The 1500kVA oil-immersed transformer provides safe, efficient and reliable power distribution for utility, industrial and renewable energy projects. Available with customized voltage ratios, copper or aluminum windings, and ONAN cooling, it is manufactured and tested in accordance with IEC or IEEE standards.

Catégorie :

Project Partners

Phone/WhatsApp: 8619131285373

Email: info@zishengtransformer.com
Factory Headquarters: No. 118, Jingyi Street, Economic Development Zone.

*
*
*

Project Stage

Submitting!
Submission successful!
Submission failed!
Incorrect email address!
Incorrect phone number!

The 1500kVA oil-immersed transformer is a three-phase distribution transformer designed to convert medium-voltage power into stable, usable voltage for industrial facilities, utility networks, renewable energy projects, commercial buildings and infrastructure systems.

The transformer uses high-quality silicon steel cores, copper or aluminum windings, transformer-grade insulating oil and a sealed corrugated tank. It can be customized according to the project voltage, frequency, vector group, impedance, installation environment and applicable IEC or IEEE standards.

Main Technical Specifications

Parameter Standard Configuration / Available Options
Rated Capacity 1500kVA / 1.5MVA
Transformer Type Oil-immersed distribution transformer
Phase Three phase
High Voltage 6kV, 10kV, 11kV, 13.8kV, 20kV, 22kV, 33kV or customized
Low Voltage 400V, 415V, 440V, 480V, 690V or customized
Frequency 50Hz or 60Hz
Cooling Method ONAN; ONAF available when required
Winding Material Copper or aluminum
Vector Group Dyn11, Dyn5, Yyn0, YNd1 or customized
Tap Changer Off-circuit tap changer or OLTC
Typical Tapping Range ±2 × 2.5%, ±5% or customized
Short-Circuit Impedance Typically 4.5%–6.5%, subject to project requirements
Insulation Medium Mineral insulating oil or natural/synthetic ester fluid
Core Material Cold-rolled grain-oriented silicon steel
Temperature Rise According to IEC/IEEE standard and project conditions
Ambient Temperature Typically −25°C to +40°C; high-temperature design available
Installation Outdoor or indoor
Altitude Up to 1,000m as standard; high-altitude design available
Tank Construction Hermetically sealed corrugated tank or conservator type
Protection Level Customized according to installation conditions
Standards IEC 60076, IEEE C57, ANSI, GB or project-specific standards
Service Life Designed for 25–30 years under proper operating conditions
Warranty According to the agreed technical and commercial contract

Final parameters are subject to the approved technical specification and transformer drawings.

Typical Voltage Configurations

The 1500kVA transformer can be engineered for different electrical systems, including:

  • 10kV/0.4kV
  • 11kV/0.415kV
  • 11kV/0.433kV
  • 13.8kV/0.480kV
  • 20kV/0.4kV
  • 22kV/0.415kV
  • 33kV/0.415kV
  • 33kV/0.480kV
  • Other customized voltage ratios

Key Product Features

High-Efficiency Magnetic Core

The transformer core is manufactured from high-permeability, cold-rolled grain-oriented silicon steel. Step-lap core construction can be used to reduce no-load loss, magnetizing current, vibration and operating noise.

Reliable Winding Structure

Copper or aluminum conductors are selected according to the required performance and project budget. The windings are mechanically reinforced to withstand short-circuit forces, voltage fluctuations and continuous industrial loading.

Effective Cooling System

The insulating oil transfers heat from the core and windings to the corrugated tank or radiator surfaces. ONAN cooling provides reliable heat dissipation without external cooling equipment. ONAF cooling can be supplied for special loading requirements.

Sealed Transformer Tank

A hermetically sealed tank prevents direct contact between transformer oil and outside air. This helps reduce moisture ingress, oil oxidation and routine maintenance requirements.

A conservator-type structure can also be supplied when required by the project specification.

