{"id":2063,"date":"2026-09-17T15:12:53","date_gmt":"2026-09-17T07:12:53","guid":{"rendered":"https:\/\/www.zishengelectric.com\/?post_type=product&#038;p=2063"},"modified":"2026-11-06T14:48:44","modified_gmt":"2026-11-06T06:48:44","slug":"50kva-conventional-type-single-phase-pole-mounted-transformer","status":"publish","type":"product","link":"https:\/\/www.zishengelectric.com\/ru\/product\/50kva-conventional-type-single-phase-pole-mounted-transformer","title":{"rendered":"50kVA Conventional Type Single Phase Pole Mounted Transformer"},"content":{"rendered":"<p>The 50kVA conventional single-phase pole-mounted transformer is designed to step medium-voltage distribution power down to a stable low-voltage supply. It is commonly installed on utility poles for residential communities, rural electrification, farms, small commercial facilities and municipal distribution networks.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/50kva-single-phase-pole-mounted-transformer-installation.png\" alt=\"Cylindrical single-phase transformer mounted on an outdoor utility pole\" title=\"Single-Phase Pole-Mounted Transformer\" width=\"1672\" height=\"941\" style=\"display:block;max-width:100%;height:auto;\" \/><\/p>\n<p>Unlike a CSP transformer, the conventional type normally relies on externally installed primary fuses, surge arresters and secondary protection. Primary voltage, secondary voltage, winding material, insulating fluid, bushings and mounting accessories can be customized for different utility standards.<\/p>\n<h2>Main Technical Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Parameter<\/th>\n<th>Standard Configuration \/ Options<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Rated Capacity<\/td>\n<td>50kVA<\/td>\n<\/tr>\n<tr>\n<td>Transformer Type<\/td>\n<td>Conventional single-phase pole-mounted transformer<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>Single phase<\/td>\n<\/tr>\n<tr>\n<td>Primary Voltage<\/td>\n<td>2.4kV\u201334.5kV or customized<\/td>\n<\/tr>\n<tr>\n<td>Secondary Voltage<\/td>\n<td>120\/240V, 240\/480V, 277V or customized<\/td>\n<\/tr>\n<tr>\n<td>Rated Frequency<\/td>\n<td>50Hz or 60Hz<\/td>\n<\/tr>\n<tr>\n<td>Cooling Method<\/td>\n<td>ONAN<\/td>\n<\/tr>\n<tr>\n<td>Winding Material<\/td>\n<td>Copper or aluminum<\/td>\n<\/tr>\n<tr>\n<td>Core Material<\/td>\n<td>Cold-rolled grain-oriented silicon steel<\/td>\n<\/tr>\n<tr>\n<td>Insulating Fluid<\/td>\n<td>Mineral oil or natural ester fluid<\/td>\n<\/tr>\n<tr>\n<td>Tapping Range<\/td>\n<td>Typically \u00b12 \u00d7 2.5% or customized<\/td>\n<\/tr>\n<tr>\n<td>Temperature Rise<\/td>\n<td>55\u00b0C, 65\u00b0C or project-specific<\/td>\n<\/tr>\n<tr>\n<td>Tank Construction<\/td>\n<td>Sealed cylindrical steel tank<\/td>\n<\/tr>\n<tr>\n<td>Primary Bushing<\/td>\n<td>One- or two-bushing configuration<\/td>\n<\/tr>\n<tr>\n<td>Secondary Bushings<\/td>\n<td>Three- or four-bushing arrangement<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>Single-pole mounting brackets<\/td>\n<\/tr>\n<tr>\n<td>Installation<\/td>\n<td>Outdoor<\/td>\n<\/tr>\n<tr>\n<td>Standard Altitude<\/td>\n<td>Up to 1,000m; high-altitude design available<\/td>\n<\/tr>\n<tr>\n<td>Ambient Temperature<\/td>\n<td>According to IEEE, CSA, IEC or project requirements<\/td>\n<\/tr>\n<tr>\n<td>Applicable Standards<\/td>\n<td>IEEE C57, ANSI, CSA, IEC 60076 or specified utility standard<\/td>\n<\/tr>\n<tr>\n<td>Polarity<\/td>\n<td>Additive or subtractive according to the approved design<\/td>\n<\/tr>\n<tr>\n<td>Finish<\/td>\n<td>Weather-resistant coating; custom colour available<\/td>\n<\/tr>\n<tr>\n<td>Expected Service Life<\/td>\n<td>Approximately 25\u201330 years with correct loading and maintenance<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Typical Voltage Configurations<\/h2>\n<p>Common primary and secondary voltage combinations include:<\/p>\n<ul>\n<li>7.2kV\/120\u2013240V<\/li>\n<li>7.62kV\/120\u2013240V<\/li>\n<li>7.97kV\/120\u2013240V<\/li>\n<li>12.47kV\/120\u2013240V<\/li>\n<li>13.2kV\/120\u2013240V<\/li>\n<li>13.8kV\/120\u2013240V<\/li>\n<li>14.4kV\/120\u2013240V<\/li>\n<li>24.94kV\/120\u2013240V<\/li>\n<li>34.5kV\/120\u2013240V<\/li>\n<li>13.2kV\/240\u2013480V<\/li>\n<li>13.8kV\/240\u2013480V<\/li>\n<li>Other project-specific voltage ratios<\/li>\n<\/ul>\n<p>The primary voltage should be specified as both the system voltage and the actual phase-to-neutral voltage applied to the transformer.