{"id":1872,"date":"2026-09-01T15:37:21","date_gmt":"2026-09-01T07:37:21","guid":{"rendered":"https:\/\/www.zishengelectric.com\/?post_type=product&#038;p=1872"},"modified":"2026-11-06T18:22:57","modified_gmt":"2026-11-06T10:22:57","slug":"132kv-138kv-power-transformer","status":"publish","type":"product","link":"https:\/\/www.zishengelectric.com\/ru\/product\/132kv-138kv-power-transformer","title":{"rendered":"138kV \/ 140kV \/ 150kV Three-Phase Oil-Immersed Power Transformer"},"content":{"rendered":"<p>The 138kV \/ 140kV \/ 150kV Three-Phase Oil-Immersed Power Transformer is a high-voltage oil-immersed transformer designed for utility substations, power generation plants, industrial power networks, renewable energy projects, and large-scale transmission and distribution systems.<\/p>\n<figure style=\"margin: 24px 0; width: 100%;\"><img loading=\"lazy\" decoding=\"async\" style=\"display: block; width: 100%; max-width: 1600px; height: auto; margin: 0 auto;\" title=\"Oil-Immersed Power Transformer in a Substation\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-substation-overview-16x9-v2.jpg\" alt=\"Oil-immersed power transformer with radiators, conservator and high-voltage bushings in a substation\" width=\"1600\" height=\"900\" \/><\/figure>\n<p>It is engineered to provide reliable voltage transformation between high-voltage transmission networks and medium- or low-voltage distribution systems. Depending on the project, the transformer can be configured as a step-up or step-down transformer with customized capacity, voltage ratio, vector group, impedance, cooling system, tap changer and protection system.<\/p>\n<h3>Voltage Configuration and Grid Interface<\/h3>\n<p>The HV winding is specified for 138kV, 140kV or 150kV. Select the MV\/LV winding voltage from the project bus arrangement, with 11kV, 13.8kV, 33kV, 34.5kV or a customized voltage as applicable. Confirm the complete winding-voltage schedule in the approved datasheet.<\/p>\n<p>Rated capacity can be designed from several MVA to tens or hundreds of MVA, depending on the application and grid requirements.<\/p>\n<hr \/>\n<h2>Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Typical Specification<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Product Type<\/td>\n<td>High Voltage Oil-Immersed Power Transformer<\/td>\n<\/tr>\n<tr>\n<td>Rated Capacity<\/td>\n<td>Customized, typically 10\u2013200+ MVA<\/td>\n<\/tr>\n<tr>\n<td>Primary Voltage<\/td>\n<td>138kV \/ 140kV \/ 150kV<\/td>\n<\/tr>\n<tr>\n<td>Secondary Voltage<\/td>\n<td>11kV \/ 13.8kV \/ 33kV \/ 34.5kV \/ Customized<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>50Hz \/ 60Hz<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>Three Phase<\/td>\n<\/tr>\n<tr>\n<td>Cooling Method<\/td>\n<td>ONAN \/ ONAF \/ OFAF \/ OFWF<\/td>\n<\/tr>\n<tr>\n<td>Winding Material<\/td>\n<td>Copper \/ Aluminum<\/td>\n<\/tr>\n<tr>\n<td>Tap Changer<\/td>\n<td>OLTC \/ Off-Circuit Tap Changer<\/td>\n<\/tr>\n<tr>\n<td>Vector Group<\/td>\n<td>Dyn11 \/ YNd11 \/ YNyn0 \/ Customized<\/td>\n<\/tr>\n<tr>\n<td>Neutral<\/td>\n<td>Solid \/ Resistance \/ Reactance Grounded, as required<\/td>\n<\/tr>\n<tr>\n<td>Insulation Medium<\/td>\n<td>Mineral Oil \/ Ester Fluid<\/td>\n<\/tr>\n<tr>\n<td>Oil Preservation<\/td>\n<td>Conservator \/ Sealed Type<\/td>\n<\/tr>\n<tr>\n<td>Core Material<\/td>\n<td>High-Grade Grain-Oriented Electrical Steel<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>50 \/ 60Hz<\/td>\n<\/tr>\n<tr>\n<td>Installation<\/td>\n<td>Outdoor \/ Indoor<\/td>\n<\/tr>\n<tr>\n<td>Insulation Level<\/td>\n<td>According to system voltage and applicable standard<\/td>\n<\/tr>\n<tr>\n<td>Standards<\/td>\n<td>IEC 60076 Series \/ IEEE \/ ANSI or Customized<\/td>\n<\/tr>\n<tr>\n<td>Accessories<\/td>\n<td>Buchholz Relay, PRD, OTI, WTI, MOG, etc.