NPC ELECTRIC has been specialized in manufacturing 75kVA Conventional Type Single Phase pole Mounted transformer for more than 20 years, which complies with international standards such as ANSI/IEEE C57, IEC60076 and other standards. Its main function is to convert high voltage electricity (such as 11kV, 13.8kV, etc.) into low voltage electricity (such as 120V/240V), providing stable and reliable power supply to end users. It is suitable for residential, commercial, agricultural and small industrial loads. Typical specifications include mineral oil insulation (ONAN cooling), aluminum or copper windings, primary voltages 2.4kV–34.5kV grounded wye or delta (common: 7200/12470GrdY, 7620/13200GrdY, 12470GrdY/7200, 24940GrdY/14400, 34500GrdY/19920), secondary 120/240V or 240/120V split-phase, BIL ratings 95–150kV HV / 30kV LV, impedance typically 2.0–4.0%, ±2×2.5% or 5-position tap changer, conventional or CSP (completely self-protected) configurations with internal fuses, lightning arresters, weak-link protection, pressure relief valve, oil sight gauge, and ANSI 70 gray tank finish. Efficiency typically reaches 99.17–99.19% at 50% load per DOE levels, with low sound levels and corrosion-resistant hardware for extended outdoor service.The 75kVA Conventional Type Single Phase Pole Mounted Transformer is a reliable oil-immersed distribution transformer designed for overhead power distribution networks. It is mainly used to step down medium-voltage electricity from utility distribution lines into low-voltage power suitable for residential, commercial, agricultural, and small industrial applications.
With a compact structure, high electrical efficiency, and excellent outdoor durability, this transformer is widely installed on utility poles in rural electrification systems, residential communities, and distribution networks where overhead power transmission is preferred.
The transformer adopts a high-quality grain-oriented silicon steel core, copper or aluminum windings, mineral oil insulation, and ONAN cooling technology to ensure stable operation, low energy loss, and long service life. It can be customized according to different grid standards, including voltage levels, insulation systems, protection configurations, and installation requirements.
Product Overview
The 75kVA Single Phase Pole Mounted Transformer converts medium voltage electricity (such as 11kV, 13.8kV, or other distribution voltages) into low voltage power (such as 120/240V or 240/480V) for end users.
It is designed for:
- Overhead distribution systems
- Utility power networks
- Rural electrification projects
- Residential power supply
- Agricultural applications
- Small commercial and industrial loads
The conventional type design provides a cost-effective solution for applications requiring simple, reliable, and easy-to-maintain distribution equipment.
Main Product Features
1. Reliable Pole-Mounted Design
The transformer adopts a compact overhead installation structure, allowing direct mounting on utility poles.
Advantages:
- Suitable for overhead distribution lines
- Requires minimal installation space
- Easy maintenance and inspection
- Ideal for rural and suburban networks
- Reduced infrastructure cost
2. High-Efficiency Core Design
The transformer uses premium grain-oriented silicon steel laminations with optimized magnetic circuit design.
Benefits:
- Low no-load losses
- Improved energy efficiency
- Reduced operating costs
- Lower transformer noise
- Extended service life
3. Durable Oil Insulation System
The transformer tank is filled with high-quality insulating oil, providing excellent insulation and heat dissipation performance.
Features:
- ONAN cooling system
- Excellent thermal performance
- Reliable insulation strength
- Stable operation under continuous load
4. Strong Outdoor Environmental Adaptability
Designed for outdoor utility applications, the transformer provides reliable operation under various environmental conditions.
Suitable for:
- High temperature areas
- Humid environments
- Rain and dust conditions
- Coastal areas with anti-corrosion treatment
- Rural outdoor installations
Optional protection:
- Enhanced corrosion-resistant coating
- Stainless steel accessories
- Special climate design
5. Flexible Voltage Configuration
The transformer supports different utility voltage requirements.
High Voltage Options:
- 2.4kV
- 4.16kV
- 7.2kV
- 11kV
- 13.2kV
- 13.8kV
- 15kV
- 24.9kV
- 34.5kV
Low Voltage Options:
- 120/240V
- 240/480V
- 277V
- Customized voltage available
Structural Components
Transformer Tank
The tank is manufactured from high-strength steel with reliable sealing performance.
Features:
- Leak-proof welded structure
- Corrosion-resistant coating
- Strong mechanical strength
- Outdoor weather protection
Transformer Core
High-quality magnetic core materials reduce energy consumption.
Features:
- Grain-oriented silicon steel
- Low magnetic flux loss
- Optimized core assembly
- Reduced operating noise
Transformer Windings
Available winding materials:
Copper Winding
- Higher conductivity
- Better overload capability
- Excellent reliability
Aluminum Winding
- Lightweight
- Cost-effective
- Suitable for distribution applications
High Voltage Components
Optional HV components:
- High voltage bushings
- Lightning arresters
- Fuse protection
- Tap changer
- Grounding terminals
Low Voltage Components
Low voltage side includes:
- LV bushings
- Secondary terminals
- Cable connection points
- Protective accessories
Typical Applications
1. Residential Distribution
Used for:
- Rural homes
- Residential communities
- Suburban areas
- Housing developments
Provides stable electricity supply for household loads.