<\/p>\n<h2>Typical Rated Current<\/h2>\n<table>\n<thead>\n<tr>\n<th>Voltage Side<\/th>\n<th>Example Voltage<\/th>\n<th>Approximate Rated Current<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Primary<\/td>\n<td>7.2kV<\/td>\n<td>6.94A<\/td>\n<\/tr>\n<tr>\n<td>Primary<\/td>\n<td>13.2kV<\/td>\n<td>3.79A<\/td>\n<\/tr>\n<tr>\n<td>Primary<\/td>\n<td>14.4kV<\/td>\n<td>3.47A<\/td>\n<\/tr>\n<tr>\n<td>Primary<\/td>\n<td>24.94kV<\/td>\n<td>2.00A<\/td>\n<\/tr>\n<tr>\n<td>Secondary<\/td>\n<td>240V<\/td>\n<td>208.3A<\/td>\n<\/tr>\n<tr>\n<td>Secondary<\/td>\n<td>480V<\/td>\n<td>104.2A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Rated current values are calculated from the full 50kVA capacity and must be confirmed against the approved voltage configuration.<\/em><\/p>\n<h2>Key Product Features<\/h2>\n<h3>Compact Pole-Mounted Construction<\/h3>\n<p>The cylindrical tank and integrated mounting brackets provide a compact installation footprint. The transformer is suitable for overhead distribution systems where ground space is limited.<\/p>\n<h3>Low-Loss Magnetic Core<\/h3>\n<p>The core uses grain-oriented electrical steel with optimized joints to reduce no-load loss, excitation current, operating noise and vibration.<\/p>\n<h3>Reliable Winding System<\/h3>\n<p>Copper or aluminum conductors can be supplied. The winding structure is mechanically reinforced to withstand short-circuit forces, voltage fluctuations and normal transportation stresses.<\/p>\n<h3>Oil Insulation and Natural Cooling<\/h3>\n<p>The core and coil assembly is immersed in insulating fluid, which provides electrical insulation and transfers heat to the tank wall. ONAN cooling requires no external fans or pumps.<\/p>\n<h3>Sealed Steel Tank<\/h3>\n<p>The sealed tank limits contact between the insulating fluid and outside air, helping reduce moisture ingress, oxidation and maintenance requirements.<\/p>\n<h3>Outdoor Durability<\/h3>\n<p>The transformer can be supplied with:<\/p>\n<ul>\n<li>UV-resistant exterior coating<\/li>\n<li>Corrosion-resistant hardware<\/li>\n<li>Stainless-steel nameplate<\/li>\n<li>Sealed bushings and gaskets<\/li>\n<li>Coastal or high-humidity protection<\/li>\n<li>Bird guards and wildlife-protection covers<\/li>\n<\/ul>\n<h2>Conventional Type vs. CSP Type<\/h2>\n<table>\n<thead>\n<tr>\n<th>Feature<\/th>\n<th>Conventional Type<\/th>\n<th>CSP Type<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Primary Fuse<\/td>\n<td>Normally installed externally<\/td>\n<td>Usually integrated<\/td>\n<\/tr>\n<tr>\n<td>Surge Arrester<\/td>\n<td>Normally installed externally<\/td>\n<td>May be factory-mounted<\/td>\n<\/tr>\n<tr>\n<td>Secondary Breaker<\/td>\n<td>Not normally included<\/td>\n<td>Commonly integrated<\/td>\n<\/tr>\n<tr>\n<td>Protection Coordination<\/td>\n<td>Designed by utility or project engineer<\/td>\n<td>Partially integrated into transformer<\/td>\n<\/tr>\n<tr>\n<td>Maintenance<\/td>\n<td>Simple transformer construction<\/td>\n<td>More integrated components<\/td>\n<\/tr>\n<tr>\n<td>Application<\/td>\n<td>Flexible utility protection schemes<\/td>\n<td>Standardized distribution networks<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Main Components<\/h2>\n<p>A typical 50kVA conventional pole-mounted transformer includes:<\/p>\n<ul>\n<li>Magnetic core<\/li>\n<li>Primary winding<\/li>\n<li>Secondary winding<\/li>\n<li>Insulating fluid<\/li>\n<li>Cylindrical steel tank<\/li>\n<li>Tank cover and sealing gasket<\/li>\n<li>High-voltage bushing or bushings<\/li>\n<li>Low-voltage bushings<\/li>\n<li>Grounding terminals<\/li>\n<li>Pole-mounting brackets<\/li>\n<li>Lifting lugs<\/li>\n<li>Pressure-relief device<\/li>\n<li>Oil filling plug<\/li>\n<li>Drain or sampling valve, when specified<\/li>\n<li>Stainless-steel nameplate<\/li>\n<\/ul>\n<h2>Optional Accessories<\/h2>\n<p>Available accessories include:<\/p>\n<ul>\n<li>External surge arrester<\/li>\n<li>Primary fuse cutout<\/li>\n<li>Lightning arrester