<\/td>\n<\/tr>\n<tr>\n<td>Monitoring<\/td>\n<td>Optional Online Monitoring System<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note: Final electrical parameters must be determined from the customer&#8217;s technical specification, grid code, utility requirements and transformer design.<\/p>\n<hr \/>\n<h2>Main Features<\/h2>\n<h3>High-Voltage Transmission Capability<\/h3>\n<p>Designed for 138kV, 140kV and 150kV transmission and sub-transmission networks, with insulation systems engineered for high electrical stress and long-term reliability.<\/p>\n<h3>High Efficiency<\/h3>\n<p>Optimized magnetic core and winding design reduces:<\/p>\n<ul>\n<li>No-load losses<\/li>\n<li>Load losses<\/li>\n<li>Operating costs<\/li>\n<li>Temperature rise<\/li>\n<\/ul>\n<h3>Strong Short-Circuit Capability<\/h3>\n<p>The winding structure is mechanically reinforced to withstand the electromagnetic forces generated during short-circuit conditions.<\/p>\n<h3>Reliable Insulation System<\/h3>\n<p>The insulation system is designed around:<\/p>\n<p>Oil + Paper \/ Pressboard + Insulation Components + Controlled Electric Field Distribution<\/p>\n<p>High-quality insulation materials and optimized field grading improve dielectric reliability.<\/p>\n<h3>Flexible Cooling<\/h3>\n<p>Different cooling configurations can be selected according to transformer capacity and operating conditions:<\/p>\n<p>ONAN \u2192 ONAF \u2192 OFAF \/ OFWF<\/p>\n<h3>OLTC Voltage Regulation<\/h3>\n<p>An On-Load Tap Changer (OLTC) can be installed to regulate the output voltage while the transformer remains energized.<\/p>\n<p>This is particularly useful for utility substations where grid voltage fluctuates during operation.<\/p>\n<hr \/>\n<h2>Transformer Construction<\/h2>\n<h2>1. Magnetic Core<\/h2>\n<p>The core is manufactured from high-quality grain-oriented electrical steel.<\/p>\n<p>Typical design features include:<\/p>\n<ul>\n<li>Step-lap core construction<\/li>\n<li>Low magnetic flux density<\/li>\n<li>Reduced no-load losses<\/li>\n<li>Low excitation current<\/li>\n<li>Reduced operating noise<\/li>\n<li>High mechanical stability<\/li>\n<\/ul>\n<p>The core is carefully clamped to maintain mechanical integrity during transportation and operation.<\/p>\n<hr \/>\n<h2>2. High-Voltage Winding<\/h2>\n<p>The HV winding is designed specifically for high-voltage electrical stress.<\/p>\n<p>The design considers:<\/p>\n<ul>\n<li>Voltage distribution<\/li>\n<li>Inter-turn insulation<\/li>\n<li>Inter-layer insulation<\/li>\n<li>Axial and radial forces<\/li>\n<li>Short-circuit withstand capability<\/li>\n<li>Impulse voltage distribution<\/li>\n<\/ul>\n<p>Depending on the capacity and voltage class, different winding structures can be selected.<\/p>\n<hr \/>\n<h2>3. Low-Voltage \/ Medium-Voltage Winding<\/h2>\n<p>The secondary winding can be configured for common substation voltages such as:<\/p>\n<p>11kV \u2022 13.8kV \u2022 33kV \u2022 34.5kV<\/p>\n<p>Customized voltage ratios are also available.<\/p>\n<hr \/>\n<h2>4. Transformer Tank<\/h2>\n<p>The transformer tank is manufactured from high-strength steel and designed to withstand:<\/p>\n<ul>\n<li>Vacuum conditions<\/li>\n<li>Pressure variations<\/li>\n<li>Transportation vibration<\/li>\n<li>Thermal expansion<\/li>\n<li>Electromagnetic forces<\/li>\n<\/ul>\n<p>The tank can be subjected to leakage and pressure testing before shipment.