Search productSearch post

300kVA Three Phase Pad Mounted Transformer
300kVA Three Phase Pad Mounted Transformer
300kVA Three Phase Pad Mounted Transformer
300kVA Three Phase Pad Mounted Transformer

300kVA Three Phase Pad Mounted Transformer

The 300kVA three-phase pad transformer is an efficient and reliable power device designed for commercial, industrial and distribution systems. The transformer provides a high power capacity of 300kVA, which can provide a stable three-phase power supply for high-load equipment, ensuring efficient and smooth operation of the power system. Its sturdy housing adopts a protective design that meets the NEMA 3R standard, which can effectively resist the invasion of the external environment and is suitable for outdoor installation.

Catégorie :

Project Partners

Phone/WhatsApp: 8619131285373

Email: info@zishengtransformer.com
Factory Headquarters: No. 118, Jingyi Street, Economic Development Zone.

*
*
*

Project Stage

Submitting!
Submission successful!
Submission failed!
Incorrect email address!
Incorrect phone number!

Product Description

The 300kVA Three Phase Pad Mounted Transformer is a high-performance outdoor distribution transformer designed for reliable medium-voltage to low-voltage power conversion in utility, commercial, industrial, and renewable energy applications.

Featuring a compact pad-mounted structure, the transformer is installed on a concrete foundation and enclosed in a secure, weather-resistant steel cabinet. This design provides enhanced safety, reduced maintenance requirements, and reliable operation in outdoor environments.

The 300kVA pad mounted transformer is widely used in underground distribution networks, commercial power systems, industrial facilities, solar PV plants, wind farms, and infrastructure projects. It provides stable power supply with excellent energy efficiency, low operating losses, and long service life.

Manufactured using advanced transformer technology and high-quality electrical materials, the transformer can be customized according to IEC, ANSI, IEEE standards and specific EPC project requirements.


Advanced Design & Construction

The 300kVA Three Phase Pad Mounted Transformer adopts an oil-immersed design with ONAN (Oil Natural Air Natural) cooling. The transformer body is installed inside a robust metal enclosure that protects internal components from moisture, dust, corrosion, and mechanical damage.

The transformer core uses high-quality grain-oriented silicon steel with optimized magnetic circuit design to reduce no-load losses and improve energy efficiency.

The winding system is manufactured using high-conductivity copper or aluminum conductors combined with advanced insulation materials. The optimized winding structure provides excellent mechanical strength, thermal stability, and resistance against short-circuit forces.

The sealed tank structure ensures reliable insulation performance, prevents oil leakage, and supports long-term outdoor operation.


Key Features

1. Reliable Power Distribution Performance

The 300kVA pad mounted transformer provides stable and continuous power conversion for medium-voltage distribution systems.

Main advantages:

  • Stable voltage output
  • High operational reliability
  • Excellent overload capability
  • Strong short-circuit withstand performance
  • Long service life

It is suitable for continuous operation in demanding power distribution environments.


2. Safe Pad Mounted Design

The enclosed cabinet design provides additional protection for operators and equipment.

Features include:

  • Outdoor weather-resistant enclosure
  • Secure locking structure
  • Separate high-voltage and low-voltage compartments
  • Safe cable connection system
  • Optional dead-front design

The compact structure makes it ideal for urban areas and locations with limited installation space.


3. Energy Efficient Operation

The transformer adopts advanced low-loss technology to improve overall system efficiency.

Energy-saving features:

  • Low-loss grain-oriented silicon steel core
  • Optimized electromagnetic design
  • Reduced no-load losses
  • Reduced load losses
  • High-quality insulation system

The design helps reduce operating costs throughout the transformer’s service life.


4. Flexible Electrical Configuration

The transformer supports various voltage combinations according to different regional grid systems.

Typical configurations:

  • 11kV / 0.4kV
  • 13.8kV / 0.48kV
  • 15kV / 0.415kV
  • 20kV / 0.4kV
  • 35kV / 0.4kV

Customized voltage ratings are available based on customer requirements.


5. Durable Outdoor Enclosure

The transformer cabinet is manufactured from high-strength steel with corrosion-resistant treatment.

Suitable for:

  • Outdoor substations
  • Coastal environments
  • High humidity areas
  • Industrial sites
  • Harsh weather conditions

Optional coating systems and protection levels are available for special applications.