Low Loss and Stable Operation

The core, windings and insulation system are optimized to provide:

  • Low no-load loss
  • Controlled load loss
  • Stable output voltage
  • Reduced operating temperature
  • Lower lifetime energy costs
  • Reliable continuous operation

Strong Environmental Adaptability

The transformer can be customized for demanding environments such as:

  • High ambient temperature
  • High altitude
  • Coastal salt-fog conditions
  • Desert and dusty locations
  • High-humidity regions
  • Mining and heavy industrial sites
  • Solar and wind power projects

Main Components

A typical 1500kVA oil-immersed transformer includes:

  • Magnetic core
  • High-voltage winding
  • Low-voltage winding
  • Insulating oil
  • Corrugated or radiator-type tank
  • High-voltage bushings
  • Low-voltage bushings
  • Off-circuit tap changer
  • Oil filling and drain valves
  • Earthing terminals
  • Lifting lugs
  • Jacking pads
  • Rating plate
  • Oil level indicator, where applicable
  • Pressure-relief device
  • Thermometer pocket
  • Bi-directional rollers or skid base

Optional Accessories

The following protection, monitoring and connection accessories are available:

  • Buchholz relay
  • Oil temperature indicator
  • Winding temperature indicator
  • Pressure-relief device
  • Magnetic oil level gauge
  • Sudden-pressure relay
  • Pressure vacuum gauge
  • Marshalling box
  • Cooling fans
  • Online temperature monitoring system
  • Oil leakage monitoring
  • Current transformers
  • Neutral current transformer
  • Cable boxes
  • Plug-in bushings
  • Surge arresters
  • HV and LV terminal enclosures
  • Remote alarm contacts
  • Stainless-steel hardware
  • Anti-condensation heater
  • OLTC control panel

Customization Options

Every 1500kVA transformer can be engineered around the actual project conditions.

Customization Item Available Options
Voltage Ratio Customized primary and secondary voltage
Frequency 50Hz or 60Hz
Conductor Copper or aluminum
Vector Group According to system configuration
Tap Regulation Off-circuit or on-load tap changer
Insulating Fluid Mineral oil, natural ester or synthetic ester
Tank Design Sealed corrugated tank or conservator type
Cooling ONAN or ONAF
Efficiency Level According to local regulations and tender requirements
Paint System C3, C4 or C5 corrosion protection
Enclosure Open terminals, cable box or protected terminal chamber
Noise Level Standard or low-noise design
Altitude Standard or high-altitude application
Ambient Conditions Tropical, desert, coastal or cold-climate design
Monitoring Local instruments or remote digital monitoring
Standards IEC, IEEE/ANSI, GB or customer-specified standard

Manufacturing Process

  1. Technical requirement review
  2. Electrical and mechanical design
  3. Customer drawing confirmation
  4. Core cutting and stacking
  5. HV and LV winding production
  6. Active-part assembly
  7. Drying and vacuum treatment
  8. Tank fabrication and surface treatment
  9. Vacuum oil filling
  10. Routine testing and inspection
  11. Packing and shipment preparation

Routine Factory Tests

Each transformer is tested before delivery. Routine tests can include:

  • Winding resistance measurement
  • Voltage-ratio measurement
  • Phase displacement and vector-group verification
  • Short-circuit impedance measurement
  • Load-loss measurement
  • No-load loss and no-load current measurement
  • Insulation resistance measurement
  • Applied voltage withstand test
  • Induced overvoltage withstand test
  • Transformer oil testing
  • Functional inspection of accessories
  • Tank sealing and oil-leakage inspection
  • Paint-thickness and appearance inspection

Optional Type and Special Tests

When required by the customer or project specification, additional tests can be arranged:

  • Temperature-rise test
  • Lightning impulse test
  • Sound-level measurement
  • Partial-discharge test
  • Zero-sequence impedance measurement
  • Harmonic measurement
  • Short-circuit withstand test
  • Oil dissolved-gas analysis
  • Capacitance and dissipation-factor measurement
  • FRA test
  • Witnessed Factory Acceptance Test
  • Independent third-party inspection

Product Applications

The 1500kVA oil-immersed transformer is suitable for:

  • Utility distribution networks
  • Industrial factories
  • Mining operations
  • Cement and steel plants
  • Oil and gas facilities
  • Water-treatment plants
  • Commercial buildings
  • Hospitals and airports
  • Data centers
  • Solar PV power plants
  • Wind power projects
  • Battery energy-storage systems
  • Municipal infrastructure
  • Industrial parks
  • Construction projects
  • EPC power-distribution projects

Installation Information Required

To prepare an accurate transformer design and quotation, please provide:

  • Required capacity: 1500kVA
  • Primary voltage
  • Secondary voltage
  • Frequency
  • Phase
  • Vector group
  • Required impedance
  • Winding material
  • Tap range and tap-changer type
  • Applicable standard
  • Installation altitude
  • Maximum and minimum ambient temperature
  • Indoor or outdoor installation
  • Cable or busbar connection
  • Required accessories
  • Efficiency or loss requirements
  • Quantity
  • Destination country

Packing and Shipping

The transformer is prepared for international transport with:

  • Moisture-resistant protective wrapping
  • Reinforced steel or wooden base
  • Protected bushings and accessories
  • Sealed accessory boxes
  • Export-standard marking
  • Technical documents and packing list
  • Container or breakbulk shipping arrangements

Depending on the transformer dimensions and shipping requirements, bushings, radiators and accessories may be removed and packed separately.

Frequently Asked Questions

Can the voltage ratio be customized?

Yes. The primary and secondary voltages can be designed according to the local electrical system and project requirements.

Is copper winding available?

Yes. Both copper and aluminum winding designs are available. Copper windings are often selected for projects requiring compact construction and stronger mechanical performance.

Can this transformer operate in hot climates?

Yes. The cooling system, insulation level, temperature rise and tank design can be adjusted for high-temperature environments.

Is the transformer suitable for solar projects?

Yes. It can be designed for solar PV, wind power and energy-storage applications, including special voltage ratios, harmonic considerations and bidirectional power flow.

Can it be used above 1,000 metres?

Yes. High-altitude transformers are available. The insulation clearances, cooling performance and rated capacity must be corrected according to the installation altitude.

Can you provide FAT documents?

Yes. The manufacturer can provide routine test reports, drawings, nameplate information, packing lists and other agreed FAT documents before shipment.

What information is needed for a quotation?

Please provide the voltage ratio, frequency, vector group, winding material, impedance, installation environment, required standard, accessories, quantity and destination country.

Parameter Specification
Rated Capacity 1500kVA / 1.5MVA
Transformer Type Oil-immersed distribution transformer
Phase Three phase
Rated Frequency 50Hz or 60Hz
Primary Voltage 6kV–35kV, customizable
Secondary Voltage 400V, 415V, 440V, 480V, 690V or customized
Vector Group Dyn11, Dyn5, Yyn0 or customized
Cooling Method ONAN; ONAF optional
Winding Material Copper or aluminum
Core Material Cold-rolled grain-oriented silicon steel
Tap Changer Off-circuit tap changer or OLTC
Tapping Range ±2 × 2.5%, ±5% or customized
Short-Circuit Impedance Typically 4.5%–6.5%
Insulating Fluid Mineral oil, natural ester or synthetic ester
Tank Design Hermetically sealed corrugated tank or conservator type
Temperature Rise According to IEC/IEEE requirements
Ambient Temperature Standard: −25°C to +40°C; special design available
Installation Altitude Up to 1,000m standard; high-altitude design available
Installation Indoor or outdoor
Insulation Class Class A or as specified
Noise Level According to IEC 60076-10 or project requirements
Protection Accessories Pressure-relief device, oil-level indicator and temperature indicator
Corrosion Protection C3, C4 or C5 paint system available
Applicable Standards IEC 60076, IEEE C57, ANSI, GB or specified standard
Expected Service Life 25–30 years under proper operating conditions

Voltage ratio, impedance, losses, dimensions, weight and accessories are finalized according to the approved project specification and technical drawings.