<\/p>\n<hr \/>\n<h2>Tap Changer<\/h2>\n<p>For 138kV \/ 140kV \/ 150kV power transformers, an OLTC can be provided for automatic voltage regulation.<\/p>\n<p>Typical options include:<\/p>\n<ul>\n<li>\u00b110%<\/li>\n<li>\u00b112.5%<\/li>\n<li>\u00b115%<\/li>\n<\/ul>\n<p>The actual tap range and number of positions are customized according to the grid specification.<\/p>\n<p>The OLTC can be integrated with:<\/p>\n<ul>\n<li>Automatic Voltage Regulator<\/li>\n<li>AVR Control Panel<\/li>\n<li>Remote Control<\/li>\n<li>SCADA<\/li>\n<li>Digital Monitoring System<\/li>\n<\/ul>\n<hr \/>\n<h2>Cooling System<\/h2>\n<p>The cooling system is selected according to transformer capacity and project requirements.<\/p>\n<h3>ONAN<\/h3>\n<p>Oil Natural Air Natural<\/p>\n<p>Suitable for transformers where natural oil and air circulation can provide sufficient cooling.<\/p>\n<h3>ONAF<\/h3>\n<p>Oil Natural Air Forced<\/p>\n<p>Cooling fans increase heat dissipation and improve the transformer&#8217;s load capability.<\/p>\n<h3>OFAF<\/h3>\n<p>Oil Forced Air Forced<\/p>\n<p>Oil pumps and cooling fans are used for larger-capacity transformers.<\/p>\n<h3>OFWF<\/h3>\n<p>Oil Forced Water Forced<\/p>\n<p>Suitable for specific high-capacity or special installation environments.<\/p>\n<hr \/>\n<h2>Protection &amp; Accessories<\/h2>\n<p>A complete 138kV \/ 140kV \/ 150kV transformer can be equipped with comprehensive protection and monitoring devices.<\/p>\n<h3>Standard \/ Common Accessories<\/h3>\n<ul>\n<li>Buchholz Relay<\/li>\n<li>Pressure Relief Device<\/li>\n<li>Oil Level Gauge<\/li>\n<li>Oil Temperature Indicator<\/li>\n<li>Winding Temperature Indicator<\/li>\n<li>Silica Gel Breather<\/li>\n<li>Conservator Tank<\/li>\n<li>Drain Valve<\/li>\n<li>Sampling Valve<\/li>\n<li>Earthing Terminals<\/li>\n<li>Lifting Lugs<\/li>\n<li>Jacking Pads<\/li>\n<\/ul>\n<h3>Optional Monitoring<\/h3>\n<ul>\n<li>Online dissolved gas analysis<\/li>\n<li>Moisture monitoring<\/li>\n<li>Bushing monitoring<\/li>\n<li>Fiber-optic temperature monitoring<\/li>\n<li>OLTC monitoring<\/li>\n<li>Remote data acquisition<\/li>\n<li>RS485 \/ Modbus<\/li>\n<li>IEC 61850 communication<\/li>\n<li>SCADA integration<\/li>\n<\/ul>\n<hr \/>\n<h2>Bushings<\/h2>\n<p>The 138kV \/ 140kV \/ 150kV transformer can be equipped with high-voltage condenser bushings suitable for the specified system voltage and insulation level.<\/p>\n<p>Configuration can be customized according to:<\/p>\n<ul>\n<li>Rated voltage<\/li>\n<li>Rated current<\/li>\n<li>BIL \/ LI level<\/li>\n<li>Creepage distance<\/li>\n<li>Pollution level<\/li>\n<li>Altitude<\/li>\n<li>Installation environment<\/li>\n<li>Customer-approved drawings<\/li>\n<\/ul>\n<p>For coastal, desert or heavily polluted environments, an increased creepage distance can be considered.<\/p>\n<hr \/>\n<h2>Insulating Oil<\/h2>\n<p>The transformer can use:<\/p>\n<ul>\n<li>Mineral transformer oil<\/li>\n<li>Natural ester fluid<\/li>\n<li>Synthetic ester fluid<\/li>\n<\/ul>\n<p>The oil insulation system is selected according to the project requirements and applicable standards.<\/p>\n<p>Before filling, the insulating fluid can undergo appropriate treatment such as:<\/p>\n<p>Filtration \u2192 Vacuum Treatment \u2192 Moisture Removal \u2192 Dielectric Strength Verification \u2192 Filling<\/p>\n<hr \/>\n<h2>Customization Options<\/h2>\n<p>The 138kV \/ 140kV \/ 150kV Three-Phase Oil-Immersed Power Transformer can be engineered according to EPC, utility and grid requirements.