Main Components

Transformer Core

  • High-quality grain-oriented silicon steel
  • Low magnetic loss design
  • Optimized core structure
  • Improved energy efficiency

Windings

Available options:

  • Copper winding
  • Aluminum winding

Features:

  • High conductivity
  • Excellent thermal performance
  • Strong mechanical strength
  • Reliable insulation performance

Insulation System

Options include:

  • Mineral transformer oil
  • Environmentally friendly insulating fluid

Provides excellent dielectric strength and heat dissipation performance.

Protection Accessories

Optional accessories:

  • High-voltage load break switch
  • High-voltage fuse
  • Surge arrester
  • Low-voltage circuit breaker
  • Pressure relief device
  • Oil level indicator
  • Temperature indicator
  • Remote monitoring system

Manufacturing Process

The 300kVA Three Phase Pad Mounted Transformer is manufactured through strict production procedures:

1. Engineering Design

Technical specifications are reviewed according to project requirements.

2. Core Manufacturing

Precision-cut silicon steel sheets are assembled to ensure low-loss magnetic performance.

3. Coil Winding

Copper or aluminum windings are produced using controlled winding processes.

4. Transformer Assembly

The core, coils, tank, enclosure, and accessories are assembled.

5. Vacuum Oil Filling

High-quality insulating oil is filled under controlled conditions.

6. Testing & Inspection

Complete electrical testing and quality inspection are performed before shipment.


Applications

Renewable Energy Projects

The 300kVA pad mounted transformer is commonly used for:

  • Solar PV power plants
  • Wind farms
  • Battery Energy Storage Systems (BESS)
  • Distributed energy projects

It provides reliable connection between renewable power generation systems and medium-voltage grids.


Utility Distribution Networks

Suitable for:

  • Underground distribution systems
  • Residential communities
  • Urban power networks
  • Utility infrastructure projects

The enclosed structure improves safety and reduces maintenance requirements.


Commercial Applications

Used in:

  • Shopping centers
  • Office buildings
  • Hotels
  • Hospitals
  • Schools
  • Business parks

Providing stable power for commercial electrical loads.


Industrial Applications

Suitable for:

  • Manufacturing plants
  • Mining projects
  • Oil & gas facilities
  • Chemical plants
  • Industrial parks

Supporting motors, production equipment, and industrial power systems.


Infrastructure Projects

Applications include:

  • Water treatment facilities
  • Transportation systems
  • Municipal projects
  • Public facilities

Quality Assurance & Testing

Each 300kVA Three Phase Pad Mounted Transformer undergoes strict factory testing before delivery.

Routine tests include:

  • Winding resistance test
  • Voltage ratio test
  • No-load loss test
  • Load loss test
  • Impedance voltage test
  • Insulation resistance test
  • Applied voltage test
  • Induced voltage test
  • Oil leakage test
  • Appearance inspection

Factory Acceptance Test (FAT) and additional type tests are available for EPC and utility projects.


Why Choose Our 300kVA Pad Mounted Transformer?

✔ Direct transformer manufacturer supply
✔ IEC / ANSI / IEEE standard production capability
✔ Customized voltage and protection solutions
✔ Complete factory testing before shipment
✔ Suitable for EPC and utility applications
✔ Reliable outdoor performance
✔ Professional export support worldwide


The 300kVA Three Phase Pad Mounted Transformer provides a safe, efficient, and flexible power distribution solution for modern electrical networks, renewable energy projects, industrial facilities, and commercial power systems worldwide.