Customizable Item Available Options
Rated Capacity 1500kVA or customized according to load requirements
Primary Voltage 6kV, 10kV, 11kV, 13.8kV, 20kV, 22kV, 33kV, 35kV or customized
Secondary Voltage 400V, 415V, 440V, 480V, 690V or customized
Frequency 50Hz or 60Hz
Winding Material Copper or aluminum
Vector Group Dyn11, Dyn5, Yyn0, YNd1 or project-specific configuration
Tap Changer Off-circuit tap changer or on-load tap changer
Tapping Range ±2 × 2.5%, ±5% or customized
Short-Circuit Impedance Designed according to system and coordination requirements
Cooling Method ONAN or ONAF
Insulating Fluid Mineral oil, natural ester or synthetic ester
Tank Structure Hermetically sealed corrugated tank or conservator type
Efficiency Level Customized to local regulations and project loss requirements
Temperature Rise Standard or reduced temperature-rise design
Noise Level Standard or low-noise configuration
Installation Indoor or outdoor
Altitude Design Standard below 1,000m or customized for high-altitude locations
Climate Adaptation Tropical, desert, coastal, high-humidity or cold-climate design
Corrosion Protection C3, C4 or C5 paint system
Terminal Arrangement Porcelain bushings, plug-in bushings, cable boxes or busbar connections
Enclosure Open terminals, protective terminal covers or enclosed cable chambers
Protection Devices Buchholz relay, pressure-relief device and sudden-pressure relay
Monitoring Devices Oil and winding temperature indicators, oil-level gauge and remote contacts
Digital Monitoring Online temperature, oil-level and operating-status monitoring
Accessories Surge arresters, current transformers, marshalling box, rollers and cooling fans
Paint Colour RAL colour customized to project requirements
Applicable Standard IEC 60076, IEEE C57, ANSI, GB or customer-specified standard
Nameplate and Labels English, bilingual or customer-specified language
Documentation Drawings, test reports, manuals, data sheets and FAT documents
Inspection Customer-witnessed FAT or third-party inspection available
Packaging Container, breakbulk or seaworthy export packaging

All configurations can be engineered according to the project’s voltage system, installation environment, technical standard and operating conditions.

Each 1500kVA oil-immersed transformer is carefully inspected, protected and secured before shipment to ensure safe delivery to the project site.

Export Packaging

  • Transformer body fixed on a reinforced steel or wooden base
  • Bushings protected with impact-resistant covers
  • Accessories packed separately in waterproof wooden cases
  • Moisture-proof and dust-proof protective wrapping
  • Exposed metal parts treated with anti-rust protection
  • Valves, instruments and terminals securely sealed
  • Packing marks provided according to customer requirements
  • Seaworthy packaging suitable for long-distance transportation

Pre-Shipment Inspection

Before dispatch, the manufacturer will check:

  • Transformer appearance and paint finish
  • Oil level and sealing condition
  • Tank, valves and gasket connections
  • Bushings and terminal arrangement
  • Accessories and spare parts
  • Nameplate and warning labels
  • Packing list and shipping marks
  • Overall dimensions and transportation weight

Packing and loading photographs can be provided before shipment.

Transportation Methods

The transformer can be shipped by:

  • Standard or open-top container
  • Flat-rack container
  • Breakbulk vessel
  • Road transportation
  • Railway transportation
  • Multimodal international transport

The final shipping method is selected according to the transformer’s dimensions, total weight, destination and site-access conditions.

Shipping Documents

The standard documentation package can include:

  • Commercial invoice
  • Packing list
  • Bill of lading
  • Certificate of origin
  • Routine test report
  • Transformer drawings
  • Installation and operation manual
  • Product quality certificate
  • Warranty document
  • FAT records
  • Customs documents, when required

Installation guidance, remote technical support and spare parts can also be provided after delivery.

Each 1500kVA oil-immersed transformer undergoes comprehensive inspections and electrical tests during manufacturing and before shipment. Testing is performed according to IEC 60076, IEEE C57 or the customer’s specified standard.

Material and Component Inspection

  • Silicon-steel core material verification
  • Copper or aluminum conductor inspection
  • Insulation material quality inspection
  • Transformer oil quality verification
  • Bushing and tap-changer inspection
  • Tank material and welding inspection
  • Accessory model and certificate verification

Manufacturing Process Inspection

  • Core dimensions and stacking-quality inspection
  • Winding dimensions and conductor-joint inspection
  • Winding insulation and mechanical-strength inspection
  • Active-part assembly verification
  • Connection and vector-group inspection
  • Vacuum drying-process monitoring
  • Vacuum oil-filling inspection
  • Tank pressure and sealing inspection
  • Paint thickness and surface-finish inspection