2. Rural Electrification Projects
The 75kVA pole mounted transformer is widely used in rural grid expansion projects.
Applications:
- Village electrification
- Remote area power supply
- Agricultural communities
Advantages:
- Simple installation
- Low maintenance requirements
- Reliable operation
3. Agricultural Power Supply
Suitable for:
- Farms
- Irrigation systems
- Agricultural processing facilities
- Greenhouses
Provides dependable power for agricultural equipment.
4. Small Commercial & Industrial Loads
Applications:
- Small workshops
- Warehouses
- Small factories
- Service facilities
Product Advantages
Reliable Power Distribution
- Stable voltage output
- Strong insulation performance
- Long operating life
Cost-Effective Solution
- Simple structure
- Easy installation
- Low maintenance cost
Global Compatibility
Suitable for:
- North America
- Latin America
- Africa
- Southeast Asia
- Middle East
Quality Manufacturing
Each 75kVA Conventional Type Single Phase Pole Mounted Transformer is manufactured under strict quality control procedures.
Production includes:
✔ Raw material inspection
✔ Core assembly inspection
✔ Winding process control
✔ Tank welding inspection
✔ Oil filling and sealing inspection
✔ Electrical performance testing
✔ Final factory inspection
Product Summary
The 75kVA Conventional Type Single Phase Pole Mounted Transformer is a dependable and economical solution for overhead distribution networks. With high-efficiency design, durable outdoor construction, flexible voltage options, and proven reliability, it is widely used in residential, agricultural, commercial, and utility power distribution projects worldwide.
The 75kVA Conventional Type Single Phase Pole Mounted Transformer is an oil-immersed distribution transformer designed for overhead power distribution systems. It is manufactured according to international standards and can be customized based on utility requirements, voltage levels, environmental conditions, and installation specifications.
General Specifications
| Parameter |
Specification |
| Product Type |
Conventional Type Single Phase Pole Mounted Transformer |
| Rated Capacity |
75kVA |
| Phase |
Single Phase |
| Frequency |
50Hz / 60Hz |
| Installation Type |
Pole Mounted / Outdoor |
| Cooling Method |
ONAN (Oil Natural Air Natural) |
| Transformer Type |
Oil Immersed Distribution Transformer |
| Standard |
IEC 60076 / IEEE C57 / ANSI |
| Insulation Medium |
Mineral Oil / Environmentally Friendly Oil |
| Service Life |
≥30 Years |
Electrical Specifications
| Parameter |
Specification |
| Rated Power |
75kVA |
| Primary Voltage (HV) |
2.4kV–34.5kV |
| Secondary Voltage (LV) |
120/240V, 240/480V, Customized |
| Phase |
Single Phase |
| Frequency |
50Hz / 60Hz |
| Vector Group |
Customized |
| Connection Type |
Single Phase Two-Winding |
| Tap Range |
±2 × 2.5% / Customized |
| Tap Changer Type |
Off-Circuit Tap Changer |
High Voltage Specifications
| Parameter |
Specification |
| HV Bushing |
Porcelain / Polymer Bushing |
| HV Rated Voltage |
Up to 35kV |
| Lightning Impulse Withstand |
According to IEC/IEEE Standards |
| HV Protection |
Fuse Cutout / Optional |
| Surge Protection |
Lightning Arrester Optional |
Low Voltage Specifications
| Parameter |
Specification |
| LV Rated Voltage |
120/240V, 240/480V |
| LV Bushing |
Porcelain / Polymer Type |
| LV Terminal |
Blade / Stud Terminal |
| Neutral Terminal |
Available |
| Grounding Terminal |
Standard |
Transformer Core Specifications
| Parameter |
Specification |
| Core Material |
Grain-Oriented Silicon Steel |
| Core Type |
Three-Leg / Step-Lap Core Design |
| Core Loss |
Low-Loss Design |
| Magnetic Circuit |
Optimized Magnetic Flux Distribution |
| Noise Level |
Low Noise Operation |
Core Advantages:
✔ Reduced no-load losses
✔ Improved energy efficiency
✔ Lower operating temperature
✔ Longer service life
Winding Specifications
| Parameter |
Specification |
| Winding Material |
Copper / Aluminum |
| Winding Type |
Layer Winding |
| Insulation Class |
Oil-Paper Insulation System |
| Temperature Rise |
55℃ / 65℃ |
| Short Circuit Capability |
Meets IEC/IEEE Requirements |
Tank & Mechanical Structure
| Parameter |
Specification |
| Tank Type |
Corrugated / Conventional Steel Tank |
| Material |
High Strength Steel Plate |
| Sealing Method |
Fully Sealed / Conservator Type |
| Surface Treatment |
Anti-Corrosion Coating |
| Paint System |
Outdoor Weather Resistant Coating |
| Lifting Structure |
Lifting Lugs Provided |
Cooling & Insulation System
| Parameter |
Specification |
| Cooling Type |
ONAN |
| Insulation Oil |
Mineral Oil / Bio-Based Oil Optional |
| Oil Expansion |
Conservator or Sealed Tank Design |
| Temperature Monitoring |
Optional |
Environmental Specifications
| Parameter |
Specification |
| Ambient Temperature |
-25℃ to +40℃ |
| Maximum Temperature |