mounting bracket<\/li>\n<li>Pressure-relief device<\/li>\n<li>Oil-level plug or indicator<\/li>\n<li>Drain and sampling valve<\/li>\n<li>Grounding strap<\/li>\n<li>Wildlife guards<\/li>\n<li>Secondary terminal covers<\/li>\n<li>Tank ground connectors<\/li>\n<li>Copper or tin-plated terminals<\/li>\n<li>Dual-voltage switch<\/li>\n<li>Series-multiple switch<\/li>\n<li>Off-circuit tap changer<\/li>\n<li>Natural ester insulating fluid<\/li>\n<li>Stainless-steel hardware<\/li>\n<li>Special pole-mounting brackets<\/li>\n<\/ul>\n<h2>Customization Options<\/h2>\n<table>\n<thead>\n<tr>\n<th>Customizable Item<\/th>\n<th>Available Options<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Primary Voltage<\/td>\n<td>2.4kV\u201334.5kV<\/td>\n<\/tr>\n<tr>\n<td>Secondary Voltage<\/td>\n<td>120\/240V, 240\/480V, 277V or customized<\/td>\n<\/tr>\n<tr>\n<td>Frequency<\/td>\n<td>50Hz or 60Hz<\/td>\n<\/tr>\n<tr>\n<td>Winding Material<\/td>\n<td>Copper or aluminum<\/td>\n<\/tr>\n<tr>\n<td>Primary Connection<\/td>\n<td>Single-bushing or dual-bushing<\/td>\n<\/tr>\n<tr>\n<td>Secondary Connection<\/td>\n<td>Centre-tapped or project-specific<\/td>\n<\/tr>\n<tr>\n<td>Tap Range<\/td>\n<td>Standard or customized off-circuit taps<\/td>\n<\/tr>\n<tr>\n<td>Insulating Fluid<\/td>\n<td>Mineral oil or natural ester<\/td>\n<\/tr>\n<tr>\n<td>Temperature Rise<\/td>\n<td>55\u00b0C or 65\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Efficiency<\/td>\n<td>Utility- or market-specific efficiency level<\/td>\n<\/tr>\n<tr>\n<td>BIL<\/td>\n<td>Selected according to the voltage class<\/td>\n<\/tr>\n<tr>\n<td>Tank Material<\/td>\n<td>Carbon steel or stainless steel<\/td>\n<\/tr>\n<tr>\n<td>Paint Colour<\/td>\n<td>Light grey, green or custom colour<\/td>\n<\/tr>\n<tr>\n<td>Corrosion Protection<\/td>\n<td>Standard, coastal or heavy-duty system<\/td>\n<\/tr>\n<tr>\n<td>Mounting<\/td>\n<td>Standard or customized pole brackets<\/td>\n<\/tr>\n<tr>\n<td>Accessories<\/td>\n<td>Arresters, fuse brackets, wildlife guards and terminal covers<\/td>\n<\/tr>\n<tr>\n<td>Standards<\/td>\n<td>IEEE\/ANSI, CSA, IEC or customer specification<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Construction, Connections and Cooling<\/h2>\n<p>The oil-immersed assembly comprises a magnetic core, insulated windings, internal leads, a cylindrical tank, high- and low-voltage bushings, mounting brackets, lifting provisions and an identification nameplate. Confirm the winding conductor, core material, insulating fluid, tank finish and accessory schedule in the approved technical offer.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/pole-mounted-transformer-core-internal-reference.jpg\" alt=\"Insulated connections and low-voltage terminals inside a cylindrical transformer tank\" title=\"Transformer Internal Connections\" width=\"948\" height=\"533\" style=\"display:block;max-width:100%;width:100%;height:auto;\" loading=\"lazy\" \/><\/p>\n<p>In an ONAN configuration, the insulating liquid circulates naturally and transfers heat through the tank to the surrounding air. The cooling designation, permissible temperature rise and site conditions must match the selected design. Bushings and terminals provide electrical connections; they are not lifting or cargo-restraint points.<\/p>\n<h3>Bushings and Outdoor Interfaces<\/h3>\n<p>Check primary and secondary terminal arrangements, clearances, grounding connections and bracket dimensions against the utility drawing. Pressure-relief devices, tap changers and other accessories are supplied only as identified in the agreed scope.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/pole-mounted-transformer-hv-bushing-reference.jpg\" alt=\"Technician fitting a high-voltage bushing to a cylindrical transformer tank cover\" title=\"High-Voltage Bushing Assembly\" width=\"948\" height=\"533\" style=\"display:block;max-width:100%;width:100%;height:auto;\" loading=\"lazy\" \/><\/p>\n<h2>Selection and Quotation Requirements<\/h2>\n<p>For a 50 kVA conventional single-phase pole-mounted transformer, begin with the utility connection and the simultaneous load schedule. The 50 kVA rating describes apparent power; it does not by itself establish motor-starting capability or the number of customers that can be supplied.