{"id":1755,"date":"2026-08-14T11:49:22","date_gmt":"2026-08-14T03:49:22","guid":{"rendered":"https:\/\/www.zishengelectric.com\/?post_type=product&#038;p=1755"},"modified":"2026-11-10T15:29:21","modified_gmt":"2026-11-10T07:29:21","slug":"110kv-115kv-power-transformer","status":"publish","type":"product","link":"https:\/\/www.zishengelectric.com\/es\/product\/110kv-115kv-power-transformer","title":{"rendered":"110kV 115kV Power Transformer"},"content":{"rendered":"<h2>110kV 115kV Power Transformer for Grid and Substation Duty<\/h2>\n<p>The 110kV \/ 115kV Power Transformer is a three-phase, high-voltage oil-immersed transformer designed for power transmission, substation and large-scale industrial applications.<\/p>\n<p>It is used to step up or step down electrical energy between high-voltage transmission networks and medium-voltage systems. Rated capacity, voltage ratio, impedance, vector group, tap range, cooling system and insulation level are selected for the project requirements and installation conditions.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto;\" title=\"Oil-Immersed Power Transformer in a Substation\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-substation-overview-16x9-v2.jpg\" alt=\"Oil-immersed power transformer with radiators, conservator and high-voltage bushings in a substation\" width=\"1600\" height=\"900\" \/><\/figure>\n<h3>Core, Windings and Oil-Paper Insulation<\/h3>\n<p>The active assembly combines the magnetic core, insulated windings, leads and supporting structures inside an oil-filled tank. Core material, copper or aluminum windings, insulation clearances and mechanical bracing are selected for the agreed loss, dielectric, thermal and short-circuit requirements. Final material grades and construction details follow the approved design.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto;\" title=\"Transformer Coil and Internal Assembly\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-core-assembly-16x9-v2.jpg\" alt=\"Technicians working on an insulated transformer coil beside completed oil-immersed transformers\" width=\"1600\" height=\"900\" \/><\/figure>\n<h3>Tank, Bushings and Cooling Equipment<\/h3>\n<p>Bushings provide the external winding connections. Radiators or cooler banks transfer heat from the insulating liquid to air. ONAN uses natural oil and air circulation; ONAF adds forced air; OFAF uses forced oil and air; ODAF uses directed oil circulation with forced air. The cooling-stage ratings, fans, pumps and control supply are defined in the accessory and cooling schedule.<\/p>\n<p>Conservator or sealed-tank arrangements, tap-changing equipment, oil valves, temperature indication and protective devices are coordinated with the tank design and installation. A Buchholz relay applies to suitable conservator arrangements and should not be presented as universal equipment on every tank type. Online monitoring, remote communication and additional sensors are options unless included in the purchase specification.<\/p>\n<h2>Product Cases<\/h2>\n<h3>Case 1: 110\/33kV Substation Capacity Expansion<\/h3>\n<p>The project requirement is an additional three-phase transformer bay supplying mixed distribution feeders and industrial motor loads. Daily load variation, motor starting and a restricted outage window make voltage regulation, existing-bus interfaces and installation sequencing central to selection.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto;\" title=\"Outdoor Utility Substation Layout\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-utility-substation-16x9-v2.jpg\" alt=\"Aerial view of an outdoor substation surrounded by green countryside\" width=\"1600\" height=\"900\" \/><\/figure>\n<p>Selection starts with the feeder demand study, future load allowance and the required operating arrangement. If parallel operation is intended, the existing transformer ratio, vector group, impedance, tap positions and protection settings must be reviewed together. The chosen MVA and cooling stages must meet the continuous and contingency duties without treating the capacity range as a default order rating.<\/p>\n<table>\n<thead>\n<tr>\n<th>Project interface<\/th>\n<th>Configuration and acceptance requirement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Electrical connection<\/td>\n<td>110\/33kV, three-phase; MVA, vector group, impedance and neutral arrangement defined by the approved system study.<\/td>\n<\/tr>\n<tr>\n<td>Existing substation<\/td>\n<td>Check foundation load, bushing position, busbar clearances, oil containment and crane access against the final general arrangement.<\/td>\n<\/tr>\n<tr>\n<td>Voltage control<\/td>\n<td>Coordinate tap operation and parallel control with the existing transformer and utility voltage policy.<\/td>\n<\/tr>\n<tr>\n<td>Release and energization<\/td>\n<td>Review serial-numbered test reports, approved drawings, alarm\/trip functions and receiving records before the agreed site commissioning checks.