Customized up to 50℃ |
| Installation Altitude |
≤1000m |
| Relative Humidity |
≤95% |
| Installation Environment |
Outdoor |
| Climate Adaptation |
Tropical / Desert / Coastal Optional |
Protection & Accessories Options
The transformer can be equipped with:
Standard Accessories
✔ HV bushing
✔ LV bushing
✔ Grounding terminal
✔ Nameplate
✔ Drain valve
✔ Oil level indicator (optional)
Optional Accessories
- Fuse cutout
- Lightning arrester
- Low voltage circuit breaker
- Oil temperature indicator
- Pressure relief device
- Thermometer
- Smart monitoring device
Performance Parameters
| Parameter |
Specification |
| Efficiency |
High Efficiency Design |
| No-Load Loss |
According to IEC/DOE Requirements |
| Load Loss |
According to IEC/IEEE Requirements |
| Insulation Level |
According to Rated Voltage |
| Impedance Voltage |
Customized |
| Short Circuit Withstand |
According to Standards |
Compliance Standards
The 75kVA Single Phase Pole Mounted Transformer can comply with:
- IEC 60076 — Power Transformer Standard
- IEEE C57 Series — Distribution Transformer Standard
- ANSI C57.12 — Utility Transformer Standard
- Regional utility specifications
Typical Configuration Example
75kVA Single Phase Pole Mounted Transformer
| Item |
Specification |
| Rated Capacity |
75kVA |
| Primary Voltage |
13.8kV |
| Secondary Voltage |
120/240V |
| Frequency |
60Hz |
| Cooling |
ONAN |
| Winding Material |
Copper |
| Installation |
Pole Mounted |
| Application |
Residential & Rural Distribution |
Custom Engineering Available
The transformer can be customized according to:
✔ Utility standards
✔ Country voltage requirements
✔ Climate conditions
✔ Installation method
✔ Protection requirements
✔ Customer specifications
The 75kVA Conventional Type Single Phase Pole Mounted Transformer provides a reliable, efficient, and cost-effective solution for overhead distribution networks, rural electrification, residential power supply, and utility infrastructure projects worldwide.
The 75kVA Conventional Type Single Phase Pole Mounted Transformer can be customized according to different utility requirements, regional power standards, installation environments, and project specifications. Flexible OEM solutions are available for voltage configuration, materials, protection accessories, and special operating conditions.
1. Electrical Parameter Customization
Rated Voltage Customization
The transformer can be designed according to different distribution network requirements.
High Voltage (HV) Options:
- 2.4kV
- 4.16kV
- 7.2kV
- 11kV
- 12.47kV
- 13.2kV
- 13.8kV
- 15kV
- 20kV
- 24.9kV
- 33kV
- 34.5kV
Low Voltage (LV) Options:
- 120/240V
- 220/380V
- 230/400V
- 240/480V
- Customized voltage available
2. Frequency Customization
Available frequency options:
Suitable for different regional power systems:
- North America
- Latin America
- Middle East
- Africa
- Southeast Asia
3. Winding Material Customization
Copper Winding
Advantages:
✔ Higher electrical conductivity
✔ Better overload capability
✔ Lower losses
✔ Longer service life
Recommended for:
- Utility networks
- Industrial applications
- High reliability projects
Aluminum Winding
Advantages:
✔ Cost-effective solution
✔ Lightweight design
✔ Good electrical performance
Recommended for:
- Rural electrification
- General distribution systems
- Cost-sensitive projects
4. Core Design Customization
Different core designs can be selected according to efficiency requirements.
Options:
- Grain-Oriented Silicon Steel Core
- Step-Lap Core Design
- High-Efficiency Low-Loss Core
- Amorphous Metal Core (Optional)
Benefits:
- Reduced no-load losses
- Improved energy efficiency
- Lower operating temperature
- Reduced electricity costs
5. Insulation & Cooling Customization
Insulating Oil Options:
- Mineral Oil
- Environmentally Friendly Vegetable Oil
- Biodegradable Insulating Fluid
Cooling Design:
- ONAN (Standard)
- Enhanced cooling design for high-temperature environments
Suitable for:
- Desert regions
- Tropical climates
- High-load operation
6. Protection Accessory Customization
Different protection solutions can be integrated.
Standard Accessories:
- HV bushing
- LV bushing
- Grounding terminal
- Nameplate
- Drain valve
Optional Protection:
- Fuse Cutout
- Lightning Arrester
- Surge Protection Device
- Low Voltage Circuit Breaker
- Oil Temperature Indicator
- Pressure Relief Device
- Oil Level Indicator
- Smart Monitoring Unit
7. Tank Structure Customization
Different tank designs are available:
Corrugated Tank
Features:
- Compact structure
- Better heat dissipation
- Low maintenance
Conventional Tank
Features:
- Strong mechanical strength
- Suitable for utility applications
Fully Sealed Tank
Advantages:
- Prevents oil oxidation
- Reduces maintenance
- Extends transformer life
8. Environmental Adaptation Customization
Special designs are available for harsh environments.