<\/p>\n<h3>Electrical<\/h3>\n<ul>\n<li>138kV \/ 140kV \/ 150kV HV<\/li>\n<li>11kV \/ 13.8kV \/ 33kV \/ 34.5kV LV\/MV<\/li>\n<li>Customized MVA capacity<\/li>\n<li>50Hz \/ 60Hz<\/li>\n<li>Customized vector group<\/li>\n<li>Customized impedance<\/li>\n<li>Customized insulation level<\/li>\n<li>OLTC<\/li>\n<li>Off-circuit tap changer<\/li>\n<\/ul>\n<h3>Mechanical<\/h3>\n<ul>\n<li>Conservator type<\/li>\n<li>Sealed tank<\/li>\n<li>Radiator configuration<\/li>\n<li>Detachable radiator<\/li>\n<li>Customized enclosure<\/li>\n<li>Customized terminal arrangement<\/li>\n<li>Customized dimensions<\/li>\n<\/ul>\n<h3>Environmental<\/h3>\n<ul>\n<li>High-altitude design<\/li>\n<li>Tropical design<\/li>\n<li>Desert design<\/li>\n<li>Coastal \/ salt-spray protection<\/li>\n<li>High-humidity design<\/li>\n<li>High-temperature design<\/li>\n<li>Seismic requirements<\/li>\n<li>Anti-corrosion coating<\/li>\n<\/ul>\n<hr \/>\n<h2>Voltage Options and Project Configuration<\/h2>\n<p>Specify 138kV, 140kV or 150kV as the required HV winding rating. These are separate design options, not interchangeable nameplate ratings. The network nominal voltage, highest voltage for equipment, insulation coordination and MV\/LV bus arrangement determine the final winding-voltage and dielectric requirements.<\/p>\n<p>Confirm the MVA rating at each cooling stage, frequency, vector group, impedance, tap range, grounding and protection interfaces in the approved technical schedule.<\/p>\n<h2>Selection and RFQ Requirements<\/h2>\n<p>Specify the transformer from the system study and load or generation profile. Nominal network voltage alone does not define the required insulation level, MVA rating or winding arrangement.<\/p>\n<ul>\n<li>Electrical duty: rated MVA at each cooling stage, winding voltages, frequency, step-up or step-down service, load profile, power factor and future expansion.<\/li>\n<li>System interfaces: two or three windings or autotransformer arrangement, vector group, neutral grounding, fault level, short-circuit impedance, parallel operation and any tertiary loading.<\/li>\n<li>Insulation and regulation: highest voltage for equipment, impulse and AC withstand requirements, neutral insulation, creepage distance, tap range and control philosophy.<\/li>\n<li>Site and cooling: ambient temperature, altitude, pollution, seismic duty, installation clearances, sound limits, auxiliary supply and cooling-water conditions where water cooling is specified.<\/li>\n<li>Procurement scope: conductor and insulating fluid requirements, guaranteed losses, bushings, protection and monitoring, termination drawings, delivery route, inspection plan and document schedule.<\/li>\n<\/ul>\n<p>For renewable generation, include the required reactive-power operating range, harmonic data and grid-code duty. For motor-driven industrial loads, provide starting studies and voltage-dip limits. Confirm losses and impedance on the same rating and reference-temperature basis when comparing offers.<\/p>\n<h2>Product Cases<\/h2>\n<h3>Case 1: Mining Substation Upgrade<\/h3>\n<p>The mining substation supplies three-phase crushers, conveyors, water pumps and process auxiliaries. Large motor starts overlap with continuous process demand, so the transformer review uses the simultaneous kVA profile, starting method, available fault level and permitted voltage dip. The upgrade also needs to fit the existing bay and planned shutdown window.