<\/p>\n<ul>\n<li>Electrical system: primary voltage at the actual connection point, secondary voltage and wire arrangement, frequency, grounding and required polarity.<\/li>\n<li>Load duty: simultaneous kW or kVA, power factor, largest motor, starting current or starting method, load imbalance and expected growth.<\/li>\n<li>Design requirements: applicable utility specification, insulation level, tapping range, guaranteed losses, impedance and required winding conductor or insulating fluid.<\/li>\n<li>Site interfaces: ambient temperature, altitude, pollution or coastal exposure, pole and bracket dimensions, terminal positions and low-voltage cable route.<\/li>\n<li>Supply scope: external fuse cutout, surge arrester, secondary protection, mounting hardware, quantity, destination, inspection requirements and required delivery documents.<\/li>\n<\/ul>\n<p>A single-bushing primary requires a compatible grounded system and an approved return path. A two-bushing arrangement must also match the utility connection. Off-circuit taps must only be operated with the transformer isolated and de-energized.<\/p>\n<h2>Product Cases<\/h2>\n<h3>Case 1: Residential and Community Overhead Supply<\/h3>\n<p>The supply requirement combines household lighting, refrigeration, small appliances and community facilities connected to an overhead distribution line. Demand diversity, evening peaks and the distance to the furthest service point are the main selection considerations. The 50 kVA unit is assessed against the simultaneous apparent load and the utility&#8217;s permitted voltage drop.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/rural-village-power-distribution.jpg\" alt=\"Aerial view of a rural village surrounded by hills and farmland\" title=\"Rural Community Distribution\" width=\"948\" height=\"533\" style=\"display:block;max-width:100%;width:100%;height:auto;\" loading=\"lazy\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Engineering item<\/th>\n<th>Case requirement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Transformer<\/td>\n<td>50 kVA conventional single-phase pole-mounted design<\/td>\n<\/tr>\n<tr>\n<td>Connection<\/td>\n<td>Utility-approved primary voltage, secondary service arrangement, frequency and grounding<\/td>\n<\/tr>\n<tr>\n<td>Load assessment<\/td>\n<td>Coincident household and community demand, power factor and growth allowance<\/td>\n<\/tr>\n<tr>\n<td>Site limits<\/td>\n<td>Pole loading, bracket compatibility, public clearances and secondary feeder length<\/td>\n<\/tr>\n<tr>\n<td>Protection<\/td>\n<td>Coordinated external primary protection, surge protection and downstream devices<\/td>\n<\/tr>\n<tr>\n<td>Acceptance documents<\/td>\n<td>Approved drawing, connection diagram, nameplate, traceable routine test report and packing list<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Where a center-tapped secondary is ordered, the service design distributes loads between the two legs and checks neutral loading. Pole strength and mounting details require approval before installation; a compact tank does not establish the suitability of an existing pole. Acceptance checks verify ratio, polarity, terminal identification and the approved protection interfaces.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/residential-single-phase-pole-transformer-canada.jpg\" alt=\"Single cylindrical transformer on a wooden pole serving an overhead distribution line\" title=\"Residential Overhead Distribution\" width=\"948\" height=\"533\" style=\"display:block;max-width:100%;width:100%;height:auto;\" loading=\"lazy\" \/><\/p>\n<h3>Case 2: Farm Irrigation and Agricultural Buildings<\/h3>\n<p>The farm supply combines compatible single-phase water pumping, ventilation, lighting and control equipment. Irrigation and ventilation can operate together during warm periods, while long cable runs increase the risk of starting voltage drop. The load schedule therefore records electrical input current, power factor, operating overlap and the largest motor&#8217;s starting method.