Final Electrical Tests

Test Item Inspection Purpose
Winding Resistance Test Verifies conductor continuity and winding consistency
Voltage-Ratio Test Confirms the designed transformation ratio
Vector-Group Test Verifies phase displacement and terminal connections
Insulation Resistance Test Evaluates the condition of the insulation system
No-Load Loss Test Measures core loss at rated voltage
No-Load Current Test Checks core excitation performance
Load Loss Test Measures winding and stray losses
Impedance Voltage Test Confirms short-circuit impedance
Applied Voltage Test Verifies insulation strength to earth and other windings
Induced Voltage Test Checks inter-turn and inter-layer insulation
Oil Quality Test Confirms dielectric strength and oil condition
Functional Test Verifies tap changer, indicators, relays and accessories
Leakage Test Confirms the sealing performance of the tank and fittings

Optional Type and Special Tests

The following tests can be arranged according to project requirements:

  • Temperature-rise test
  • Lightning impulse test
  • Sound-level measurement
  • Partial-discharge test
  • Zero-sequence impedance measurement
  • Harmonic measurement
  • Capacitance and dissipation-factor test
  • Frequency response analysis
  • Transformer oil dissolved-gas analysis
  • Short-circuit withstand test
  • Third-party laboratory testing

Factory Acceptance Test

Customer representatives or an authorized third-party inspection company may witness the Factory Acceptance Test before shipment. The approved test report, nameplate details, drawings and inspection records can be included in the final documentation package.

All test procedures and acceptance criteria are confirmed according to the approved technical specification and applicable standard.

Every 1500kVA oil-immersed transformer is subjected to routine testing before shipment. Tests are conducted according to IEC 60076, IEEE C57 or the project’s approved technical specification.

Routine Test Purpose and Acceptance Criteria
Winding Resistance Measurement Confirms winding continuity, conductor connections and resistance balance between phases
Voltage-Ratio Measurement Verifies the designed voltage ratio at every tap position
Vector-Group Verification Confirms phase sequence, polarity and phase displacement
Short-Circuit Impedance Measurement Verifies that the transformer impedance meets the approved design value and tolerance
Load-Loss Measurement Measures winding and stray losses at the specified reference temperature
No-Load Loss Measurement Determines the core loss when rated voltage is applied
No-Load Current Measurement Checks the excitation current and magnetic-core condition
Insulation Resistance Test Evaluates insulation between HV, LV and earth
Applied Voltage Withstand Test Verifies the main insulation strength between windings and earth
Induced Overvoltage Test Checks the inter-turn, inter-layer and winding insulation
Tap-Changer Functional Test Confirms correct operation and connection at every tap position
Oil Dielectric Strength Test Verifies that the insulating oil meets the required dielectric performance
Tank Leakage Test Checks the sealing performance of the tank, valves, gaskets and welded joints
Accessory Functional Test Verifies temperature indicators, oil-level indicators, relays and alarm contacts
Visual and Dimensional Inspection Confirms dimensions, terminal arrangement, nameplate, paint finish and accessories
Earthing Continuity Test Verifies the reliability of the transformer grounding connections

Additional Routine Checks

  • Phase-to-phase resistance balance
  • Terminal marking verification
  • Bushing and connection inspection
  • Transformer oil-level inspection
  • Pressure-relief device inspection
  • Control wiring and marshalling-box verification
  • Cooling fan operation, when supplied
  • Alarm and trip contact verification
  • Paint-thickness inspection
  • Final cleanliness and appearance check

A complete routine test report can be supplied with the transformer before shipment. Type tests and special tests, such as temperature-rise, lightning-impulse, sound-level and partial-discharge tests, are available when required by the project specification.

The 1500kVA oil-immersed transformer is designed for medium-voltage power distribution in utility, industrial, commercial and renewable energy systems. It provides stable voltage conversion for continuous and demanding electrical loads.

Utility Distribution Networks

Suitable for urban and rural distribution systems, substations and grid-extension projects, converting medium voltage into low voltage for local power supply.

Industrial Facilities

Provides reliable power for:

  • Manufacturing plants
  • Industrial parks
  • Steel and cement factories
  • Chemical processing facilities
  • Food-processing plants
  • Warehouses and production workshops

Solar and Renewable Energy Projects

Can be customized for:

  • Solar photovoltaic power plants
  • Wind farms
  • Battery energy-storage systems
  • Hydropower projects
  • Renewable-energy substations

Special designs are available for harmonic loads, bidirectional power flow and high ambient temperatures.