High Temperature Areas
Suitable for:
- Middle East
- Africa
- Desert regions
Options:
- High-temperature insulation materials
- Enhanced cooling design
- Special coating
Coastal & High Salt Areas
Options:
- Anti-corrosion coating
- Stainless steel accessories
- Salt spray protection treatment
Tropical & Humid Areas
Options:
- Moisture-resistant insulation
- Anti-condensation design
- Improved sealing structure
9. Installation Customization
According to local installation requirements:
Options:
- Pole mounting structure
- Cross-arm mounting accessories
- Special lifting arrangement
- Customized dimensions
- Utility-specific mounting design
10. Standards & Certification Customization
The transformer can be manufactured according to:
- IEC 60076
- IEEE C57 Series
- ANSI C57.12
- CSA Standards
- AS/NZS Standards
- Customer-specific utility standards
11. OEM Branding Customization
Available OEM services:
✔ Customer logo
✔ Customized nameplate
✔ Product identification labels
✔ Customized color coating
✔ Technical documentation with customer requirements
12. Documentation Support
Complete technical documents can be provided:
- Product datasheet
- Technical drawings
- Outline dimensions
- Wiring diagram
- Factory test report
- Installation manual
- Operation instructions
Recommended Configurations for Different Markets
| Market |
Recommended Customization |
| North America |
13.8kV / 120-240V / IEEE Standard / Copper Winding |
| Middle East |
13.8kV-33kV / High Temperature Design / Anti-Corrosion Coating |
| Africa |
11kV / 230-400V / Durable Outdoor Design |
| Southeast Asia |
11kV / Tropical Protection / High Humidity Design |
| Latin America |
13.2kV / 120-240V / Utility Standard |
OEM Customization Capability
With flexible manufacturing capability, the 75kVA Conventional Type Single Phase Pole Mounted Transformer can be configured for residential distribution, rural electrification, utility networks, and industrial power applications.
Customized voltage + reliable materials + advanced protection options provide a dependable transformer solution for global power distribution projects.
The 75kVA Conventional Type Single Phase Pole Mounted Transformer is carefully prepared for international transportation to ensure safe delivery, protection against environmental impact, and reliable operation after installation.
Each transformer undergoes final inspection before packing, including appearance checks, accessory verification, oil leakage inspection, and factory test confirmation.
1. Professional Factory Packing
Before shipment, every transformer is:
✔ Fully assembled and inspected
✔ Tested according to required standards
✔ Protected against moisture and dust
✔ Secured to prevent movement during transportation
✔ Prepared according to export shipping requirements
2. Standard Export Packing
Transformer Unit Protection
The transformer body is protected with:
- Waterproof protective film
- Anti-moisture wrapping
- Surface protection materials
- Shock-resistant fixing measures
Protection ensures:
- No surface damage during handling
- Protection against rain and humidity
- Safe long-distance transportation
3. Wooden Case / Steel Frame Packing (Optional)
Different packing methods are available according to transportation requirements.
Steel Frame Packing
Recommended for:
- Large quantity shipments
- Container transportation
- Long-distance sea freight
Advantages:
✔ Strong mechanical protection
✔ Easy lifting and securing
✔ Suitable for heavy-duty transportation
Wooden Case Packing
Recommended for:
- Spare accessories
- Small components
- Special export requirements
Advantages:
✔ Impact protection
✔ Moisture resistance
✔ Export-friendly packaging
4. Container Loading
For international shipment, transformers are professionally loaded into containers.
Common methods:
- 20ft container
- 40ft container
- Flat rack container (for special dimensions)
Loading process:
- Professional crane lifting
- Position alignment
- Strong fixing with steel supports
- Waterproof protection installation
5. Transportation Methods
Ocean Freight (Main Export Method)
Suitable for:
- International orders
- Bulk transformer shipments
- Overseas projects
Common destinations:
- Middle East
- Africa
- Southeast Asia
- South America
- North America
Shipping options:
- FCL (Full Container Load)
- LCL (Less Container Load)
- Break bulk shipment
Land Transportation
Suitable for:
- Domestic delivery
- Regional projects
- Cross-border transportation
Transport vehicles:
- Flatbed truck
- Heavy-duty trailer
- Transformer transport vehicle
Railway Transportation
Available for:
- Long-distance inland delivery
- Large infrastructure projects
Advantages:
- Stable transportation
- Suitable for heavy equipment
6. Lifting & Handling Requirements
The transformer is designed with dedicated lifting points.
During loading and installation:
✔ Use approved lifting equipment
✔ Lift vertically from designated points
✔ Avoid collision and strong vibration
✔ Keep transformer upright during transportation
✔ Follow installation guidelines
7. Accessories Packing
Accessories are packed separately when required.
Included accessories may include:
- Lightning arrester
- Fuse cutout
- Mounting brackets
- Terminal connectors
- Technical documents
- Spare parts
Each accessory package is labeled for easy installation.