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/agricultural-irrigation-power-supply.jpg\" alt=\"Aerial view of irrigated agricultural fields and farm access tracks\" title=\"Agricultural Irrigation Fields\" width=\"948\" height=\"533\" style=\"display:block;max-width:100%;width:100%;height:auto;\" loading=\"lazy\" \/><\/p>\n<table>\n<thead>\n<tr>\n<th>Engineering item<\/th>\n<th>Case requirement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Transformer<\/td>\n<td>50 kVA conventional single-phase pole-mounted design<\/td>\n<\/tr>\n<tr>\n<td>Connected equipment<\/td>\n<td>Single-phase motors and auxiliary loads compatible with the approved secondary voltage<\/td>\n<\/tr>\n<tr>\n<td>Selection basis<\/td>\n<td>Simultaneous kVA, motor starting current, permitted voltage dip and future demand<\/td>\n<\/tr>\n<tr>\n<td>Pole location<\/td>\n<td>Utility access, structural capacity, maintenance clearance and a practical secondary cable route<\/td>\n<\/tr>\n<tr>\n<td>Configuration<\/td>\n<td>Confirmed ratio, frequency, tapping arrangement, fluid, mounting and external protection scope<\/td>\n<\/tr>\n<tr>\n<td>Acceptance<\/td>\n<td>Approved load and connection schedules, routine test records, accessory check and arrival inspection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The motor review separates mechanical output from electrical input and checks whether another motor can start while the irrigation pump is running. Three-phase pumps cannot connect directly to this single-phase secondary. The final cable and protection design must address starting duty, short-circuit conditions and selective operation, rather than relying only on the transformer&#8217;s 50 kVA rating.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.zishengelectric.com\/wp-content\/uploads\/2026\/11\/Pole-Location-and-Low-Voltage-Distribution.jpg\" alt=\"Cylindrical transformer mounted on a pole beside a farm track and overhead lines\" title=\"Farm Pole and Distribution Lines\" width=\"948\" height=\"533\" style=\"display:block;max-width:100%;width:100%;height:auto;\" loading=\"lazy\" \/><\/p>\n<h2>Related Products and Selection Guidance<\/h2>\n<p>Compare the <a href=\"https:\/\/www.zishengelectric.com\/ru\/product\/75kva-conventional-type-single-phase-pole-mounted-transformer\/\">75 kVA conventional pole-mounted transformer<\/a> where the assessed demand requires a larger rating, or browse the <a href=\"https:\/\/www.zishengelectric.com\/ru\/product-category\/pole-mounted-transformer\/\">pole-mounted transformer range<\/a>. For the inquiry checklist, read our <a href=\"https:\/\/www.zishengelectric.com\/ru\/distribution-transformer-selection-guide-how-to-choose-the-right-transformer.html\/\">distribution transformer selection guide<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>The 50 kVA conventional single-phase pole-mounted transformer supplies overhead distribution networks for suitable residential, rural, farm and small commercial loads. Confirm the voltage ratio, frequency, service connection, mounting and external protection requirements for the project.<\/p>","protected":false},"featured_media":2064,"template":"","meta":{"themepark_post_bcolor":"#f5f5f5","themepark_post_width":"1022px","themepark_post_img":"","themepark_post_img_po":"left","themepark_post_img_re":false,"themepark_post_img_cover":false,"themepark_post_img_fixed":false,"themepark_post_hide_title":false,"themepark_post_main_b":"","themepark_post_main_p":100,"themepark_paddingblock":false},"product_brand":[],"product_cat":[74],"product_tag":[],"class_list":["post-2063","product","type-product","status-publish","has-post-thumbnail","product_cat-pole-mounted-transformer","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product\/2063","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/media\/2064"}],"wp:attachment":[{"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/media?parent=2063"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product_brand?post=2063"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product_cat?post=2063"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.zishengelectric.com\/ru\/wp-json\/wp\/v2\/product_tag?post=2063"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}