Item Specification
Product Type Three Phase Pad Mounted Transformer
Rated Capacity 300 kVA
Phase Three Phase
Frequency 50Hz / 60Hz
Primary Voltage 6.6kV / 10kV / 11kV / 13.8kV / 15kV / 20kV / 22kV / 33kV / Customized
Secondary Voltage 380V / 400V / 415V / 480V / Customized
Transformer Type Oil-Immersed Pad Mounted Transformer
Cooling Method ONAN (Oil Natural Air Natural)
Installation Type Outdoor Pad Mounted Installation
Winding Material Copper / Aluminum
Core Material Grain-Oriented Silicon Steel
Insulating Medium Mineral Transformer Oil / Eco-Friendly Insulating Fluid
Vector Group Dyn11 / Yyn0 / Customized
Tap Changer Off-Circuit Tap Changer (NLTC)
Tap Range ±2×2.5% / ±5% / Customized
Impedance Voltage Typically 4%–6% (Customized)
No-Load Loss According to IEC / ANSI / IEEE requirements
Load Loss According to IEC / ANSI / IEEE requirements
Insulation Level According to Rated Voltage Class
Temperature Rise According to Applicable Standards
High Voltage Connection Cable Connection / Bushing Connection
Low Voltage Connection Cable Connection / Busbar Connection
High Voltage Protection Load Break Switch / Fuse / Customized
Low Voltage Protection Circuit Breaker / Customized
Surge Protection Surge Arrester (Optional)
Enclosure Material Powder-Coated Steel Cabinet
Enclosure Design Weather-Resistant Outdoor Cabinet
Protection Degree IP54 / IP55 / Customized
Ambient Temperature -25°C to +40°C (Standard)
Altitude ≤1000m (Higher Altitude Available)
Noise Level According to IEC / Customer Requirements
Applicable Standards IEC 60076 / ANSI C57 / IEEE
Service Life 25–30 Years Under Normal Operating Conditions

Standard Accessories

The 300kVA Three Phase Pad Mounted Transformer can be equipped with:

  • High voltage load break switch
  • High voltage fuse
  • Surge arrester
  • Low voltage circuit breaker
  • Oil level indicator
  • Pressure relief device
  • Oil temperature indicator
  • Grounding terminals
  • Drain valve
  • Lifting lugs
  • Nameplate and safety labels

Custom Technical Options

For utility, renewable energy, and EPC projects, the transformer can be customized with:

  • Special MV/LV voltage ratings
  • Copper or aluminum winding design
  • Customized impedance requirements
  • Different vector groups
  • NLTC / OLTC tap changer options
  • Special enclosure dimensions
  • Coastal corrosion protection
  • High-temperature operation design
  • Smart monitoring and communication system
  • IEC / ANSI / IEEE compliance documentation

Final technical parameters can be customized according to local grid conditions, project specifications, installation environment, and customer requirements.

The 300kVA Three Phase Pad Mounted Transformer can be customized to meet different grid requirements, environmental conditions, and project specifications. We provide flexible transformer solutions for utility, renewable energy, industrial, commercial, and EPC projects.

Electrical Configuration

Customized electrical parameters include:

  • Primary and secondary voltage ratings
  • 50Hz / 60Hz frequency selection
  • Copper or aluminum winding options
  • Customized impedance voltage
  • Vector group configuration (Dyn11, Yyn0, etc.)
  • No-load tap changer (NLTC)
  • Customized tap range
  • Special insulation level requirements

Protection & Accessories

The transformer can be equipped with various protection and monitoring devices:

  • High-voltage load break switch
  • High-voltage fuse
  • Surge arrester
  • Low-voltage circuit breaker
  • Pressure relief device
  • Oil level indicator
  • Oil temperature indicator
  • Winding temperature monitor
  • Remote monitoring system
  • Smart transformer monitoring equipment

Enclosure & Mechanical Design

The pad mounted enclosure can be customized according to installation conditions:

  • Dead-front or live-front design
  • Customized cabinet dimensions
  • Outdoor weatherproof enclosure
  • Corrosion-resistant coating system
  • Coastal and high-humidity protection
  • Special cable entry arrangement
  • Customized external color and surface treatment

Insulation & Cooling Options

Available configurations include:

  • Mineral transformer oil
  • Environmentally friendly insulating fluid
  • Enhanced insulation system
  • Special cooling design for high-temperature environments

Standards & Project Documentation

For international projects and EPC requirements, we provide:

  • IEC 60076 compliant design
  • ANSI C57 / IEEE standard options
  • Project-specific technical specifications
  • Engineering drawings
  • Product datasheets
  • Factory Acceptance Test (FAT)
  • Routine test reports
  • Quality certificates
  • Installation and operation manuals

Customized 300kVA Three Phase Pad Mounted Transformer solutions are available to meet different power distribution requirements, ensuring reliable operation and long-term performance in global projects.