<\/p>\n<figure style=\"margin: 24px 0; width: 100%;\"><img loading=\"lazy\" decoding=\"async\" style=\"display: block; width: 100%; max-width: 1600px; height: auto; margin: 0 auto;\" title=\"Mine Substation and Distribution Interfaces\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-mine-substation-16x9-v2.jpg\" alt=\"Aerial view of transformers, switchgear and control buildings in a fenced mine substation\" width=\"1600\" height=\"900\" \/><\/figure>\n<table>\n<thead>\n<tr>\n<th>Engineering item<\/th>\n<th>Case requirement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Transformer duty<\/td>\n<td>Three-phase oil-immersed step-down service within the 138kV \/ 140kV \/ 150kV product range<\/td>\n<\/tr>\n<tr>\n<td>Voltage interface<\/td>\n<td>HV winding selected from 138kV, 140kV or 150kV; MV winding voltage, final ratings and terminal arrangement confirmed in the approved design<\/td>\n<\/tr>\n<tr>\n<td>Rating and impedance<\/td>\n<td>Selected from the load and starting studies; impedance checked against fault duty and voltage regulation<\/td>\n<\/tr>\n<tr>\n<td>Site constraints<\/td>\n<td>Existing foundation and bushing positions, access route, crane setup, pollution and maintenance clearances<\/td>\n<\/tr>\n<tr>\n<td>Configuration<\/td>\n<td>Project-approved winding arrangement, grounding, cooling stages and tap-control scope<\/td>\n<\/tr>\n<tr>\n<td>Acceptance<\/td>\n<td>Approved drawings, traceable test reports, control and protection interface checks, transport and arrival records<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Where the new unit operates in parallel with an existing transformer, the engineering review checks voltage ratio, vector group, polarity, tap positions and impedance characteristics before connection. Where units remain separate, the bus-transfer and protection design still needs review. The accessory and control schedules identify alarm, trip, cooling and SCADA interfaces for the site team.<\/p>\n<figure style=\"margin: 24px 0; width: 100%;\"><img loading=\"lazy\" decoding=\"async\" style=\"display: block; width: 100%; max-width: 1600px; height: auto; margin: 0 auto;\" title=\"Oil-Immersed Power Transformer in a Substation\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-substation-overview-16x9-v2.jpg\" alt=\"Oil-immersed power transformer with radiators, conservator and high-voltage bushings in a substation\" width=\"1600\" height=\"900\" \/><\/figure>\n<h3>Case 2: Solar Collector Substation Grid Connection<\/h3>\n<p>The solar plant exports three-phase power from its collection network to a 138kV grid connection. Selection uses the permitted active and reactive power envelope, auxiliary demand and harmonic study rather than the panel DC rating alone. Available substation land, terminal clearances and access for future radiator or bushing maintenance define the physical arrangement.<\/p>\n<figure style=\"margin: 24px 0; width: 100%;\"><img loading=\"lazy\" decoding=\"async\" style=\"display: block; width: 100%; max-width: 1600px; height: auto; margin: 0 auto;\" title=\"Solar Farm and Grid Connection Works\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-solar-farm-aerial-16x9-v2.jpg\" alt=\"Aerial view of a solar farm and its electrical substation under construction\" width=\"1600\" height=\"900\" \/><\/figure>\n<table>\n<thead>\n<tr>\n<th>Engineering item<\/th>\n<th>Case requirement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Transformer duty<\/td>\n<td>Three-phase oil-immersed grid step-up service<\/td>\n<\/tr>\n<tr>\n<td>Grid interface<\/td>\n<td>138kV connection with utility-approved insulation and grounding<\/td>\n<\/tr>\n<tr>\n<td>Capacity basis<\/td>\n<td>MVA