8. Shipping Documents
Complete export documentation is provided:
- Commercial Invoice
- Packing List
- Certificate of Origin
- Factory Test Report
- Quality Certificate
- Technical Datasheet
- Installation Manual
- Warranty Certificate
9. Delivery Terms
Flexible international trade terms are available:
| Trade Term |
Service |
| EXW |
Factory pickup |
| FOB |
Delivery to loading port |
| CIF |
Delivery to destination port |
| DAP |
Delivery to project site |
| DDP |
Door-to-door delivery (where available) |
10. Safe Delivery Guarantee
Every 75kVA Conventional Type Single Phase Pole Mounted Transformer is shipped with:
✔ Professional export packaging
✔ Secure transportation protection
✔ Complete technical documentation
✔ Factory inspection records
✔ Reliable logistics support
Through strict packing procedures and professional global logistics management, each transformer is delivered safely and ready for installation in residential, rural electrification, utility, and industrial distribution projects worldwide.
The 75kVA Conventional Type Single Phase Pole Mounted Transformer undergoes strict factory testing before shipment to ensure reliable electrical performance, insulation safety, mechanical strength, and long-term operation in outdoor distribution networks.
All tests are performed according to international transformer standards, including IEC 60076, IEEE C57, and ANSI C57 requirements. Each transformer is fully inspected and tested before leaving the factory.
1. Raw Material Inspection
Before production begins, all major materials are inspected to ensure quality and reliability.
Inspection Items:
✔ Silicon steel core quality
✔ Copper/aluminum conductor material
✔ Insulation paper performance
✔ Transformer oil quality
✔ Steel tank material
✔ Bushing and accessory specifications
Purpose:
- Ensure stable transformer performance
- Prevent material-related failures
- Improve service life
2. Core Assembly Test
The transformer core is inspected after assembly.
Testing Includes:
- Core stacking accuracy
- Silicon steel sheet condition
- Core grounding inspection
- Magnetic circuit verification
Purpose:
✔ Reduce no-load losses
✔ Improve energy efficiency
✔ Minimize operating noise
3. Winding Manufacturing Inspection
The transformer windings undergo strict process control.
Inspection Items:
- Winding dimensions
- Turn number verification
- Insulation structure
- Conductor quality
- Mechanical strength
Purpose:
- Ensure correct voltage ratio
- Improve short-circuit withstand capability
- Guarantee reliable operation
4. Routine Electrical Tests
Winding Resistance Test
The resistance of HV and LV windings is measured.
Purpose:
- Verify winding quality
- Check electrical connections
- Confirm resistance balance
Voltage Ratio Test
The transformer turns ratio is tested.
Purpose:
- Confirm accurate voltage conversion
- Verify tap position
- Ensure correct output voltage
Polarity Test
Checks the relationship between primary and secondary windings.
Purpose:
- Confirm correct internal connection
- Ensure proper system installation
No-Load Loss and No-Load Current Test
The transformer is energized without load.
Measured:
- No-load loss
- Excitation current
Purpose:
✔ Verify core performance
✔ Confirm energy efficiency
✔ Check magnetic circuit quality
Load Loss and Impedance Test
The transformer is tested under short-circuit conditions.
Measured:
- Load loss
- Short-circuit impedance
Purpose:
- Verify winding performance
- Confirm efficiency
- Ensure thermal design reliability
5. Insulation Performance Tests
Insulation Resistance Test
Insulation resistance is measured between:
- HV winding and ground
- LV winding and ground
- HV and LV windings
Purpose:
✔ Verify insulation condition
✔ Prevent electrical breakdown
✔ Improve operating safety
Dielectric Withstand Test
High voltage withstand testing verifies insulation strength.
Purpose:
- Detect insulation defects
- Confirm electrical safety
- Ensure reliable operation under voltage stress
Induced Voltage Test
Checks internal winding insulation performance.
Purpose:
- Verify turn-to-turn insulation
- Improve long-term reliability
6. Oil Quality & Leakage Testing
For oil-immersed pole mounted transformers:
Transformer Oil Test
Inspection includes:
- Dielectric strength
- Moisture content
- Oil quality
- Insulation performance
Oil Leakage Test
The transformer tank is tested to ensure:
- No oil leakage
- Reliable sealing
- Long-term outdoor operation
7. Mechanical Structure Inspection
The transformer body is inspected before shipment.
Inspection items:
✔ Tank welding quality
✔ Surface coating condition
✔ Bushing installation
✔ Nameplate information
✔ Grounding connection
✔ Lifting structure
8. Final Performance Inspection
Before shipment, engineers perform final verification.