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto;\" title=\"Oil-Immersed Power Transformer in a Substation\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-substation-overview-16x9-v2.jpg\" alt=\"Oil-immersed power transformer with radiators, conservator and high-voltage bushings in a substation\" width=\"1600\" height=\"900\" \/><\/figure>\n<p>The key engineering issue is compatibility with the operating substation. Approval should resolve busbar alignment and parallel-load-sharing requirements before manufacture; receiving inspection and installation records then provide the link between factory release and site energization.<\/p>\n<h3>Case 2: 115\/34.5kV Solar and Battery Storage Grid Connection<\/h3>\n<p>The grid connection links a 34.5kV collector system to a 115kV network. Solar generation, battery charging and discharging, auxiliary demand and reactive-power support create several operating conditions rather than one constant export load.<\/p>\n<figure><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto;\" title=\"Solar Farm and Grid Connection Works\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-solar-farm-aerial-16x9-v2.jpg\" alt=\"Aerial view of a solar farm and its electrical substation under construction\" width=\"1600\" height=\"900\" \/><\/figure>\n<p>The transformer is selected from the complete three-phase apparent-power envelope. For balanced operation, S = \u221a(P\u00b2 + Q\u00b2), using consistent MW, MVAr and MVA units. Solar and battery nameplate MW values alone do not establish the required transformer MVA; simultaneous operating limits, inverter harmonics, ambient conditions and the utility interconnection study also matter.<\/p>\n<table>\n<thead>\n<tr>\n<th>Project interface<\/th>\n<th>Configuration and acceptance requirement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Voltage arrangement<\/td>\n<td>115\/34.5kV; confirm winding connection, neutral earthing, highest equipment voltage and insulation coordination.<\/td>\n<\/tr>\n<tr>\n<td>Operating envelope<\/td>\n<td>Evaluate export, charging\/import, reactive support and permitted simultaneous operation against the agreed continuous and thermal duty.<\/td>\n<\/tr>\n<tr>\n<td>Control coordination<\/td>\n<td>Coordinate OLTC settings with plant voltage control; define command priority, remote signals and operating limits.<\/td>\n<\/tr>\n<tr>\n<td>Factory evidence<\/td>\n<td>Agree the dielectric schedule, loss and impedance acceptance, cooling-control checks and traceable report package.<\/td>\n<\/tr>\n<tr>\n<td>Site constraints<\/td>\n<td>Confirm access road limits, crane position, detached accessory installation, oil handling and containment before delivery.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure><img loading=\"lazy\" decoding=\"async\" style=\"width: 100%; height: auto;\" title=\"Power Transformer Factory Test Setup\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-factory-test-16x9-v2.jpg\" alt=\"Power transformer connected to electrical test equipment in a high-voltage test hall\" width=\"1600\" height=\"900\" \/><\/figure>\n<p>The key engineering issue is coordination between the transformer, inverter plant controller and grid requirements. Acceptance focuses on the approved operating envelope, protection and control interfaces, and the documented transition from factory test release to site checks.<\/p>\n<h3>Related Product Range<\/h3>\n<p>For projects with a different grid voltage, compare the <a href=\"https:\/\/www.zishengelectric.com\/es\/product\/220kv-230kv-power-transformer\/\">220kV \/ 230kV power transformer<\/a> range. Select the nominal voltage and insulation requirements from the utility specification.<\/p>","protected":false},"excerpt":{"rendered":"<p>The 110kV \/ 115kV Power Transformer is a three-phase, high-voltage oil-immersed transformer designed for power transmission, substation and large-scale industrial applications.<\/p>\n<p>It is used to step up or step down electrical energy between high-voltage transmission networks and medium-voltage systems. Rated capacity, voltage ratio, impedance, vector group, tap range, cooling system and insulation level are selected for the project requirements and installation conditions.<\/p>\n<p>&nbsp;<\/p>","protected":false},"featured_media":2700,"template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[],"product_cat":[71],"product_tag":[],"class_list":["post-1755","product","type-product","status-publish","has-post-thumbnail","product_cat-oil-immersed-transformer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.zishengelectric.com\/es\/wp-json\/wp\/v2\/product\/1755","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zishengelectric.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.zishengelectric.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zishengelectric.com\/es\/wp-json\/wp\/v2\/media\/2700"}],"wp:attachment":[{"href":"https:\/\/www.zishengelectric.com\/es\/wp-json\/wp\/v2\/media?parent=1755"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/es\/wp-json\/wp\/v2\/product_brand?post=1755"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/es\/wp-json\/wp\/v2\/product_cat?post=1755"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/es\/wp-json\/wp\/v2\/product_tag?post=1755"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}