over the required active\/reactive operating envelope and site temperature conditions<\/td>\n<\/tr>\n<tr>\n<td>Electrical coordination<\/td>\n<td>Collector voltage, vector group, harmonic duty, neutral arrangement and impedance confirmed by the connection study<\/td>\n<\/tr>\n<tr>\n<td>Regulation and cooling<\/td>\n<td>Agreed tap range, voltage-control responsibility, cooling ratings and auxiliary supply<\/td>\n<\/tr>\n<tr>\n<td>Acceptance documents<\/td>\n<td>Approved technical schedule, dielectric test plan, witnessed FAT records where specified, control drawings and shipping release<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The plant controller and tap regulator need an agreed operating philosophy to avoid conflicting voltage commands. The purchaser and manufacturer review protection CT requirements, neutral earthing, inrush and overfluxing considerations, and the effects of harmonic currents. Shipment release follows the approved inspection plan; site acceptance also verifies reassembled components, fluid condition and pre-energization checks.<\/p>\n<figure style=\"margin: 24px 0; width: 100%;\"><img loading=\"lazy\" decoding=\"async\" style=\"display: block; width: 100%; max-width: 1600px; height: auto; margin: 0 auto;\" title=\"Solar Plant High-Voltage Grid Connection\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/138-150kv-solar-grid-substation-16x9-v2.jpg\" alt=\"Aerial view of a fenced high-voltage substation beside extensive solar panel arrays\" width=\"1600\" height=\"900\" \/><\/figure>\n<h2>Related Products and Engineering Guidance<\/h2>\n<p>Browse the <a href=\"https:\/\/www.zishengelectric.com\/ru\/product-category\/oil-immersed-transformer\/\">oil-immersed transformer range<\/a>, or compare the <a href=\"https:\/\/www.zishengelectric.com\/ru\/product\/110kv-115kv-power-transformer\/\">110kV \/ 115kV power transformer<\/a> for projects at a different network voltage. For procurement and handover, read our <a href=\"https:\/\/www.zishengelectric.com\/ru\/transformer-inspection-test-plan-epc.html\/\">transformer inspection and test plan guide<\/a> and <a href=\"https:\/\/www.zishengelectric.com\/ru\/transformer-site-acceptance-test-checklist-epc.html\/\">transformer site acceptance checklist<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p><strong data-start=\"31\" data-end=\"66\">138kV \/ 140kV \/ 150kV Three-Phase Oil-Immersed Power Transformer<\/strong> designed for utility substations, power plants, renewable energy and large industrial projects. <strong data-start=\"163\" data-end=\"226\" data-is-only-node=\"\">Custom MVA capacity, voltage ratio, OLTC and cooling system<\/strong> available. Engineered to IEC\/IEEE\/ANSI standards with comprehensive factory testing and EPC project support.<\/p>","protected":false},"featured_media":1873,"template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[],"product_cat":[71],"product_tag":[],"class_list":["post-1872","product","type-product","status-publish","has-post-thumbnail","product_cat-oil-immersed-transformer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product\/1872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/media\/1873"}],"wp:attachment":[{"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/media?parent=1872"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product_brand?post=1872"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product_cat?post=1872"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product_tag?post=1872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}