Includes:
- Appearance inspection
- Dimension check
- Accessory confirmation
- Electrical parameter verification
- Test data review
Factory Routine Test Summary
| Test Item |
Purpose |
| Winding Resistance Test |
Verify winding quality |
| Voltage Ratio Test |
Confirm voltage accuracy |
| Polarity Test |
Verify winding connection |
| No-Load Loss Test |
Check core efficiency |
| Load Loss Test |
Evaluate operating performance |
| Impedance Test |
Confirm transformer characteristics |
| Insulation Resistance Test |
Verify insulation reliability |
| Dielectric Test |
Check insulation strength |
| Oil Test |
Ensure insulation performance |
| Leakage Test |
Verify tank sealing |
| Final Inspection |
Confirm shipment quality |
Test Documents Provided
Each 75kVA Conventional Type Single Phase Pole Mounted Transformer can be supplied with:
- Factory Test Report
- Routine Test Certificate
- Quality Inspection Record
- Product Datasheet
- Technical Drawings
- Installation Instructions
Quality Assurance
Every transformer is tested before delivery to ensure:
✔ Reliable outdoor operation
✔ Stable voltage performance
✔ High insulation strength
✔ Low energy loss
✔ Long service life
Strict manufacturer testing ensures that each 75kVA Single Phase Pole Mounted Transformer is ready for safe and reliable operation in utility distribution networks, rural electrification projects, residential power systems, and agricultural applications worldwide.
The 75kVA Conventional Type Single Phase Pole Mounted Transformer undergoes complete routine testing before shipment to verify electrical performance, insulation reliability, and manufacturing quality.
Each transformer is individually tested according to international standards, including IEC 60076, IEEE C57, and ANSI C57 requirements, ensuring safe operation and long-term reliability in overhead distribution networks.
1. Winding Resistance Test
The DC resistance of the high-voltage and low-voltage windings is measured using precision testing equipment.
Test Purpose:
- Verify winding manufacturing quality
- Confirm conductor connection reliability
- Check resistance balance
- Detect poor connections or production defects
Inspection Items:
✔ HV winding resistance
✔ LV winding resistance
✔ Temperature-corrected resistance values
2. Voltage Ratio Test
The transformer turns ratio is measured to confirm accurate voltage transformation.
Test Purpose:
- Verify primary-to-secondary voltage ratio
- Confirm tap position accuracy
- Ensure correct output voltage
Inspection Items:
✔ Rated voltage ratio
✔ Tap position ratio deviation
✔ Phase relationship verification
3. Polarity Test
The transformer polarity is checked to confirm correct internal winding connections.
Test Purpose:
- Ensure proper installation compatibility
- Verify winding connection direction
- Prevent connection errors during operation
4. No-Load Loss and No-Load Current Test
The transformer is energized at rated voltage without any load connected.
Measured Parameters:
- No-load loss
- No-load current
Purpose:
✔ Evaluate core quality
✔ Verify silicon steel performance
✔ Confirm transformer energy efficiency
✔ Check magnetic circuit design
5. Load Loss and Impedance Voltage Test
The transformer is tested under short-circuit conditions to measure load performance.
Measured Parameters:
- Load loss
- Short-circuit impedance
Purpose:
- Verify winding performance
- Confirm copper loss values
- Ensure compliance with design requirements
- Evaluate operating efficiency
6. Insulation Resistance Test
Insulation resistance is measured between different electrical parts.
Testing Points:
- HV winding to ground
- LV winding to ground
- HV winding to LV winding
Purpose:
✔ Verify insulation condition
✔ Prevent insulation breakdown
✔ Ensure safe electrical operation
7. Dielectric Withstand Test
High-voltage withstand testing is performed to check the insulation system.
Test Purpose:
- Verify insulation strength
- Detect internal insulation defects
- Confirm transformer safety under electrical stress
8. Induced Voltage Test
The transformer is subjected to increased frequency voltage to verify internal insulation performance.
Purpose:
- Check turn-to-turn insulation
- Verify winding insulation quality
- Improve operational reliability
9. Transformer Oil Testing
For oil-immersed pole mounted transformers, insulating oil quality is inspected.
Test Items:
- Dielectric breakdown voltage
- Moisture content
- Oil condition
- Insulation performance
Purpose:
✔ Ensure effective insulation
✔ Improve heat dissipation
✔ Prevent internal discharge failures
10. Oil Leakage and Sealing Test
The transformer tank is tested for sealing performance.
Inspection Includes:
- Tank weld inspection
- Oil leakage inspection
- Bushing sealing check
- Pressure holding test
Purpose:
- Ensure leak-free operation
- Maintain insulation oil quality
- Improve service life
11. Appearance and Assembly Inspection
Before shipment, the completed transformer receives a final inspection.
Inspection Items:
✔ Transformer dimensions
✔ Nameplate information
✔ Paint and coating quality
✔ Bushing installation
✔ Grounding terminals
✔ Accessories installation
Routine Testing Summary
| Routine Test |
Purpose |
| Winding Resistance Test |
Verify winding quality |
| Voltage Ratio Test |
Confirm accurate voltage conversion |
| Polarity Test |
Check winding connection |
| No-Load Loss Test |
Evaluate core performance |
| No-Load Current Test |
Check excitation characteristics |
| Load Loss Test |
Verify operating efficiency |
| Impedance Test |
Confirm electrical characteristics |
| Insulation Resistance Test |
Verify insulation reliability |
| Dielectric Test |
Confirm insulation strength |
| Oil Test |
Ensure insulation and cooling performance |
| Leakage Test |
Verify tank sealing |
| Final Inspection |
Confirm shipment readiness |
Factory Test Documentation
After completing routine tests, customers can receive:
- Factory Routine Test Report
- Electrical Test Certificate
- Quality Inspection Report
- Product Datasheet
- Technical Drawings
- Installation Manual
Quality Assurance
Every 75kVA Conventional Type Single Phase Pole Mounted Transformer is fully tested before delivery to ensure:
✔ Reliable power distribution performance
✔ Safe outdoor operation
✔ Low energy losses
✔ Strong insulation capability
✔ Long service life
Strict routine testing guarantees that each transformer is ready for dependable operation in utility networks, rural electrification systems, residential distribution, and agricultural power supply projects worldwide.