Mining and Heavy Industry

Suitable for mines, crushing plants, conveyor systems, pumping stations and heavy industrial equipment. Reinforced structures and enhanced cooling can be provided for harsh operating environments.

Oil and Gas Projects

Applicable to oilfields, refineries, petrochemical plants, pumping stations and auxiliary power systems. Coastal and C5 anti-corrosion designs are available.

Commercial and Public Buildings

Provides power distribution for:

  • Shopping centres
  • Office complexes
  • Hotels
  • Hospitals
  • Airports
  • Universities
  • Data centres
  • Large residential developments

Infrastructure Projects

Suitable for municipal power systems, water-treatment plants, railway facilities, ports, construction projects and transportation infrastructure.

EPC and Customized Projects

The transformer can be engineered to match project-specific voltage ratios, impedance, vector groups, efficiency requirements, environmental conditions and protection systems.

Typical configurations include:

  • 10kV/0.4kV
  • 11kV/0.415kV
  • 13.8kV/0.48kV
  • 20kV/0.4kV
  • 22kV/0.415kV
  • 33kV/0.415kV

Other voltage combinations are available according to the project’s electrical system.

1. What is a 1500kVA oil-immersed transformer used for?

It is used to convert medium-voltage electricity into a lower distribution voltage for utility networks, industrial plants, renewable energy projects, commercial buildings and infrastructure facilities.

2. Can the voltage ratio be customized?

Yes. Common configurations include 10kV/0.4kV, 11kV/0.415kV, 13.8kV/0.48kV, 20kV/0.4kV and 33kV/0.415kV. Other voltage ratios can be manufactured according to the project requirements.

3. Is copper winding available?

Yes. Both copper and aluminum windings are available. The selection depends on the required performance, transformer dimensions, operating conditions and project budget.

4. What cooling method is used?

The standard cooling method is ONAN—Oil Natural Air Natural. ONAF cooling with external fans can be provided for special loading or temperature requirements.

5. Can the transformer be installed outdoors?

Yes. The sealed tank, corrosion-resistant coating and weatherproof accessories make it suitable for outdoor installation. Indoor configurations are also available.

6. Is it suitable for high-temperature or coastal environments?

Yes. The transformer can be customized with an enhanced cooling system, high-temperature insulation, sealed terminal boxes, stainless-steel hardware and C4 or C5 anti-corrosion paint.

7. Can it operate at high altitude?

Yes. For installation above 1,000 metres, the insulation clearances, temperature rise and cooling performance will be adjusted according to the actual altitude.

8. Can it be used in solar or wind power projects?

Yes. The transformer can be designed for solar PV, wind power and battery energy-storage projects, including bidirectional power flow, harmonic considerations and project-specific voltage ratios.

9. What standards are available?

The transformer can be manufactured according to IEC 60076, IEEE C57, ANSI, GB or other project-specific standards.

10. What tests are performed before shipment?

Every unit undergoes routine tests, including winding resistance, voltage ratio, vector group, no-load loss, load loss, impedance, insulation and dielectric tests. Tank leakage and accessory functions are also inspected.

11. Can customers witness the factory testing?

Yes. Customer-witnessed Factory Acceptance Testing or third-party inspection can be arranged before shipment.

12. What protection accessories are available?

Available accessories include a Buchholz relay, pressure-relief device, oil-level indicator, oil and winding temperature indicators, sudden-pressure relay, current transformers and remote alarm contacts.

13. What maintenance does the transformer require?

Routine maintenance generally includes checking the oil level, oil condition, bushings, gaskets, connections, protection devices and grounding system. Maintenance intervals depend on the operating environment and loading conditions.

14. How is the transformer packed for export?

The transformer is secured on a reinforced base with protected bushings, sealed openings and moisture-resistant wrapping. Accessories are packed separately in seaworthy wooden cases when necessary.

15. What information is required for a quotation?

Please provide:

  • Rated capacity
  • Primary and secondary voltage
  • Frequency
  • Vector group
  • Winding material
  • Required impedance
  • Tap range
  • Applicable standard
  • Installation altitude
  • Ambient temperature
  • Required accessories
  • Quantity and destination country

16. What is the expected service life?

With correct installation, appropriate loading and regular maintenance, the transformer is typically designed for 25–30 years of operation. Actual service life depends on loading, environmental conditions and maintenance quality.