The 300kVA Three Phase Pad Mounted Transformer is carefully inspected, protected, and packed before shipment to ensure safe transportation and reliable installation at the project site.

Export Standard Packaging

Before delivery, each transformer undergoes final inspection and preparation, including:

  • Complete appearance and quality inspection
  • Protection of bushings, terminals, and external accessories
  • Moisture-proof and dust-proof protection
  • Secure fixing to prevent movement during transportation
  • Export-standard packing suitable for international shipment

Transportation Preparation

The transformer is designed for safe long-distance transportation by:

  • Sea freight
  • Road transportation
  • Rail transportation

Professional packing methods help protect the transformer against vibration, impact, humidity, and harsh transportation conditions.

Technical Documents

Each shipment can be supplied with complete documentation, including:

  • Product specification sheet
  • Nameplate information
  • Routine test reports
  • Factory Acceptance Test (FAT) documents (if required)
  • Quality certificates
  • Installation and operation manuals
  • Packing list

Global Delivery Support

We provide comprehensive export support for overseas customers and EPC projects, including:

  • Container loading arrangement
  • Shipping coordination
  • Export documentation support
  • Delivery tracking assistance

Every 300kVA Three Phase Pad Mounted Transformer is carefully handled from factory to project site to ensure safe arrival, easy installation, and reliable operation after commissioning.

Each 300kVA Three Phase Pad Mounted Transformer undergoes strict quality control and comprehensive testing throughout the manufacturing process to ensure reliable electrical performance, safety, and long-term operation.

All tests are performed according to IEC 60076, ANSI C57, IEEE standards, and customer-specific project requirements.

Factory Testing Procedures

1. Winding Resistance Test

The resistance of transformer windings is measured to verify:

  • Winding conductor quality
  • Internal connection reliability
  • Manufacturing accuracy
  • Consistent electrical performance

2. Voltage Ratio Test

The transformer turns ratio is tested to confirm:

  • Correct voltage conversion
  • Tap changer operation
  • Phase relationship
  • Compliance with design specifications

3. No-Load Loss & Excitation Current Test

This test evaluates transformer core performance by measuring:

  • Core loss
  • No-load current
  • Magnetic circuit performance
  • Energy efficiency characteristics

4. Load Loss & Impedance Voltage Test

The transformer is tested under rated load conditions to verify:

  • Load loss values
  • Impedance voltage
  • Thermal performance
  • Electrical parameter accuracy

5. Insulation Resistance Test

The insulation system is checked between:

  • High-voltage winding and low-voltage winding
  • Windings and ground
  • Internal components and enclosure

This ensures safe operation and reliable insulation performance.


6. Applied Voltage Test

The transformer insulation strength is tested under specified voltage conditions to ensure the insulation system can withstand electrical stress during operation.


7. Induced Voltage Test

This test verifies the internal insulation system and confirms the transformer’s ability to withstand abnormal voltage conditions.


8. Oil Quality & Leakage Test

The transformer tank and sealing system are inspected to ensure:

  • No oil leakage
  • Proper sealing performance
  • Reliable insulation protection
  • Long-term outdoor operation capability

9. Mechanical & Appearance Inspection

Before shipment, each transformer is carefully inspected for:

  • Enclosure structure
  • Painting quality
  • Nameplate information
  • Terminal arrangement
  • Protection accessories
  • Overall manufacturing quality

Factory Acceptance Test (FAT)

For EPC contractors, utilities, and large-scale power projects, a Factory Acceptance Test (FAT) can be arranged before shipment.

FAT services include:

  • Customer witness inspection
  • Test procedure verification
  • Performance data review
  • Quality document confirmation

Available documents:

  • Routine test reports
  • Quality certificates
  • Technical drawings
  • Material certificates
  • Inspection records

Through strict manufacturing control and testing procedures, every 300kVA Three Phase Pad Mounted Transformer is delivered with verified quality, stable performance, and dependable operation for global power distribution applications.

Every 300kVA Three Phase Pad Mounted Transformer undergoes complete routine testing before shipment to verify electrical performance, safety, and compliance with international standards.

Routine tests are carried out according to IEC 60076, ANSI C57, IEEE standards and customer project specifications.