The 75kVA Conventional Type Single Phase Pole Mounted Transformer is a reliable oil-immersed distribution transformer designed for overhead power distribution networks. It is mainly used to step down medium voltage electricity from utility distribution lines to low voltage power for residential, commercial, agricultural, and small industrial users.
With its compact structure, easy installation, low maintenance requirements, and excellent outdoor durability, it is widely used in utility distribution systems, rural electrification projects, and decentralized power supply applications.
1. Residential Power Distribution
The 75kVA single phase pole mounted transformer is commonly used for supplying electricity to residential areas through overhead distribution lines.
Typical Applications:
- Rural residential communities
- Suburban housing areas
- Villages and small towns
- Single-family homes
- Residential development projects
Advantages:
✔ Stable household power supply
✔ Suitable for overhead distribution systems
✔ Compact installation design
✔ Easy maintenance and inspection
✔ Cost-effective power distribution solution
2. Rural Electrification Projects
The transformer is widely used in rural grid expansion and electrification programs where reliable and economical power supply is required.
Typical Applications:
- Remote villages
- Agricultural communities
- Rural public facilities
- Off-grid extension projects
Benefits:
✔ Simple pole installation
✔ Reduced infrastructure costs
✔ Reliable operation in outdoor environments
✔ Suitable for long-distance distribution networks
3. Agricultural Power Supply
The 75kVA pole mounted transformer provides dependable electricity for agricultural operations.
Typical Applications:
- Farms
- Irrigation systems
- Greenhouses
- Livestock facilities
- Agricultural processing equipment
Advantages:
✔ Supports motor loads and agricultural equipment
✔ Reliable operation under outdoor conditions
✔ Low maintenance requirements
✔ Suitable for distributed rural power systems
4. Small Commercial Applications
The transformer can supply power for small commercial facilities requiring stable low-voltage electricity.
Typical Applications:
- Small shops
- Offices
- Restaurants
- Service stations
- Local business facilities
Benefits:
✔ Reliable voltage supply
✔ Easy installation
✔ Suitable for independent power distribution
5. Small Industrial Facilities
The 75kVA transformer is suitable for light industrial and workshop applications.
Typical Applications:
- Small factories
- Workshops
- Warehouses
- Repair facilities
- Processing plants
Advantages:
✔ Continuous power supply capability
✔ Strong outdoor adaptability
✔ Flexible voltage configuration
✔ Reduced installation cost
6. Utility Distribution Networks
Utility companies commonly deploy conventional pole mounted transformers in overhead distribution systems.
Typical Applications:
- Distribution feeders
- Local grid networks
- Community power supply
- Utility expansion projects
Benefits:
✔ Proven utility technology
✔ Easy replacement and maintenance
✔ Compatible with overhead line systems
✔ Long operational life
7. Renewable Energy & Distributed Generation
The transformer can be integrated into small renewable energy distribution systems.
Typical Applications:
- Solar distributed generation
- Rural solar power systems
- Microgrid projects
- Small renewable energy installations
Advantages:
✔ Reliable grid connection
✔ Suitable for outdoor installation
✔ Flexible voltage options
✔ Supports decentralized power supply
8. Public Infrastructure Projects
The transformer can provide power for small-scale public facilities.
Typical Applications:
- Schools
- Clinics
- Community centers
- Water pumping stations
- Municipal facilities
Benefits:
✔ Reliable electricity access
✔ Simple installation
✔ Suitable for remote locations
Typical Application Environments
The 75kVA Conventional Type Single Phase Pole Mounted Transformer is suitable for:
✔ Rural areas
✔ Suburban communities
✔ Agricultural regions
✔ Outdoor utility networks
✔ Tropical climates
✔ Desert regions
✔ High-temperature environments
Recommended Markets
| Region |
Typical Applications |
| Africa |
Rural electrification, villages, agricultural power supply |
| Middle East |
Remote communities, farms, infrastructure projects |
| Southeast Asia |
Rural grids, residential areas, commercial users |
| Latin America |
Utility distribution, residential electrification |
| North America |
Overhead residential distribution systems |
Why Choose 75kVA Single Phase Pole Mounted Transformer?
✔ Reliable overhead distribution solution
✔ Compact and easy installation
✔ Low operating and maintenance cost
✔ High outdoor durability
✔ Flexible voltage customization
✔ Suitable for utility and private power networks
The 75kVA Conventional Type Single Phase Pole Mounted Transformer provides a dependable and economical power distribution solution for residential communities, rural electrification, agricultural applications, and utility networks worldwide.
