2.4kV
  • 4.16kV
  • 7.2kV
  • 11kV
  • 12.47kV
  • 13.2kV
  • 13.8kV
  • 15kV
  • 20kV
  • 24.9kV
  • 33kV
  • 34.5kV

Low Voltage Side:

  • 120/240V
  • 220/380V
  • 230/400V
  • 240/480V

Customized voltage configurations are available.


4. Is the 75kVA transformer suitable for outdoor installation?

Yes. The transformer is designed for outdoor operation and can withstand various environmental conditions.

Features include:

  • Weather-resistant tank design
  • Outdoor anti-corrosion coating
  • Oil insulation and cooling system
  • UV-resistant surface protection
  • Reliable sealing structure

It can be customized for:

  • Desert environments
  • Tropical climates
  • Coastal areas
  • High humidity regions

5. What type of cooling system does this transformer use?

The standard cooling method is:

ONAN (Oil Natural Air Natural)

This means:

  • Transformer oil transfers heat from internal components
  • External air cools the tank surface naturally
  • No additional cooling equipment is required

This design provides reliable and low-maintenance operation.


6. What winding materials are available?

Customers can choose:

Copper Winding

Advantages:

  • Higher conductivity
  • Lower electrical losses
  • Better overload capability
  • Longer service life

Aluminum Winding

Advantages:

  • Cost-effective
  • Lightweight
  • Suitable for standard distribution applications

7. What standards does the transformer comply with?

The transformer can be manufactured according to:

  • IEC 60076 Power Transformer Standard
  • IEEE C57 Distribution Transformer Standard
  • ANSI C57.12 Utility Transformer Standard
  • Customer-specific utility standards

8. What tests are performed before delivery?

Every transformer undergoes strict factory testing.

Routine tests include:

✔ Winding resistance test
✔ Voltage ratio test
✔ Polarity test
✔ No-load loss test
✔ No-load current test
✔ Load loss test
✔ Impedance test
✔ Insulation resistance test
✔ Dielectric withstand test
✔ Transformer oil test
✔ Leakage test
✔ Final appearance inspection

A complete factory test report can be provided.


9. Can the transformer be customized?

Yes. OEM customization is available.

Customization options include:

  • HV/LV voltage
  • Frequency (50Hz/60Hz)
  • Copper or aluminum winding
  • Core material
  • Transformer oil type
  • Tank design
  • Protection accessories
  • Mounting structure
  • Customer logo and nameplate

10. What protection accessories are available?

Optional accessories include:

  • Fuse cutout
  • Lightning arrester
  • Surge protection device
  • Low voltage circuit breaker
  • Oil level indicator
  • Oil temperature indicator
  • Pressure relief device
  • Smart monitoring system

11. What is the expected service life of a 75kVA pole mounted transformer?

With proper installation and maintenance, the transformer can typically provide:

30 years or more of reliable service life

Service life depends on:

  • Operating load
  • Environmental conditions
  • Maintenance practices
  • Installation quality

12. How is the transformer transported?

The transformer is prepared for safe international shipment.

Transportation methods:

  • Sea freight
  • Land transportation
  • Railway transportation

Packing includes:

  • Waterproof protection
  • Anti-impact protection
  • Secure fixing
  • Export standard packaging

13. What documents are provided with the transformer?

Customers can receive:

  • Product datasheet
  • Technical specifications
  • Factory test report
  • Quality certificate
  • Installation manual
  • Operation instructions
  • Packing list
  • Certificate of origin

14. What is the difference between conventional type and CSP pole mounted transformers?

Conventional Type Transformer:

  • Basic and economical design
  • Requires external protection devices
  • Commonly used in utility distribution systems

CSP (Completely Self-Protected) Transformer:

  • Includes built-in protection functions
  • Contains internal protection components
  • Provides additional safety features

The conventional type is preferred where external protection systems are already available.


15. Why choose a 75kVA Single Phase Pole Mounted Transformer?

Main advantages:

✔ Reliable overhead distribution solution
✔ Compact and easy installation
✔ Low maintenance requirements
✔ High outdoor durability
✔ Flexible voltage options
✔ Cost-effective power supply solution
✔ Suitable for global utility applications


The 75kVA Conventional Type Single Phase Pole Mounted Transformer is a proven solution for reliable electricity distribution, providing efficient and durable power supply for residential, rural, agricultural, and utility projects worldwide.

75kVA Conventional Type Single Phase Pole Mounted Transformer75kVA Conventional Type Single Phase Pole Mounted Transformer

Click on the inquiry