Standard Routine Tests Include:

1. Winding Resistance Measurement

The resistance of each transformer winding is measured to verify:

  • Conductor quality
  • Winding connection reliability
  • Manufacturing consistency
  • Correct assembly process

2. Voltage Ratio & Phase Displacement Test

This test confirms:

  • High-voltage and low-voltage ratio accuracy
  • Tap position performance
  • Phase displacement
  • Correct transformer configuration

3. No-Load Loss & Excitation Current Test

Measures transformer performance under no-load conditions, including:

  • Core loss
  • Excitation current
  • Magnetic circuit performance
  • Energy efficiency characteristics

4. Load Loss & Impedance Voltage Test

Evaluates transformer performance under rated operating conditions:

  • Load loss measurement
  • Impedance voltage verification
  • Electrical parameter confirmation
  • Operating efficiency assessment

5. Insulation Resistance Test

Checks insulation performance between:

  • High-voltage winding and low-voltage winding
  • Windings and ground
  • Electrical components and enclosure

Ensures safe and stable operation.


6. Applied Voltage Test

Verifies the dielectric strength of the insulation system and ensures the transformer can withstand specified electrical stresses.


7. Induced Voltage Test

Tests internal insulation performance and confirms reliable operation under different voltage conditions.


8. Oil Leakage Test

The transformer tank, sealing system, and accessories are inspected to ensure:

  • No oil leakage
  • Proper sealing performance
  • Reliable insulation protection

9. Final Assembly & Appearance Inspection

Before delivery, each transformer is checked for:

  • Cabinet structure
  • Surface coating quality
  • Nameplate details
  • Terminal connections
  • Accessories installation
  • Overall workmanship

Testing Documentation

Complete testing documents can be provided with each transformer shipment, including:

  • Routine test reports
  • Electrical performance records
  • Quality certificates
  • Inspection documents

Additional inspection services and customer witness testing are available for EPC projects, utility applications, and international power distribution projects.

Strict routine testing ensures every 300kVA Three Phase Pad Mounted Transformer meets project requirements and provides safe, stable, and reliable operation throughout its service life.

The 300kVA Three Phase Pad Mounted Transformer is designed for safe and reliable medium-voltage to low-voltage power distribution in a wide range of applications. With its compact structure, weather-resistant enclosure, and flexible configuration options, it is an ideal solution for utility networks, renewable energy projects, industrial facilities, commercial buildings, and infrastructure developments.


Renewable Energy Projects

The 300kVA pad mounted transformer is widely used in renewable energy systems to connect distributed power generation sources with medium-voltage distribution networks.

Typical applications include:

  • Solar PV power plants
  • Wind farms
  • Battery Energy Storage Systems (BESS)
  • Distributed energy generation projects

It provides stable voltage conversion, efficient power transmission, and reliable operation for clean energy infrastructure.


Utility Distribution Networks

The transformer is suitable for modern power distribution systems requiring safe and efficient outdoor installation.

Applications include:

  • Underground distribution networks
  • Residential communities
  • Urban power supply systems
  • Utility substations
  • Rural electrification projects

The enclosed pad mounted design improves safety, reduces maintenance requirements, and supports long-term reliable operation.


Commercial Buildings

The 300kVA pad mounted transformer provides dependable power supply for various commercial facilities.

Common applications include:

  • Office buildings
  • Shopping centers
  • Hotels
  • Schools
  • Hospitals
  • Business parks

It supports lighting systems, HVAC equipment, elevators, and other critical electrical loads.


Industrial Facilities

Designed for demanding industrial environments, the transformer provides stable power distribution for production and manufacturing operations.

Suitable for:

  • Manufacturing plants
  • Industrial parks
  • Mining facilities
  • Oil & gas projects
  • Chemical plants
  • Processing factories

It supplies reliable electricity for motors, production equipment, automation systems, and auxiliary facilities.


Infrastructure Projects

The compact outdoor design makes the transformer suitable for various public and infrastructure applications.

Used in:

  • Water treatment plants
  • Transportation facilities
  • Municipal projects
  • Public buildings
  • Construction sites

Data Centers & Critical Power Applications

For facilities requiring high power reliability, the 300kVA pad mounted transformer can be integrated into medium-voltage distribution systems for:

  • Data centers
  • Communication facilities
  • Critical infrastructure
  • Backup power systems

Optional monitoring and protection solutions help improve system reliability and operational safety.