1. What is a 75kVA Conventional Type Single Phase Pole Mounted Transformer?
The 75kVA Conventional Type Single Phase Pole Mounted Transformer is an oil-immersed distribution transformer designed for overhead electrical distribution systems. It reduces medium voltage electricity from utility distribution lines to low voltage power suitable for residential, agricultural, commercial, and small industrial applications.
It is commonly installed on utility poles and provides a reliable, economical solution for decentralized power distribution.
2. What are the main applications of a 75kVA pole mounted transformer?
The transformer is widely used in:
- Residential communities
- Rural electrification projects
- Agricultural power supply
- Small commercial buildings
- Workshops and small factories
- Utility distribution networks
- Solar distributed power systems
- Remote area electrification
3. What voltage levels are available for the 75kVA transformer?
The transformer can be customized according to different country and utility requirements.
High Voltage Side:
- 2.4kV
- 4.16kV
- 7.2kV
- 11kV
- 12.47kV
- 13.2kV
- 13.8kV
- 15kV
- 20kV
- 24.9kV
- 33kV
- 34.5kV
Low Voltage Side:
- 120/240V
- 220/380V
- 230/400V
- 240/480V
Customized voltage configurations are available.
4. Is the 75kVA transformer suitable for outdoor installation?
Yes. The transformer is designed for outdoor operation and can withstand various environmental conditions.
Features include:
- Weather-resistant tank design
- Outdoor anti-corrosion coating
- Oil insulation and cooling system
- UV-resistant surface protection
- Reliable sealing structure
It can be customized for:
- Desert environments
- Tropical climates
- Coastal areas
- High humidity regions
5. What type of cooling system does this transformer use?
The standard cooling method is:
ONAN (Oil Natural Air Natural)
This means:
- Transformer oil transfers heat from internal components
- External air cools the tank surface naturally
- No additional cooling equipment is required
This design provides reliable and low-maintenance operation.
6. What winding materials are available?
Customers can choose:
Copper Winding
Advantages:
- Higher conductivity
- Lower electrical losses
- Better overload capability
- Longer service life
Aluminum Winding
Advantages:
- Cost-effective
- Lightweight
- Suitable for standard distribution applications
7. What standards does the transformer comply with?
The transformer can be manufactured according to:
- IEC 60076 Power Transformer Standard
- IEEE C57 Distribution Transformer Standard
- ANSI C57.12 Utility Transformer Standard
- Customer-specific utility standards
8. What tests are performed before delivery?
Every transformer undergoes strict factory testing.
Routine tests include:
✔ Winding resistance test
✔ Voltage ratio test
✔ Polarity test
✔ No-load loss test
✔ No-load current test
✔ Load loss test
✔ Impedance test
✔ Insulation resistance test
✔ Dielectric withstand test
✔ Transformer oil test
✔ Leakage test
✔ Final appearance inspection
A complete factory test report can be provided.
9. Can the transformer be customized?
Yes. OEM customization is available.
Customization options include:
- HV/LV voltage
- Frequency (50Hz/60Hz)
- Copper or aluminum winding
- Core material
- Transformer oil type
- Tank design
- Protection accessories
- Mounting structure
- Customer logo and nameplate
10. What protection accessories are available?
Optional accessories include:
- Fuse cutout
- Lightning arrester
- Surge protection device
- Low voltage circuit breaker
- Oil level indicator
- Oil temperature indicator
- Pressure relief device
- Smart monitoring system
11. What is the expected service life of a 75kVA pole mounted transformer?
With proper installation and maintenance, the transformer can typically provide:
30 years or more of reliable service life
Service life depends on:
- Operating load
- Environmental conditions
- Maintenance practices
- Installation quality
12. How is the transformer transported?
The transformer is prepared for safe international shipment.
Transportation methods:
- Sea freight
- Land transportation
- Railway transportation
Packing includes:
- Waterproof protection
- Anti-impact protection
- Secure fixing
- Export standard packaging
13. What documents are provided with the transformer?
Customers can receive:
- Product datasheet
- Technical specifications
- Factory test report
- Quality certificate
- Installation manual
- Operation instructions
- Packing list
- Certificate of origin
14. What is the difference between conventional type and CSP pole mounted transformers?
Conventional Type Transformer:
- Basic and economical design
- Requires external protection devices
- Commonly used in utility distribution systems
CSP (Completely Self-Protected) Transformer:
- Includes built-in protection functions
- Contains internal protection components
- Provides additional safety features
The conventional type is preferred where external protection systems are already available.
15. Why choose a 75kVA Single Phase Pole Mounted Transformer?
Main advantages:
✔ Reliable overhead distribution solution
✔ Compact and easy installation
✔ Low maintenance requirements
✔ High outdoor durability
✔ Flexible voltage options
✔ Cost-effective power supply solution
✔ Suitable for global utility applications
The 75kVA Conventional Type Single Phase Pole Mounted Transformer is a proven solution for reliable electricity distribution, providing efficient and durable power supply for residential, rural, agricultural, and utility projects worldwide.