The 300kVA Three Phase Pad Mounted Transformer provides a safe, efficient, and customizable power distribution solution for utilities, EPC contractors, renewable energy developers, industrial users, and commercial projects worldwide.

1. What is a 300kVA Three Phase Pad Mounted Transformer?

A 300kVA Three Phase Pad Mounted Transformer is an outdoor distribution transformer designed to convert medium-voltage power into low-voltage electricity for end users. It is installed on a concrete pad and protected by a weather-resistant enclosure, making it suitable for utility, commercial, industrial, and renewable energy applications.


2. What voltage ratings are available for the 300kVA pad mounted transformer?

The primary and secondary voltage ratings can be customized according to local grid conditions and project requirements.

Common configurations include:

  • 11kV / 0.4kV
  • 13.8kV / 0.48kV
  • 15kV / 0.415kV
  • 20kV / 0.4kV
  • 35kV / 0.4kV

Other voltage combinations are available upon request.


3. Can the transformer be customized according to project requirements?

Yes. We provide customized solutions based on customer specifications, including:

  • Rated voltage
  • Frequency (50Hz / 60Hz)
  • Copper or aluminum winding
  • Vector group
  • Impedance
  • Tap range
  • Protection devices
  • Enclosure design
  • Accessories and monitoring systems

4. Is the 300kVA pad mounted transformer suitable for outdoor installation?

Yes. The transformer is designed for outdoor operation with a durable steel enclosure that provides protection against:

  • Rain
  • Dust
  • Humidity
  • Corrosion
  • Temperature variations

Special designs are available for coastal areas and harsh environments.


5. What cooling method is used for the 300kVA transformer?

The standard cooling method is ONAN (Oil Natural Air Natural), which uses natural circulation of insulating oil and air for heat dissipation.

Alternative cooling solutions can be customized for special applications.


6. What winding materials are available?

The transformer can be manufactured with:

  • Copper windings — offering excellent conductivity, high efficiency, and strong electrical performance.
  • Aluminum windings — providing a cost-effective solution for distribution applications.

7. What protection accessories can be installed?

Optional protection and monitoring components include:

  • High-voltage load break switch
  • High-voltage fuse
  • Surge arrester
  • Low-voltage circuit breaker
  • Pressure relief device
  • Oil level indicator
  • Temperature indicator
  • Remote monitoring system

8. What standards does the transformer comply with?

The transformer can be manufactured according to:

  • IEC 60076
  • ANSI C57
  • IEEE standards

Customized standards are also available according to customer requirements.


9. What tests are performed before shipment?

Each transformer undergoes complete factory testing, including:

  • Winding resistance test
  • Voltage ratio test
  • No-load loss test
  • Load loss test
  • Impedance voltage test
  • Insulation resistance test
  • Applied voltage test
  • Induced voltage test
  • Oil leakage inspection
  • Appearance inspection

Complete test reports can be provided for quality verification.


10. Can you provide Factory Acceptance Test (FAT)?

Yes. FAT can be arranged for EPC contractors, utilities, and large-scale projects.

FAT services include:

  • Customer witness inspection
  • Test procedure verification
  • Performance data review
  • Quality document confirmation

11. What information is required for a quotation?

To provide an accurate quotation, please provide:

  • Rated capacity: 300kVA
  • Primary voltage
  • Secondary voltage
  • Frequency
  • Installation environment
  • Required standards
  • Protection requirements
  • Quantity
  • Delivery destination

Our engineering team will recommend the most suitable transformer configuration according to your project requirements.


12. What are the advantages of choosing a pad mounted transformer?

Compared with traditional distribution transformers, pad mounted transformers provide:

  • Safer enclosed structure
  • Better outdoor protection
  • Lower maintenance requirements
  • Compact installation
  • Flexible configuration options
  • Reliable long-term operation

The 300kVA Three Phase Pad Mounted Transformer is a reliable and customizable solution for modern power distribution systems, supporting global utility, industrial, commercial, and renewable energy projects.

300kVA Three Phase Pad Mounted Transformer300kVA Three Phase Pad Mounted Transformer

Click on the inquiry